• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação Experimental do Desempenho de Protótipo de Medidor de Vazão para Óleos Pesados Por Tecnologia Ultrassônica Por Tempo de Trânsito

ABOUJAOUDE, F. 18 December 2017 (has links)
Made available in DSpace on 2018-03-22T15:51:24Z (GMT). No. of bitstreams: 1 tese_11637_FADY ABOUJAOUDE .pdf: 42298478 bytes, checksum: fa8b54eaf1878ccba2132f35dfd67c06 (MD5) Previous issue date: 2017-12-18 / A medição ultrassônica por tempo de trânsito vem sendo utilizado cada vez mais nos últimos anos, havendo, sem dúvida, a necessidade urgente de desenvolvimento de tecnologia brasileira neste campo da instrumentação. Este trabalho se dedica ao estudo de medição de vazão em óleos pesados por ultrassom com a pretensão de verificar experimentalmente a validade dos processos estatísticos utilizados visando a redução das incertezas nas leituras. Para isso o trabalho analisa experimentalmente efeitos de possíveis erros do medidor por tempo de trânsito validando-os em relação a um medidor de vazão de referência. Medidor Ultrassônico, tempo de trânsito, óleo pesado, medição de vazão
2

Avaliação da dinâmica normal da circulação do meio de contraste em estruturas vasculares nos exames de tomografia computadorizada das artérias coronárias

Morato, Tiago Nóbrega January 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015. / Submitted by Cristiane Mendes (mcristianem@gmail.com) on 2015-07-07T19:15:02Z No. of bitstreams: 1 2015_TiagoNobregaMorato.pdf: 275774 bytes, checksum: 53d29410be3596461f972180faf17305 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2015-07-08T19:08:55Z (GMT) No. of bitstreams: 1 2015_TiagoNobregaMorato.pdf: 275774 bytes, checksum: 53d29410be3596461f972180faf17305 (MD5) / Made available in DSpace on 2015-07-08T19:08:55Z (GMT). No. of bitstreams: 1 2015_TiagoNobregaMorato.pdf: 275774 bytes, checksum: 53d29410be3596461f972180faf17305 (MD5) / Introdução: O uso de agentes de contraste intravenoso é corriqueiro em pacientes submetidos à tomografia computadorizada (TC) de tórax. Sabe-se que o tempo de trânsito de contraste (TTC) do sítio de injeção até a circulação sistêmica tem relação com o débito cardíaco e pode trazer importantes informações funcionais, pouco estudadas até o momento. Objetivos: Medir o TTC entre o tronco pulmonar e aorta ascendente em exames de TC de artérias coronárias de pacientes saudáveis, definindo padrões de normalidade para estes tempos de circulação. Métodos: Pacientes ambulatoriais sadios encaminhados para realização de TC de artérias coronárias arrolados de forma consecutiva. Os TTC entre o sítio de injeção e a veia cava superior, tronco pulmonar e aorta ascendente foram medidos com base nas imagens de monitorização (bolus tracking). O débito cardíaco foi calculado a partir das imagens da TC pelo método geométrico e correlacionado com os TTC. Resultados: Foram analisados 18 pacientes. O TTC médio entre a artéria pulmonar e a aorta ascendente foi de 6,8 ± 1,6s. Não houve correlação significativa entre o TTC na circulação pulmonar e o débito cardíaco medido pelo método geométrico. Conclusão: O valor de normalidade do TTC entre a artéria pulmonar e aorta ascendente foi estabelecido, servindo de base para avaliação clínica. / Introduction: The use of contrast agents is a common radiological practice in chest tomography (CT) examinations. It’s known that the transit time of the contrast agent (TTC) between the injection site and the systemic circulation is related to the cardiac output and can add important functional information. Nevertheless, there is little information regarding the normal transit times. Objectives: Measure the TTC between main pulmonary artery and ascending aorta in coronary artery CT’s of healthy patients, defining the normality values for such circulatory times. Methods: Healthy ambulatorial patients who underwent coronary artery CT were included. The TTC’s between the injection site and inferior vena cava, main pulmonary artery and ascending aorta were measured using the bolus tracking images. The cardiac output was measured from the CT images using the geometric method. Results: 18 patients were included in the analysis. The mean TTC between the mean pulmonary artery and aorta was 6,8 ± 1,6s. There was no significant correlation between the TTC and cardiac output measured by the geometric method. Conclusion: The normal value for the TTC between main pulmonary artery and ascending aorta was determined, and can be used as a reference for future publications.
3

