• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 3
  • Tagged with
  • 16
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Processing of toughened cyanate ester matrix composites

Rau, Anand V. 06 June 2008 (has links)
This investigation explored the feasibility of recently developed toughened cyanate ester networks as candidate materials for high performance composite matrix applications. The resin investigated was a Bisphenol-A cyanate ester toughened with hydroxy functionalized phenolphthalein based amorphous poly(arylene ether sulfone). The thermoplastic modified toughened networks exhibited improvement in the fracture toughness over the base cyanate ester networks without significant reductions in mechanical properties or glass transition temperature. Void free, unidirectional carbon fiber prepreg was successfully manufactured with the toughened cyanate resin using a solventless hot-melt technique. The resin mass fraction of the prepregs was between 31 and 35%. The carbon fiber, toughened cyanate ester prepreg was fabricated into composite panels for mechanical and physical testing. The cure cycle used to manufacture the composite laminates was developed with the aid of a process simulation model developed by Loos and Springer. In order to accurately simulate the resin curing and flow processes, the cure reaction kinetics and melt viscosity was characterized as a function of temperature and degree of cure and input into the simulation model. The model generated cure cycle was used in the manufacture 8-ply unidirectional and 16-ply quasi-isotropic composite laminates. The manufactured laminates were well consolidated to the specified fiber volume fraction between 59 and 60%. Photomicrographs showed that the laminates are void free, the fiber and resin distribution is uniform and fiber wet-out is very good. Mechanical tests were performed to measure the impact damage resistance and shear properties of the toughened cyanate ester resin composites. The results show improvements in impact damage resistance compared with the commonly used hot-melt epoxy resin composites. The influence of processing on performance was observed from the results of shear tests. Carbon fabric composite panels were manufactured by liquid molding processes (resin transfer molding and resin film infusion), with a series of four toughened cyanate ester resins generated by varying the concentration and the molecular weight of the toughener. The panels were subjected to physical, damage tolerance, and fracture toughness tests. The results of physical testing indicate consistently uniform quality, and the void content was found to be less than 2%. The toughened cyanate ester composites exhibited significantly improved impact damage resistance and tolerance compared with hot-melt epoxy systems. Marked increase in the mode II fracture toughness were observed with an increase in the concentration and the molecular weight of the toughener. / Ph. D.
12

Friction and lubrication behaviour of metal-on-metal and ZTA ceramic-on-CFR PEEK hip prostheses : friction and lubrication behaviour of metal-on-metal hip resurfacing and ZTA ceramic heads versus CFR PEEK cups with various diameters and clearances using serum-based lubricants with various viscosities

