Spelling suggestions: "subject:"superficial""
1 |
Rychlá separace výbušnin vysokoúčinnou kapalinovou chromatografií / Fast separation of explosives by high performance liquid chromatographyŠesták, Jozef January 2011 (has links)
The topic of the diploma thesis is fast separation of explosives by HPLC and development of miniaturized liquid chromatograph for application in a handheld explosives detection device. In this work the retention of some nitrated explosives and selectivity in reversed phase system as a function of mobile phase composition is studied while methanol, acetonitrile and acetone as an organic solvent is used. Best selectivity and good retention can be observed in methanol mobile phase. Acetonitrile and acetone are not suitable for fast isocratic separation of mixture containing pentaerythritol tetranitrate because of its strong retention. Efficiency and permeability of monolithic column (Chromolith CapRod RP-18e) and columns filled with superficially porous particles are compared (Kinetex 2,6 µm C-18, Poroshell 120 SB-C18). Monolithic column with satisfying efficiency and high column permeability is the most suitable solution for fast separation of explosives. Assuming use of explosives detection device in different conditions the separation was optimized on temperature 50 °C. Under these conditions the 35% v/v methanol gives good retention and selectivity. For very fast scan analysis of pentaerythritol tetranitrate or other nitroaromatics use of 70% v/v acetone mobile phase is suitable. Construction of miniaturized liquid chromatograph that enables preconcentration of explosives from aqueous solutions and fast separation in less than 1 minute is described. This concept will be incorporated into the handheld explosives detection device where the explosives vapor will be absorbed into the water and after the separation detected by chemiluminescence.
|
2 |
Colunas empacotadas em cromatografia líquida capilar: desenvolvimento de hardwares e avaliação de suas contribuições no desempenho cromatográfico / Packed columns for capillary liquid chromatography: hardware development and evaluation of its contribution to the chromatography performanceBorsatto, João Victor Basolli 27 July 2018 (has links)
Essa dissertação de mestrado descreve o desenvolvimento de hardwares de colunas para cromatografia líquida capilar. O processo de desenvolvimentos desses dispositivos é descrito gradativamente e os pontos fortes e as limitações de cada modelo de hardware são discutidos. O melhor modelo de hardware desenvolvido apresentou produção simples, fácil conexão ao sistema cromatográfico e resistência a pressões superiores a 900 bar. Sucessivamente ao estabelecimento de um modelo de hardware apropriado, os efeitos dos materiais do hardware na eficiência das colunas foram avaliados. Poucos estudos relatam a influência do hardware nas separações em escala capilar, de forma que essa dissertação contribui para o preenchimento dessa lacuna. Capilares de aço inoxidável e sílica fundida e frits de aço inoxidável e fibra de vidro foram avaliados. Colunas com eficiências superiores a 100.000 pratos por metro foram produzidas. / This master\'s dissertation describes the development of hardware for capillary liquid chromatography columns. The development process of the devices is described gradually and the strengths and limitations of each model of hardware are discussed. The best-developed hardware model presented easy production, practice connection to the chromatographic system and resistance to pressures greater than 900 bar. After the establishment of an appropriate hardware model, the effects of hardware materials on the efficiency of the columns were evaluated. Few studies report the influence of the hardware on capillary scale separations; therefore, this dissertation contributes to fill this gap. Capillaries of stainless steel and fused silica and frits of stainless steel and glass fiber were evaluated. Columns with efficiencies greater than 100,000 plates per meter were produced.
|
3 |
Colunas empacotadas em cromatografia líquida capilar: desenvolvimento de hardwares e avaliação de suas contribuições no desempenho cromatográfico / Packed columns for capillary liquid chromatography: hardware development and evaluation of its contribution to the chromatography performanceJoão Victor Basolli Borsatto 27 July 2018 (has links)
Essa dissertação de mestrado descreve o desenvolvimento de hardwares de colunas para cromatografia líquida capilar. O processo de desenvolvimentos desses dispositivos é descrito gradativamente e os pontos fortes e as limitações de cada modelo de hardware são discutidos. O melhor modelo de hardware desenvolvido apresentou produção simples, fácil conexão ao sistema cromatográfico e resistência a pressões superiores a 900 bar. Sucessivamente ao estabelecimento de um modelo de hardware apropriado, os efeitos dos materiais do hardware na eficiência das colunas foram avaliados. Poucos estudos relatam a influência do hardware nas separações em escala capilar, de forma que essa dissertação contribui para o preenchimento dessa lacuna. Capilares de aço inoxidável e sílica fundida e frits de aço inoxidável e fibra de vidro foram avaliados. Colunas com eficiências superiores a 100.000 pratos por metro foram produzidas. / This master\'s dissertation describes the development of hardware for capillary liquid chromatography columns. The development process of the devices is described gradually and the strengths and limitations of each model of hardware are discussed. The best-developed hardware model presented easy production, practice connection to the chromatographic system and resistance to pressures greater than 900 bar. After the establishment of an appropriate hardware model, the effects of hardware materials on the efficiency of the columns were evaluated. Few studies report the influence of the hardware on capillary scale separations; therefore, this dissertation contributes to fill this gap. Capillaries of stainless steel and fused silica and frits of stainless steel and glass fiber were evaluated. Columns with efficiencies greater than 100,000 plates per meter were produced.
