1 |
Parametric Average-Value Model of Rectifiers in Brushless Excitation SystemsQunais, Thaer 01 January 2013 (has links)
An average-value model of a rotating rectifier circuit in a brushless excitation system is set forth, where a detailed simulation is required to extract the essential averaged-model parameters using numerical averaging. In the proposed approach, a synchronous machine model with saturation and cross saturation and an arbitrary rotor network representation that uses a voltage-behind-reactance representation for the field winding of the main machine is proposed. This allows the field winding to be represented as branches in a circuit solver, permitting straightforward simulation with connected circuitry. Also a brushless exciter model is introduced to be compatible with the averaged-model, where the exciter armature windings are represented using a voltage-behind-reactance formulation. The resulting average-value model is verified in time domain against detailed simulation, and its validity is demonstrated in all rectifier modes of operation.
|
2 |
Voltage Stability and Control in Autonomous Electric Power Systems with Variable FrequencyRosado, Sebastian Pedro 19 November 2007 (has links)
This work focuses on the safe and stable operation of an autonomous power system interconnecting an AC source with various types of power electronic loads. The stability of these systems is a challenge due to the inherent nonlinearity of the circuits involved. Traditionally, the stability analysis in this type of power systems has been approached by means of small-signal methodology derived from the Nyquist stability criterion. The small-signal analysis combined with physical insight and the adoption of safety margins is sufficient, in many cases, to achieve a stable operation with an acceptable system performance. Nonetheless, in many cases, the margins adopted result in conservative measures and consequent system over designs.
This work studies the system stability under large-perturbations by means of three different tools, namely parameter space mapping, energy functions, and time domain simulations. The developed parameters space mapping determines the region of the state and parameter space where the system operation is locally stable. In this way stability margins in terms of physical parameters can be established. Moreover, the boundaries of the identified stability region represent bifurcations of the system where typical nonlinear behavior appears. The second approach, based on the Lyapunov direct method, attempts to determine the region of attraction of an equilibrium point, defined by an operation condition. For this a Lyapunov function based on linear matrix inequalities was constructed and tested on a simplified autonomous system model. In Addition, the third approach simulates the system behavior on a computer using a detailed system model. The higher level of model detail allows identifying unstable behavior difficult to observe when simpler models are used.
Because the stability of the autonomous power system is strongly associated with the characteristics of the energy source, an improved voltage controller for the generator is also presented. The generator of an autonomous power system must provide a good performance under a wide variety of regimes. Under these conditions a model based controller is a good solution because it naturally adapts to the changing requirements. To this extent a controller based on the model of a variable frequency synchronous generator has been developed and tested. The results obtained show a considerable improvement performance when compared to previous practices. / Ph. D.
|
3 |
A New Paradigm for Large Brushless Hydrogenerators : Advantages Beyond the Static SystemNøland, Jonas Kristiansen January 2017 (has links)
The grid code, FIKS, from the Norwegian transmission system operator (TSO), Statnett, states that synchronous generators > 25MVA, must have a static excitation system. However, an improved brushless excitation system is in operation on some commercial power plants (36MVA, 93.75rpm & 52MVA, 166.67rpm) with grid-assisting performance beyond the conventional static system. The convenional diode bridge is replaced with a remote-controlled thyristor bridge on the shaft. If wireless communication is not allowed, a control signal through brushes should be employed instead. The thesis explores the expected new era for large brushless hydrogenerators. The proposed brushless system have benefits of reduced regular maintenance due to elimination of brushes and reduced unscheduled maintenance due to redundancy; causing a redused cost-of-energy. A six-phase exciter design with a hybrid-mode thyristor bridge interface leads to improved fault-tolerance, better controllability, minimized torque pulsations and reduced armature currents of the exciter. Excitation boosting (EB) capability is included in the brushless system without additional components or circuitry, contrary to the static excitation system. The brushless excitation system is made insensitive to voltage dips in the interconnected grid, causing improved fault ride-through (FRT) capability and power system stabilizer (PSS) actions.
|
Page generated in 0.1431 seconds