• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Design and Optimization of an Ultrasound System for Two Photon Microscopy Studies of Ultrasound and Microbubble Assisted Blood-brain Barrier Disruption

Drazic, Jelena 27 May 2011 (has links)
In vivo real-time data of ultrasound and microbubble assisted blood-brain barrier disruption is centrally based on low-resolution magnetic resonance images. Additional information can be gained using online microscopic monitoring. This study presents the first ever in vivo two-photon microscopy, four-dimensional data sets of ultrasound and microbubble assisted blood-brain barrier disruption. It characterized the threshold pressures and mechanical index needed to disrupt the vasculature with 800 kHz ultrasound, and found three different leakage constants from the compromised vasculature. Furthermore, using numerical models, an ultrasound array was designed and optimized to perform specifically with our two-photon microscope. It was fabricated, fully characterized, and its performance met both the required pressure field profile and the pressure values needed for our in vivo two-photon microscopy experiments. This array is an important step in microscopically characterizing ultrasound and microbubble assisted blood-brain barrier disruption.
2

Design and Optimization of an Ultrasound System for Two Photon Microscopy Studies of Ultrasound and Microbubble Assisted Blood-brain Barrier Disruption

Drazic, Jelena 27 May 2011 (has links)
In vivo real-time data of ultrasound and microbubble assisted blood-brain barrier disruption is centrally based on low-resolution magnetic resonance images. Additional information can be gained using online microscopic monitoring. This study presents the first ever in vivo two-photon microscopy, four-dimensional data sets of ultrasound and microbubble assisted blood-brain barrier disruption. It characterized the threshold pressures and mechanical index needed to disrupt the vasculature with 800 kHz ultrasound, and found three different leakage constants from the compromised vasculature. Furthermore, using numerical models, an ultrasound array was designed and optimized to perform specifically with our two-photon microscope. It was fabricated, fully characterized, and its performance met both the required pressure field profile and the pressure values needed for our in vivo two-photon microscopy experiments. This array is an important step in microscopically characterizing ultrasound and microbubble assisted blood-brain barrier disruption.

Page generated in 0.1051 seconds