|
4 |
Desenvolvimento de diferentes métodos LC-MS/MS para a determinação de fármacos e endocanabinóides em amostras de plasma / Development of different LC-MS/MS methods for the determination of drugs and endocannabinoids in plasma samplesAcquaro Junior, Vinicius Ricardo 06 April 2018 (has links)
Esta tese foi dividida em três capítulos. O capítulo I descreve o desenvolvimento do método Column switching UHPLC-MS/MS para a determinação simultaneamente de fármacos psicotrópicos em amostras de plasma de pacientes esquizofrênicos. A politerapia é uma prática comum no tratamento da esquizofrenia. Portanto, a monitorização terapêutica destes fármacos tem sido realizada para o ajuste das doses e individualização da terapia farmacológica. O método Column switching UHPLC-MS/MS apresentou linearidade na faixa de concentração de 0,025 a 1,25 ng mL-1 com R2 acima de 0,9950 e a falta de teste de ajuste (p > 0,05); precisão com coeficientes de variação inferiores a 12% e exatidão com erro padrão relativo inferior a 14%. Este método foi aplicado com sucesso para determinação de fármacos em amostras de plasma de pacientes esquizofrênicos para fins de monitorização terapêutica. No capítulo II, o desempenho cromatográfico de colunas C18 superficialmente e totalmente porosas com diferentes tamanhos de partícula foi avaliado para a análise de fármacos psicotrópicos por LC-MS/MS e LC-DAD. Com o sistema LC-MS/MS foram avaliados os seguintes parâmetros cromatográficos: altura do prato reduzido vs velocidade linear reduzida, impedância vs velocidade linear reduzida, tempo da corrida cromatográfica vs vazão, pressão vs vazão, resolução, capacidade de pico, assimetria e fator de retenção. Já com o sistema LC-DAD foram avaliados a hidrofobicidade, atividade silanol e impurezas metálicas também foram avaliadas. As colunas com superfície carregada apresentaram maior eficiência cromatográfica para os fármacos em sua forma ionizada. Já as colunas com partículas menores que 2 µm (Cortecs 1,6 µm, Acquity 1,7 µm, e Kinetex 1,7 µm) apresentaram maior eficiência cromatográfica para os fármacos na forma parcialmente ionizada. Os modelos matemáticos gerados foram capazes de prever a pressão e o tempo da corrida cromatográfica em diferentes vazões para todas as colunas. Considerando a eficiência, impedância, resolução, capacidade de pico, fator de retenção e hidrofobicidade, as colunas Cortecs 1,6 µm e Acquity 1,7 µm apresentaram melhor desempenho durante a análise dos fármacos em amostra de plasma. O capítulo III descreve o desenvolvimento e validação dos métodos SPME-UHPLC-MS/MS e Bio-SPME-Nano-ESI-MS/MS para a determinação dos endocanabinóides (AEA e 2-AG) em amostras biológicas. Para a otimização do processo SPME foram avaliadas as fases SPME (C18, C30 e HLB) e os solventes para dessorção (metanol, acetonitrila e isopropanol). Os aditivos modificadores de matriz, como cloridrato de guanidina, ácido trifluoroacético e acetonitrila foram avaliados por planejamento experimental. Os métodos SPME-UHPLC-MS/MS e Bio-SPME-Nano-ESI-MS/MS, com a fase HLB biocompatível, apresentaram para ambos endocanabinóides valores de LOQs de 1 ng mL-1 e 50 ng mL-1, respectivamente. O método Bio-SPME-Nano-ESI-MS/MS permitiu o direto acoplamento da fibra SPME ao espectrômetro de massas via dessorção/ionização nanoeletrospray que resultou em rápida determinação quantitativa dos endocanabinóides em amostras biológicas. / This thesis is divided into three chapters. Chapter I describes the development of a column switching UHPLCMS/MS method to determine psychotropic drugs in schizophrenic patients plasma samples simultaneously. Polytherapy is a common practice in schizophrenia treatment. Therefore, therapeutic drug monitoring has been applied to adjust doses and to customize pharmacological therapy. The column switching UHPLCMS/MS method developed here is linear at concentrations ranging from 0.025 to 1.25 ng mL-1 with R2 above 0.9950 and presents lack of fit test (p > 0.05), precision with coefficients of variation lower than 12%, and accuracy with relative standard error lower than 14%. This method was successfully applied to determine drugs in schizophrenic patients plasma samples for therapeutic drug monitoring. In chapter II, the chromatographic performance of C18 