Said, Assma Musbah January 2012 (has links)
The natural hip joint in healthy people has a very low friction with very little (or no) wear. It works as a dynamically loaded bearing and is subjected to about 1-2 million cycles of loading per year. The applied load is the body weight which is tripled when walking and even higher during other activities such as running and jumping. Unfortunately these joints are not always healthy due to various causes such as fractures or disease leading to severe pain which necessitates joint replacement. Currently, the orthopaedic industries are working towards developing an ideal artificial hip joint with low wear, low friction, good lubrication, better fixation/stability and biocompatibility. Many different designs and materials have been investigated with some promising new implants which can be used depending on patients' individual need (large or small joint), activity and age. In this work, two types of artificial hip joints were tested for friction and lubrication studies: Metal-on-Metal (MoM) Biomet hip resurfacing ReCaps with large diameters (>35-60 mm) and different diametral clearances (~ 60-350 µm), and Zirconia Toughened Alumina (ZTA) heads against carbon-fibre-reinforced poly-ether-ether ketone (CFR PEEK) cups with different diameters (>35-60 mm) and diametral clearances (60-1860 µm). Seven serum-based lubricants with different viscosities were used with and without carboxy methyl cellulose (CMC) additions as gelling agent to increase viscosity depending on the CMC content. The maximum load applied was 2000 N for the stance phase with a minimum load of 100 N for the swing phase. A Pro-Sim friction hip simulator was used to investigate the frictional torque generated between the articulating surfaces so as the friction factor can be calculated. Stribeck analysis was then employed to assess the mode of lubrication. For the metal-on-metal hip resurfacing joints, the friction factors were in the range 0.03-0.151 and those for the ZTA ceramic heads versus CFR PEEK cups were in the range 0.006-0.32. Stribeck analyses showed mainly mixed lubrication for both MoM and ZTA ceramic-on-CFR PEEK joints. The experimental results were in agreement with most of the theoretical calculations suggesting mixed lubricating regimes at low viscosities and moving on to fluid film lubrication at higher viscosities. Joints with larger-diameters, lower clearances and lower surface roughness exhibited a higher lambda ratio suggesting improved lubrication. Viscosity flow curves for the serum-based lubricants having viscosity ≤ 0.00524 Pas showed non-linear relationship between viscosity and shear rate indicating non-Newtonian flow with pseudoplastic or shear-thinning characteristic, i.e. viscosity decreased as shear rate increased up to shear rates of ~ 1000 s⁻¹. However, at shear rates greater than 1000 s⁻¹ Newtonian flow became dominant with almost constant viscosity, i.e. a linear relationship between shear stress and shear rate. On the other hand, viscosity flow curves for the lubricants with viscosity ≥ 0.0128 Pas showed non-Newtonian behaviour up to a shear rate of 3000 s⁻¹ with shear-thinning characteristic.
13

Friction and lubrication behaviour of hip resurfacing metal-on-metal and ZTA ceramic on CFR peek implants with various diameters and clearances : friction and lubrication behaviour of hip resurfacing Co-Cr-Mo and zirconia toughened alumina ceramic heads against carbon fibre reinforced poly-ether-ether-ketone cups with various diameters and clearances have been investigated using serum-based lubricants

