1

Design of Resonant Current Controller in Full stationary-frame for LCL-based Active Front-end Converter

Hu, Shang-hung 26 July 2010 (has links)
Thanks to development of power semiconductor devices and integrated circuits, active front-end converters with controllability of bidirectional power flow have become popular and viable in industrial applications. This thesis proposes an improved resonant current control for the active front-end converter with LCL filter. The proposed control consists of a band-pass filter tuned at fundamental frequency and various band-rejected filters resonant at harmonic frequencies to provide fundamental current tracking capability as well as enhance harmonic current rejection. Based on this algorithm, the active front-end converter can control dc voltage with unity power factor by sensing converter output current, LCL filter voltage and dc voltage. This approach also conducts harmonic current rejection under distorted line voltage with no phase-locked-loop used, which is the significant advantage in terms of phase lag of frame transformation and computing effort of digital signal processing. Current tracking performance and harmonic rejection capability of the proposed method are verified based on frequency-domain analysis. Computer simulations and experimental results are also implemented to validate effectiveness.
2

Transformer fault-recovery inrush currents in MMC-HVDC systems and mitigation strategies

Vaheeshan, Jeganathan January 2017 (has links)
The UK Government has set an ambitious target to achieve 15% of final energy consumption from renewable sources by 2020. High Voltage Direct Current (HVDC) technology is an attractive solution for integrating offshore wind power farms farther from the coast. In the near future, more windfarms are likely to be connected to the UK grid using HVDC links. With the onset of this fairly new technology, new challenges are inevitable. This research is undertaken to help assist with these challenges by looking at possibilities of problems with respect to faster AC/DC interaction modes, especially, on the impact of inrush currents which occur during fault-recovery transients. In addition to that, possible mitigation strategies are also investigated. Initially, the relative merits of different transformer models are analysed with respect to inrush current transient studies. The most appropriate transformer model is selected and further validated using field measurement data. A detailed electro-magnetic-transient (EMT) model of a grid-connected MMC-HVDC system is prepared in PSCAD/EMTDC to capture the key dynamics of fault-recovery transformer inrush currents. It is shown that the transformer in an MMC system can evoke inrush currents during fault recovery, and cause transient interactions with the converter and the rest of the system, which should not be neglected. It is shown for the first time through a detailed dynamic analysis that if the current sensors of the inner-current control loops are placed at the converter-side of the transformer instead of the grid-side, the inrush currents will mainly flow from the grid and decay faster. This is suggested as a basic remedial action to protect the converter from inrush currents. Afterwards, analytical calculations of peak flux-linkage magnitude in each phase, following a voltage-sag recovery transient, are derived and verified. The effects of zero-sequence currents and fault resistance on the peak flux linkage magnitude are systematically explained. A zero-sequence-current suppression controller is also proposed. A detailed study is carried out to assess the key factors that affect the maximum peak flux-linkage and magnetisation-current magnitudes, especially with regard to fault specific factors such as fault inception angle, duration and fault-current attenuation. Subsequently, the relative merits of a prior-art inrush current mitigation strategy and its implementation challenges in a grid-connected MMC converter are analysed. It is shown that the feedforward based auxiliary flux-offset compensation scheme, as incorporated in the particular strategy, need to be modified with a feedback control technique, to alleviate the major drawbacks identified. Following that, eight different feedback based control schemes are devised, and a detailed dynamic and transient analysis is carried out to find the best control scheme. The relative merits of the identified control scheme and its implementation challenges in a MMC converter are also analysed. Finally, a detailed EMT model of an islanded MMC-HVDC system is implemented in PSCAD/EMTDC and the impacts of fault-recovery inrush currents are analysed. For that, initially, a MMC control scheme is devised in the synchronous reference frame and its controllers are systematically tuned. To obtain an improved performance, an equivalent control scheme is derived in the stationary reference frame with Proportional-Resonant controllers, and incorporated in the EMT model. Following that, two novel inrush current mitigation strategies are proposed, with the support of analytical equations, and verified.
3

Repetitive Control Of A Three-phase Uninterruptible Power Supply With Isolation Transformer

Cetinkaya, Suleyman 01 January 2007 (has links) (PDF)
A repetitive control method for output voltage control of a three phase uninterruptible power supply (UPS) with isolation transformer is investigated. In the method voltage control loop is employed in the stationary dq frame. The controller eliminates the periodic errors on the output voltages due to inverter voltage nonlinearity and load disturbances. The controller design and implementation details are given. The controller is implemented on a 5-kVA UPS prototype which is constructed in laboratory. Linear and nonlinear loads for balanced and unbalanced load operating conditions are considered. The steady-state and dynamic performance of the control method are investigated in detail. The theory of the control strategy is verified by means of simulations and experiments.
4

Output Voltage Control Of A Four-leg Inverter Based Three-phase Ups By Means Of Stationary Frame Resonant Filter Banks

Demirkutlu, Eyyup 01 January 2007 (has links) (PDF)
A method for high performance output voltage control of a four-leg inverter based three-phase transformerless UPS is proposed. Voltage control loop is employed and the method employs stationary frame resonant filter controllers for the fundamental and harmonic frequency components. A capacitor current feedback loop provides active damping and enhances the output voltage dynamic performance. The controller design and implementation details are given. Linear and nonlinear loads for balanced and unbalanced load operating conditions are considered. The steadystate and dynamic performance of the UPS are investigated in detail. A scalar PWM method with implementation simplicity and high performance is proposed and implemented. The control and PWM methods are proven by means of theory, simulations, and experiments.