superficially porous columns and of C18 fully porous columns with different particle sizes were evaluated for analysis of psychotropic drugs by LC-MS/MS and LC-DAD. Within the LC-MS/MS system, the following chromatographic parameters were assessed: reduced plate height vs reduced linear velocity, impedance vs reduced linear velocity, chromatographic run time vs flow rate, backpressure vs flow rate, resolution, peak capacity, asymmetry, and retention factor. Within the LC-DAD system, hydrophobicity, silanol activity, and metal impurities were also examined. Columns with charged surface displayed improved chromatographic efficiency for drugs in the ionized form. Columns with particles smaller than 2 µm (Cortecs 1.6 µm, Acquity 1.7 µm, and Kinetex 1.7 µm) presented higher chromatographic efficiency for the drugs, which were in their partially ionized form. The generated mathematical models were able to predict the backpressure and the chromatographic run time at different flow rates for all the columns. Considering efficiency, impedance, resolution, peak capacity, retention factor, and hydrophobicity, columns Cortecs 1.6 µm and Acquity 1.7 µm provided the best performance during analysis of drugs in plasma samples. Chapter III describes the development and validation of the SPME-UHPLC-MS/MS and the Bio-SPME-Nano-ESI-MS/MS methods for determination of endocannabinoids (AEA and 2-AG) in biological samples. To optimize the SPME process, SPME coatings (C18, C30, and HLB) and solvents for desorption (methanol, acetonitrile, and isopropanol) were evaluated. Matrix modifier additives, such as guanidine hydrochloride, trifluoroacetic acid, and acetonitrile, were assessed by experimental design. The SPME-UHPC-MS/MS and the Bio-SPME-Nano-ESI-MS/MS methods with HLB biocompatible coating provided LOQ values of 1 ng mL-1 and 50 ng mL-1, respectively, for both endocannabinoids. The Bio-SPME-Nano-ESI-MS/MS method allowed direct coupling of SPME fibers to the mass spectrometer by desorption/ionization nanoelectrospray, which resulted in rapid quantitative determinations of endocannabinoids in biological samples.
|
5 |
Desenvolvimento de diferentes métodos LC-MS/MS para a determinação de fármacos e endocanabinóides em amostras de plasma / Development of different LC-MS/MS methods for the determination of drugs and endocannabinoids in plasma samplesVinicius Ricardo Acquaro Junior 06 April 2018 (has links)
Esta tese foi dividida em três capítulos. O capítulo I descreve o desenvolvimento do método Column switching UHPLC-MS/MS para a determinação simultaneamente de fármacos psicotrópicos em amostras de plasma de pacientes esquizofrênicos. A politerapia é uma prática comum no tratamento da esquizofrenia. Portanto, a monitorização terapêutica destes fármacos tem sido realizada para o ajuste das doses e individualização da terapia farmacológica. O método Column switching UHPLC-MS/MS apresentou linearidade na faixa de concentração de 0,025 a 1,25 ng mL-1 com R2 acima de 0,9950 e a falta de teste de ajuste (p > 0,05); precisão com coeficientes de variação inferiores a 12% e exatidão com erro padrão relativo inferior a 14%. Este método foi aplicado com sucesso para determinação de fármacos em amostras de plasma de pacientes esquizofrênicos para fins de monitorização terapêutica. No capítulo II, o desempenho cromatográfico de colunas C18 superficialmente e totalmente porosas com diferentes tamanhos de partícula foi avaliado para a análise de fármacos psicotrópicos por LC-MS/MS e LC-DAD. Com o sistema LC-MS/MS foram avaliados os seguintes parâmetros cromatográficos: altura do prato reduzido vs velocidade linear reduzida, impedância vs velocidade linear reduzida, tempo da corrida cromatográfica vs vazão, pressão vs vazão, resolução, capacidade de pico, assimetria e fator de retenção. Já com o sistema LC-DAD foram avaliados a hidrofobicidade, atividade silanol e impurezas metálicas também foram avaliadas. As colunas com superfície carregada apresentaram maior eficiência cromatográfica para os fármacos em sua forma ionizada. Já as colunas com partículas menores que 2 µm (Cortecs 1,6 µm, Acquity 1,7 µm, e Kinetex 1,7 µm) apresentaram maior eficiência cromatográfica para os fármacos na forma parcialmente ionizada. Os modelos matemáticos gerados