Modelamento e correção de descentralização das imagens de tempo de trânsito

FISCHETTI, Anna Carmela January 2003 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-11-17T12:23:15Z No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_ModelamentoCorrecaoDescentralizacao.pdf: 1000871 bytes, checksum: 9e13030d31de4a03b7be9f569ee09e76 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-11-17T13:30:40Z (GMT) No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_ModelamentoCorrecaoDescentralizacao.pdf: 1000871 bytes, checksum: 9e13030d31de4a03b7be9f569ee09e76 (MD5) / Made available in DSpace on 2014-11-17T13:30:40Z (GMT). No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_ModelamentoCorrecaoDescentralizacao.pdf: 1000871 bytes, checksum: 9e13030d31de4a03b7be9f569ee09e76 (MD5) Previous issue date: 2003 / ANP - Agência Nacional do Petróleo / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / As imagens da parede do poço obtidas através da ferramenta UBI (Ultrasonic Borehole Imager) são amplamente utilizadas por geólogos e engenheiros de petróleo para identificar eventos geológicos nas paredes de poços abertos e na inspeção dos tubos de revestimento, uma vez que este perfil praticamente fornece uma fotografia da parede do poço. As ferramentas de imageamento acústico produzem imagens do tempo de trânsito e da amplitude do pulso acústico gerado pela ferramenta e refletido na parede do poço. Entretanto, estas imagens podem ter uma interpretação não realista, uma vez que elas podem ter seu aspecto alterado em razão do movimento da ferramenta no interior do poço. Este trabalho apresenta o modelamento das imagens de tempo de trânsito a partir da aplicação do critério de Coulomb para a ruptura da parede do poço submetida a um estado plano de tensões, a qual fornecerá a seção do poço, que é a forma geométrica que será traçada pela ferramenta de imageamento acústico do poço. O deslocamento ascensional da ferramenta e as imperfeições da parede do poço, normalmente, são os responsáveis pelo deslocamento da posição do transdutor em relação ao eixo do poço. Este efeito pode ter grande responsabilidade nas imperfeições das imagens de tempo de trânsito. Assim, a correção dessas imagens, chamada de correção da descentralização, busca o reposicionamento do transdutor para a posição do eixo do poço. Apresenta-se, também, um método de correção do efeito da descentralização da ferramenta baseado neste modelamento. O método é proposto com base na geometria analítica plana e no método do raio para a definição do tempo de trânsito do pulso acústico, com o objetivo de reconstruir as imagens de tempo de trânsito obtidas com a ferramenta descentralizada, ou seja, corrigir estas imagens tornando-as como se fossem obtidas com a ferramenta centralizada em relação ao eixo do poço. / The imaging tools used to borehole wall features identification have been largely utilized by geologist and oil engineers to identify geological events in a open hole and inspect the casing tube. The acoustic borehole imaging tools generate a transit time image and an acoustic amplitude image that are used to this proposes. However those logs may have a non-realist interpretation, since some tools effect can negatively influence in the images appearance. This paper presents a transit time image model starting from the application of the Coulomb’s approach to the borehole wall rupture submitted to a plane state of tensions which will supply the borehole section that is the geometric form that will be mapped by the acoustic borehole imaging toll. The tool up displacement and the borehole wall imperfections are usually the responsible for the transducer displacement in relation to the borehole axis. This effect may have important responsibility in the acoustic images imperfections. Thus, a computational process of transducer repositioning in the borehole axis position obtains the correction of those images, called decentralization correction. A method of tool decentralization effect correction is presented too based on this model which is proposed based on the plane analytic geometry and in the ray method to the definition of the transit time of the acoustic pulse, with the objective of reconstruct the transit time images achieved by the decentralized tool, that is to say, correct these images becoming as they were achieved by the centralized tool in relation to the borehole axis.

Page generated in 0.1715 seconds