Ehmaida, Mutyaa M. January 2012 (has links)
Total hip joint prostheses made of CoCrMo heads versus ultra high molecular weight polyethylene (UHMWPE) cups have a limited lifetime, mainly due to the wear of the UHMWPE cups as a result of high friction between the articulating surfaces leading to osteolysis and implant loosening with revision surgery becoming inevitable in more active patients. Tribology plays an important role in developing the design, minimizing wear and reducing friction of hip joint prostheses in order to improve their long-term performance, with good lubricating properties. Metal-on-metal hip resurfacing prostheses have shown significantly lower wear rates compared with conventional metal-on-polyethylene implants and thus osteolysis is potentially reduced leading to increased lifetime of the prosthesis. Nevertheless, excessive wear of metal-on-metal joints leads to metal ion release, causing pseudo-tumours and osteolysis. An alternative approach to such bearings is the use of newly developed carbon fiber-reinforced poly-ether-ether-ketone (CFR PEEK) acetabular cups articulating against ceramic femoral heads due to their better wear resistance compared to UHMWPE. In this study, therefore, friction and lubrication properties of large diameter, as cast, Co-Cr-Mo metal-on-metal hip resurfacing implants with various diameters and clearances have been investigated and compared to those of the newly developed zirconia toughened alumina (ZTA) ceramic femoral heads articulating against carbon fiber reinforced poly-ether-ether-ketone (CFR PEEK) acetabular cups with different diameters and clearances. Friction hip simulator was used to measure frictional torque and then friction factors were calculated along with Sommerfeld numbers leading to Stribeck analysis and hence the lubricating mode was also investigated. This involved using lubricants based on pure bovine serum (BS) and diluted bovine serum (25 vol. %BS+75 vol. %distilled water) with and without carboxymethyl cellulose (CMC) (as gelling agent). Standard Rheometer was used to measure lubricant viscosity ranged from 0.0014 to 0.236 Pas at a shear rate of 3000 . Pure bovine serum, diluted bovine serum without CMC and with CMC (25BS+75DW+0.5gCMC and +1gCMC) showed pseudoplastic flow behaviour up to shear rate of ~139 s⁻¹ above which a Newtonian flow with significant increase in shear stress was observed. The viscosity flow curves for the 25BS+75DW+2gCMC, +3.5gCMC and +5gCMC showed only shear thinning up to a shear rate of 3000 . The shear rate application modified the flow behaviour of bovine serum from a pseudoplastic to a Newtonian flow depending on its purity and CMC content. This will cause a different frictional behaviour depending on joint diameter and clearance, as seen in this work. The experimental data were compared with theoretical iv predictions of the lubricating regimes by calculating theoretical film thickness and lambda ratio. The metal-on-metal Biomet ReCaps showed similar trends of Stribeck curves, i.e. friction factors decreased from ~0.12 to ~0.05 as Sommerfeld numbers increased in the range of viscosities ~0.001-0.04Pas indicating mixed lubrication regimes above which the friction factor increased to ~0.13 at a viscosity of 0.236Pas. The Stribeck analyses suggested mixed lubrication as the dominant mode with the lowest friction factor in the range ~0.09 - ~0.05 at the physiological viscosities of ~0.01 to ~0.04 Pas and that such joints can be used for more active patients as compared to the conventional total hip replacement joints with 28mm diameter. The Stribeck curves for all ZTA ceramic-on-CFR PEEK components illustrated a similar trend with BS fluids showing higher friction factors (in the range 0.22-0.13) than the diluted BS+CMC fluids (in the range 0.24-0.05). The friction tests revealed boundary-mixed lubrication regimes for the ZTA ceramic-on-CFR-PEEK joints. The results, so far, are promising and suggest clearly that the newly developed ZTA ceramic femoral heads articulating against CFR PEEK cups have similar friction and lubrication behaviour at optimum clearances to those of currently used metal-onmetal hip resurfacing implants at the range of viscosities 0.00612 to 0.155Pas. These results clearly suggest that the ZTA ceramic-on-CFR-PEEK joints showed low friction at the physiological viscosities of ~0.01Pas in the range ~0.1-0.05, suggesting that these novel joints may be used as an alternative material choice for the reduction of osteolysis. The result of this investigation has suggested that the optimum clearance for the 52mm diameter MOM Biomet ReCaps could be ~170μm. However, 48 and 54mm joints showed lower friction due to clearances to be >200μm. For the 52mm ZTA ceramic-on-CFR-PEEK joints the optimum clearance seems to be ≥ 630μm radial clearance. These results suggested that increased clearance bearings have the potential to generate low friction and hence no risk of micro- or even macro-motion for the ceramic-on-CFR-PEEK joints. This study found no correlation between theoretical predictions and experimental data for all metal-onmetal and ZTA ceramic-on-CFR PEEK bearings at the physiological viscosity (0.0127Pas). However, at lubricant viscosity of 0.00157Pas, the theoretical prediction of lubrication regime correlated well with the experimental data, both illustrating boundary lubrication. As expected, a decrease in viscosity resulted decrease in the film thickness.
14

Friction and lubrication behaviour of hip resurfacing metal-on-metal and ZTA ceramic on CFR peek implants with various diameters and clearances. Friction and lubrication behaviour of hip resurfacing Co-Cr-Mo and zirconia toughened alumina ceramic heads against carbon fibre reinforced poly-ether-ether-ketone cups with various diameters and clearances have been investigated using serum-based lubricants.

