Spelling suggestions: "subject:"centrodes"" "subject:"textron""
1 |
Sensor-Based Garments that Enable the Use of Bioimpedance Technology : Towards PersonalizedHealthcare Monitoring.Marquez Ruiz, Juan Carlos January 2013 (has links)
Functional garments for physiological sensing purposes have been utilized in several disciplinesi.e. sports, firefighting, military and medical. In most of the cases textile electrodes (Textrodes)embedded in the garment are employed to monitor vital signs and other physiologicalmeasurements. Electrical Bioimpedance (EBI) is a non-invasive and effective technology that canbe used for detection and supervision of different health conditions. In some specific applicationssuch as body composition assessment EBIS has shown encouraging results proving good degreeof effectiveness and reliability. In a similar way Impedance Cardiography (ICG) is anothermodality of EBI primarily concerned with the determination of Stroke Volume SV, indices ofcontractility, and other aspects of hemodynamics.EBI technology in the previously mentioned modalities can benefit from a integration with agarment; however, a successful implementation of EBI technology depends on the goodperformance of textile electrodes. The main weakness of Textrodes is a deficient skin-electrodeinterface which produces a high degree of sensitivity to signal disturbances. This sensitivity canbe reduced with a suitable selection of the electrode material and an intelligent and ergonomicgarment design that ensures an effective skin-electrode contact area.This research work studies the performance of textile electrodes and garments for EBIspectroscopy for Total Body Assessment and Transthoracic Electrical Bioimpedance (TEB) forcardio monitoring. Their performance is analyzed based on impedance spectra, estimation ofparameters, influence of electrode polarization impedance Zep and quality of the signals using asreference Ag/AgCl electrodes. The study includes the analysis of some characteristics of thetextile electrodes such as conductive material, skin-electrode contact area size and fabricconstruction.The results obtained in this research work present evidence that textile garments with a dry skinelectrodeinterface like the ones used in research produce reliable EBI measurements in bothmodalities: BIS for Total Body Assessment and TEB for Impedance Cardiography. Textiletechnology, if successfully integrated, may enable the utilization of EBI in both modalities andconsequently implementing wearable applications for home and personal health monitoring. / <p>QC 20121213</p>
|
2 |
Textile-enabled Bioimpedance Instrumentation for Personalised Health Monitoring ApplicationsFerreira Gonzalez, Javier January 2013 (has links)
A growing number of factors, including the costs, technological advancements, an ageing population, and medical errors are leading industrialised countries to invest in research on alternative solutions to improving their health care systems and increasing patients’ life quality. Personal Health System (PHS) solutions envision the use of information and communication technologies that enable a paradigm shift from the traditional hospital-centred healthcare delivery model toward a preventive and person-centred approach. PHS offers the means to follow patient health using wearable, portable or implantable systems that offer ubiquitous, unobtrusive bio-data acquisition, allowing remote access to patient status and treatment monitoring.Electrical Bioimpedance (EBI) technology is a non-invasive, quick and relatively affordable technique that can be used for assessing and monitoring different health conditions, e.g., body composition assessments for nutrition. EBI technology combined with state-of-the-art advances in sensor and textile technology are fostering the implementation of wearable bioimpedance monitors that use functional garments for the implementation of personalised healthcare applications.This research studies the development of a portable EBI spectrometer that can use dry textile electrodes for the assessment of body composition for the purposes of clinical uses. The portable bioimpedance monitor has been developed using the latest advances in system-on-chip technology for bioimpedance spectroscopy instrumentation. The obtained portable spectrometer has been validated against commercial spectrometer that performs total body composition assessment using functional textrode garments.The development of a portable Bioimpedance spectrometer using functional garments and dry textile electrodes for body composition assessment has been shown to be a feasible option. The availability of such measurement systems bring closer the real implementation of personalised healthcare systems. / 2013-04-29 Licentiatseminarium kl.10-11.30 The presentation will be broadcast using Adobe Connect. For more information contact javier.ferreira@hb.se
|
3 |
Textile-enabled Bioimpedance Instrumentation for Personalised Health Monitoring ApplicationsFerreira Gonzalez, Javier January 2013 (has links)
A growing number of factors, including the costs, technological advancements, an ageing population, and medical errors are leading industrialised countries to invest in research on alternative solutions to improving their health care systems and increasing patients’ life quality. Personal Health System (PHS) solutions envision the use of information and communication technologies that enable a paradigm shift from the traditional hospital-centred healthcare delivery model toward a preventive and person-centred approach. PHS offers the means to follow patient health using wearable, portable or implantable systems that offer ubiquitous, unobtrusive bio-data acquisition, allowing remote access to patient status and treatment monitoring. Electrical Bioimpedance (EBI) technology is a non-invasive, quick and relatively affordable technique that can be used for assessing and monitoring different health conditions, e.g., body composition assessments for nutrition. EBI technology combined with state-of-the-art advances in sensor and textile technology are fostering the implementation of wearable bioimpedance monitors that use functional garments for the implementation of personalised healthcare applications. This research studies the development of a portable EBI spectrometer that can use dry textile electrodes for the assessment of body composition for the purposes of clinical uses. The portable bioimpedance monitor has been developed using the latest advances in system-on-chip technology for bioimpedance spectroscopy instrumentation. The obtained portable spectrometer has been validated against commercial spectrometer that performs total body composition assessment using functional textrode garments. The development of a portable Bioimpedance spectrometer using functional garments and dry textile electrodes for body composition assessment has been shown to be a feasible option. The availability of such measurement systems bring closer the real implementation of personalised healthcare systems. / <p>QC 20130405</p>
|