• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 202
  • 43
  • 26
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 378
  • 378
  • 81
  • 45
  • 38
  • 33
  • 28
  • 26
  • 26
  • 22
  • 21
  • 20
  • 19
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Occupational stress in professional groups

Esworthy, Ann January 1987 (has links)
No description available.
22

Structural and biochemical analysis of a small heat shock protein, Hsp26, from Saccharomyces cerevisiae

Bentley, Nicola Jane January 1991 (has links)
No description available.
23

The measurement of finger tremor in man

Wharrad, H. J. January 1982 (has links)
No description available.
24

Some experiments concerning the interaction between noise exposure and glucose loading upon psychophysiological state

Mackay, C. J. January 1980 (has links)
No description available.
25

Variation in mood, adrenal 'stress' hormone levels with blood pressure associated with everyday working experience in a British population

Pollard, Tessa M. January 1993 (has links)
No description available.
26

An analysis of the effect of vibration on the human stretch reflex : studies with sinusoidal stretching in cat and man

Watson, J. D. G. January 1981 (has links)
No description available.
27

The cardiac stress of badminton participation

Huntington, George Edward 03 June 2011 (has links)
There is no abstract available for this thesis.
28

Ratings of perceived exertion and pain in the assessment and prescription of exercise

Buckley, John Paul January 2002 (has links)
No description available.
29

Thermographic studies of tissue trauma and seating

Black, Robin Charles January 1984 (has links)
Wheelchair sitters with insensitive skin have a high risk of developing pressure sores. Prolonged pressure produces ischaemic conditions in the underlying tissues which may lead to cellular death and necrosis. Properly designed seating may reduce this risk and prevent the onset of pressure sores. To achieve the best protection possible a method of objective evaluation is required which will account for variations in tissue quality, sitting behaviour and sitting biomechanics. This thesis reports on the application of thermography into a tissue trauma seating programme and the quantification of isotherm areas for statistical comparisons of skin temperature response to experimental parameters. The thermographic research is presented in three phases of analysis: Chapter 4, a retrospective study of thermograms based on maximum temperatures; Chapter 5 both maximum temperatures from the real-time thermograph display and automatically collected areameter isotherm area data; and Chapter 6, a prospective patient study based on isotherm area data. During the preliminary stages of research, patients were followed with thermographic examinations at various stages of fitting and trial sitting on wheelchair cushions. There followed a series of tests with able-bodied subjects on experimental seats in an environmental chamber to determine the minimum conditions required for quantitative measurement of thermographic data. The examination room at the Ontario Crippled Children's Centre was then modified accordingly for patient studies and quantitative techniques were tested further. The results of these three phases of reseach are presented with recommendations for continuing studies. The acquired information supports the use of thermography in tissue trauma programmes. Sites of accumulated stress were found to be identifiable and approaches tor the quantitative comparison of thermal response to sate and unsafe loading conditions presented. Maximum temperatures were the most sensitive measures of hyperthermic response and mean imaged temperatures, the most readily characterized for cooling. Detailed discrimination of differences in skin cooling were found to be enhanced when the area of examination was minimized.
30

Physiological changes in urinary and salivary electrolytes due to physical activity in warm environments

Shamssain, Mohammad H. January 1981 (has links)
Changes in heart rate; oral temperature; mean skin temperature; urinary pH, volume, sodium, potassium, chloride, urea and creatinine; salivary pH, sodium, potassium and urea; expired air and oxygen consumption have been monitored in young men doing ( 1) exercise on an ergometer for 4 min at 10C, 20C, 30C and 40C dry bulb 50% rh at 120-320 W; (2) 20 min at 30C dry bulb at 50% rh, 60% rh, and 85% rh at 120W, 145W and 170W; and (3) 60 min at 20C, 30C and 40C dry bulb and 50% rh at 170w. Changes in work rate, environmental temperature, relative humidity and exposure time were found to correlate well with the urinary and salivary changes and in most cases changes in both work rate and ambient temperature produced simple summation effects. The increase in salivary components correlated well with the decrease in urinary components. Salivary sodium, potassium and Na+/K+ ratio increased significantly when work intensity, exposure time and environmental temperature were increased. Salivary urea correlates significantly with increased exposure time. The elevated values for salivary components may be explained on the basis of volatilization caused by forced ventilation during exercise; increased penetration of plasma components into saliva; increased water reabsorption, decreased sodium reabsorption, and increased potassium secretion in the ductile system of the salivary glands due to increased sympathetic activity. The results show that changes in saliva give a valid indication of the body's response to work and environmental stress and suggest that saliva could be used to study the combined effects of work and heat in places where it is impracticable to obtain samples of blood or urine.

Page generated in 0.2195 seconds