foram capazes de prever a pressão e o tempo da corrida cromatográfica em diferentes vazões para todas as colunas. Considerando a eficiência, impedância, resolução, capacidade de pico, fator de retenção e hidrofobicidade, as colunas Cortecs 1,6 µm e Acquity 1,7 µm apresentaram melhor desempenho durante a análise dos fármacos em amostra de plasma. O capítulo III descreve o desenvolvimento e validação dos métodos SPME-UHPLC-MS/MS e Bio-SPME-Nano-ESI-MS/MS para a determinação dos endocanabinóides (AEA e 2-AG) em amostras biológicas. Para a otimização do processo SPME foram avaliadas as fases SPME (C18, C30 e HLB) e os solventes para dessorção (metanol, acetonitrila e isopropanol). Os aditivos modificadores de matriz, como cloridrato de guanidina, ácido trifluoroacético e acetonitrila foram avaliados por planejamento experimental. Os métodos SPME-UHPLC-MS/MS e Bio-SPME-Nano-ESI-MS/MS, com a fase HLB biocompatível, apresentaram para ambos endocanabinóides valores de LOQs de 1 ng mL-1 e 50 ng mL-1, respectivamente. O método Bio-SPME-Nano-ESI-MS/MS permitiu o direto acoplamento da fibra SPME ao espectrômetro de massas via dessorção/ionização nanoeletrospray que resultou em rápida determinação quantitativa dos endocanabinóides em amostras biológicas. / This thesis is divided into three chapters. Chapter I describes the development of a column switching UHPLCMS/MS method to determine psychotropic drugs in schizophrenic patients plasma samples simultaneously. Polytherapy is a common practice in schizophrenia treatment. Therefore, therapeutic drug monitoring has been applied to adjust doses and to customize pharmacological therapy. The column switching UHPLCMS/MS method developed here is linear at concentrations ranging from 0.025 to 1.25 ng mL-1 with R2 above 0.9950 and presents lack of fit test (p > 0.05), precision with coefficients of variation lower than 12%, and accuracy with relative standard error lower than 14%. This method was successfully applied to determine drugs in schizophrenic patients plasma samples for therapeutic drug monitoring. In chapter II, the chromatographic performance of C18 superficially porous columns and of C18 fully porous columns with different particle sizes were evaluated for analysis of psychotropic drugs by LC-MS/MS and LC-DAD. Within the LC-MS/MS system, the following chromatographic parameters were assessed: reduced plate height vs reduced linear velocity, impedance vs reduced linear velocity, chromatographic run time vs flow rate, backpressure vs flow rate, resolution, peak capacity, asymmetry, and retention factor. Within the LC-DAD system, hydrophobicity, silanol activity, and metal impurities were also examined. Columns with charged surface displayed improved chromatographic efficiency for drugs in the ionized form. Columns with particles smaller than 2 µm (Cortecs 1.6 µm, Acquity 1.7 µm, and Kinetex 1.7 µm) presented higher chromatographic efficiency for the drugs, which were in their partially ionized form. The generated mathematical models were able to predict the backpressure and the chromatographic run time at different flow rates for all the columns. Considering efficiency, impedance, resolution, peak capacity, retention factor, and hydrophobicity, columns Cortecs 1.6 µm and Acquity 1.7 µm provided the best performance during analysis of drugs in plasma samples. Chapter III describes the development and validation of the SPME-UHPLC-MS/MS and the Bio-SPME-Nano-ESI-MS/MS methods for determination of endocannabinoids (AEA and 2-AG) in biological samples. To optimize the SPME process, SPME coatings (C18, C30, and HLB) and solvents for desorption (methanol, acetonitrile, and isopropanol) were evaluated. Matrix modifier additives, such as guanidine hydrochloride, trifluoroacetic acid, and acetonitrile, were assessed by experimental design. The SPME-UHPC-MS/MS and the Bio-SPME-Nano-ESI-MS/MS methods with HLB biocompatible coating provided LOQ values of 1 ng mL-1 and 50 ng mL-1, respectively, for both endocannabinoids. The Bio-SPME-Nano-ESI-MS/MS method allowed direct coupling of SPME fibers to the mass spectrometer by desorption/ionization nanoelectrospray, which resulted in rapid quantitative determinations of endocannabinoids in biological samples.
|
Page generated in 0.074 seconds