1 |
Study and evaluation of correction factors applied to ionization chambers in radiotherapy photon beams / Estudo e avaliação de fatores de correção aplicados a câmaras de ionização em feixes de fótons radioterápicos.Reis, Cristiano Queiroz Melo dos 30 July 2015 (has links)
The use of a beam quality correction factor,kQ, is needed in dosimetry of radiotherapy beams for correcting differences between chamber responses at the calibration beam quality, Q0 and at the quality beam of the user, Q. The purpose of this study is to determine the beam quality correction factor for the NE2571 ionization chamber widely used in radiotherapy and its dependence with the stopping-power and the chamber perturbation factors. In addition, an investigation of the use of parallel plate chambers for determining surface doses in photon beams is also performed using the EGSrnc Monte Carlo code system. Results obtained with PENELOPE show that simulations with phase-space files appropriately scored can be up to ten times shorter than using a full spectrum in the input-file. Values of kQ, and its components show good agreement with published values in the literature and are provided with typical statistical uncertainties of 0.2%. Values of kQ and absorbed dose to water conversion factors obtained with egs_chamber user code for parallel plate chambers are also provided with maximum statistical uncertainty of 0.7%. Therefore, the results obtained are expected to contribute with improving dosimetry protocols and the quality of life of radiotherapy patients. / O uso de uma fator de correção para a qualidade do feixe, kQ, é necessário em dosimetria de feixes radioterápicos para a correçãoo das diferenças entre a resposta de câmaras de ionização nas qualidades do feixe de calibração, Q0 e do usuário Q. O propósito deste trabalho consiste em determinar o fator de correção da qualidade de feixe para a câmara de ionização NE2571 amplamente utilizada em radioterapia e sua dependência com o stopping-power e os fatores de perturbação da câmara. Além disso, uma investigação do uso de câmaras de placas paralelas para determinar doses na superfície em feixes de fótons é também realizada usando o sistem de códigos em Monte Carlo EGSnrc. Resultados obtidos com o PENELOPE mostram que simulações usando phase-space, podem ser cerca de dez vezes menos longa do que simula ções usando um espectro completo no arquivo de entrada. Valores de kQ e suas componentes mostraram boa concordncia com dados publicados na literatura e são fornecidos com incertezas estatísticas típicas de 0.2%. Valores de kQ e fatores de conversão pra dose absorvida na água obtidos para as câmaras de placas paralelas com o código de usuário egs_chamber são também fornecidos com incerteza estatística máxima de 0.7%. Deste modo, espera-se que os resultados obtidos possam contribuir com o aperfeiçoamento de protocolos de dosimetria e com a qualidade de vida de pacientes radioterpicos.
|
2 |
Study and evaluation of correction factors applied to ionization chambers in radiotherapy photon beams / Estudo e avaliação de fatores de correção aplicados a câmaras de ionização em feixes de fótons radioterápicos.Cristiano Queiroz Melo dos Reis 30 July 2015 (has links)
The use of a beam quality correction factor,kQ, is needed in dosimetry of radiotherapy beams for correcting differences between chamber responses at the calibration beam quality, Q0 and at the quality beam of the user, Q. The purpose of this study is to determine the beam quality correction factor for the NE2571 ionization chamber widely used in radiotherapy and its dependence with the stopping-power and the chamber perturbation factors. In addition, an investigation of the use of parallel plate chambers for determining surface doses in photon beams is also performed using the EGSrnc Monte Carlo code system. Results obtained with PENELOPE show that simulations with phase-space files appropriately scored can be up to ten times shorter than using a full spectrum in the input-file. Values of kQ, and its components show good agreement with published values in the literature and are provided with typical statistical uncertainties of 0.2%. Values of kQ and absorbed dose to water conversion factors obtained with egs_chamber user code for parallel plate chambers are also provided with maximum statistical uncertainty of 0.7%. Therefore, the results obtained are expected to contribute with improving dosimetry protocols and the quality of life of radiotherapy patients. / O uso de uma fator de correção para a qualidade do feixe, kQ, é necessário em dosimetria de feixes radioterápicos para a correçãoo das diferenças entre a resposta de câmaras de ionização nas qualidades do feixe de calibração, Q0 e do usuário Q. O propósito deste trabalho consiste em determinar o fator de correção da qualidade de feixe para a câmara de ionização NE2571 amplamente utilizada em radioterapia e sua dependência com o stopping-power e os fatores de perturbação da câmara. Além disso, uma investigação do uso de câmaras de placas paralelas para determinar doses na superfície em feixes de fótons é também realizada usando o sistem de códigos em Monte Carlo EGSnrc. Resultados obtidos com o PENELOPE mostram que simulações usando phase-space, podem ser cerca de dez vezes menos longa do que simula ções usando um espectro completo no arquivo de entrada. Valores de kQ e suas componentes mostraram boa concordncia com dados publicados na literatura e são fornecidos com incertezas estatísticas típicas de 0.2%. Valores de kQ e fatores de conversão pra dose absorvida na água obtidos para as câmaras de placas paralelas com o código de usuário egs_chamber são também fornecidos com incerteza estatística máxima de 0.7%. Deste modo, espera-se que os resultados obtidos possam contribuir com o aperfeiçoamento de protocolos de dosimetria e com a qualidade de vida de pacientes radioterpicos.
|
Page generated in 0.0535 seconds