Spelling suggestions: "subject:"steadystate fluorescence"" "subject:"steadystate fluorescence""
11 |
Charakterizace koloidních částic pomocí deprotonace v excitovaném stavu za použití pokročilých fluorescenčních technik / Characterization of coloid particles by excited-state proton transfer with advanced fluorescence techniquesKotouček, Jan January 2016 (has links)
The deprotonation characteristics of fluorescent probes -naphthol and 8-hydroxypyrene-1,3,6-trisulphonic acid (HPTS) were studied in this diploma thesis, using steady-state and time-resolved fluorescence spectroscopy. Two cationic surfactants, Septonex and cetyltrimethylammonium bromide (CTAB), were studied. These surfactants were measured in the complex with hyaluronan (1.75 MDa, 1 MDa and 300 kDa). Steady-state fluorescence was used for determination of critical aggregation concentration of each surfactant and pKa*. Time-resolved fluorescence decays were used to calculate the average lifetimes and the deprotonation constants of naphthol and HPTS. The measurement with hyaluronan were compared with the polystyrenesulfonate (PSS) – surfactant system. The effect of hydration shell of hyaluronan on hyaluronan – surfactant complex formation results from the comparison of above mentioned systems. Large differences were found in the deprotonation characteristic between surfactants and even between individual molecular weights of hyaluronan. The measurement shows that the hydration shell is located near to the dissociated carboxyl groups of hyaluronan chain, where the interaction with the positively charged surfactants occurs. Furthermore, the aggregation number of Septonex was determined by quenching of pyrene using cetylpyridinium chloride (CPC) as a quencher. The aggregation number for 20 mM Septonex solution was determined as a value of 104 molecules. CPC was used for confirmation of the localization of -naphthol in the micelles of CTAB and polymer – CTAB, respectively.
|
12 |
Časově rozlišená fluorescence systémů polymer-tenzid / Time-resolved fluorescence of system polymer-surfactantMondek, Jakub January 2012 (has links)
In this diploma thesis was studied time-resolved fluorescence in polymer-surfactant system. At first aggregation numbers of cationic (cetyltrimethylammonium bromide), anionic (sodium dodecylsulfate) and nonionic (Triton X-100) surfactants were studied by steady-state and time-resolved fluorescence spectroscopy. These two methods were compared. Aggregation numbers by steady-state method were always lower than aggregation numbers measured by time-resolved method. Steady-state method of determination aggregation numbers is useless for surfactants with high aggregation number and for aerated samples. Addition of hyaluronan to surfactant system was studied. There was observed change in aggregation number after addition of hyaluronan and change in percentage of dynamic quenching after addition of hyaluronan. Hyaluronan affected aggregation number of cetyltrimethylammonium bromide and Triton X-100. Hyaluronan increased percentage of dynamic quenching in cetyltrimethylammonium bromide and in Triton X-100. Pyren in sodium dodecylsulfate was quenched by sphere of action with negligible percentage of dynamic quenching and addition of hyaluronan had no effect on quenching. As next goal of this thesis, the determination of the position of fluorescence probe pyrene in cetyltrimethylammonium bromide, sodium dodecylsulfate and Triton X-100 micelles was chosen. Position of pyrene changed with charge and structure of micelles. Next was studied how percentage of dynamic quenching by iodide compounds changes with different charge of micelle. In all cases majority of dynamic quenching was calculated.
|
Page generated in 0.0593 seconds