Ehmaida, Mutyaa M. January 2012 (has links)
Total hip joint prostheses made of CoCrMo heads versus ultra high molecular weight polyethylene (UHMWPE) cups have a limited lifetime, mainly due to the wear of the UHMWPE cups as a result of high friction between the articulating surfaces leading to osteolysis and implant loosening with revision surgery becoming inevitable in more active patients. Tribology plays an important role in developing the design, minimizing wear and reducing friction of hip joint prostheses in order to improve their long-term performance, with good lubricating properties. Metal-on-metal hip resurfacing prostheses have shown significantly lower wear rates compared with conventional metal-on-polyethylene implants and thus osteolysis is potentially reduced leading to increased lifetime of the prosthesis. Nevertheless, excessive wear of metal-on-metal joints leads to metal ion release, causing pseudo-tumours and osteolysis. An alternative approach to such bearings is the use of newly developed carbon fiber-reinforced poly-ether-ether-ketone (CFR PEEK) acetabular cups articulating against ceramic femoral heads due to their better wear resistance compared to UHMWPE. In this study, therefore, friction and lubrication properties of large diameter, as cast, Co-Cr-Mo metal-on-metal hip resurfacing implants with various diameters and clearances have been investigated and compared to those of the newly developed zirconia toughened alumina (ZTA) ceramic femoral heads articulating against carbon fiber reinforced poly-ether-ether-ketone (CFR PEEK) acetabular cups with different diameters and clearances. Friction hip simulator was used to measure frictional torque and then friction factors were calculated along with Sommerfeld numbers leading to Stribeck analysis and hence the lubricating mode was also investigated. This involved using lubricants based on pure bovine serum (BS) and diluted bovine serum (25 vol. %BS+75 vol. %distilled water) with and without carboxymethyl cellulose (CMC) (as gelling agent). Standard Rheometer was used to measure lubricant viscosity ranged from 0.0014 to 0.236 Pas at a shear rate of 3000 . Pure bovine serum, diluted bovine serum without CMC and with CMC (25BS+75DW+0.5gCMC and +1gCMC) showed pseudoplastic flow behaviour up to shear rate of ¿139 above which a Newtonian flow with significant increase in shear stress was observed. The viscosity flow curves for the 25BS+75DW+2gCMC, +3.5gCMC and +5gCMC showed only shear thinning up to a shear rate of 3000 . The shear rate application modified the flow behaviour of bovine serum from a pseudoplastic to a Newtonian flow depending on its purity and CMC content. This will cause a different frictional behaviour depending on joint diameter and clearance, as seen in this work. The experimental data were compared with theoretical iv predictions of the lubricating regimes by calculating theoretical film thickness and lambda ratio. The metal-on-metal Biomet ReCaps showed similar trends of Stribeck curves, i.e. friction factors decreased from ~0.12 to ~0.05 as Sommerfeld numbers increased in the range of viscosities ~0.001-0.04Pas indicating mixed lubrication regimes above which the friction factor increased to ~0.13 at a viscosity of 0.236Pas. The Stribeck analyses suggested mixed lubrication as the dominant mode with the lowest friction factor in the range ~0.09 - ~0.05 at the physiological viscosities of ~0.01 to ~0.04 Pas and that such joints can be used for more active patients as compared to the conventional total hip replacement joints with 28mm diameter. The Stribeck curves for all ZTA ceramic-on-CFR PEEK components illustrated a similar trend with BS fluids showing higher friction factors (in the range 0.22-0.13) than the diluted BS+CMC fluids (in the range 0.24-0.05). The friction tests revealed boundary-mixed lubrication regimes for the ZTA ceramic-on-CFR-PEEK joints. The results, so far, are promising and suggest clearly that the newly developed ZTA ceramic femoral heads articulating against CFR PEEK cups have similar friction and lubrication behaviour at optimum clearances to those of currently used metal-onmetal hip resurfacing implants at the range of viscosities 0.00612 to 0.155Pas. These results clearly suggest that the ZTA ceramic-on-CFR-PEEK joints showed low friction at the physiological viscosities of ~0.01Pas in the range ~0.1-0.05, suggesting that these novel joints may be used as an alternative material choice for the reduction of osteolysis. The result of this investigation has suggested that the optimum clearance for the 52mm diameter MOM Biomet ReCaps could be ~170¿m. However, 48 and 54mm joints showed lower friction due to clearances to be >200¿m. For the 52mm ZTA ceramic-on-CFR-PEEK joints the optimum clearance seems to be ¿ 630¿m radial clearance. These results suggested that increased clearance bearings have the potential to generate low friction and hence no risk of micro- or even macro-motion for the ceramic-on-CFR-PEEK joints. This study found no correlation between theoretical predictions and experimental data for all metal-onmetal and ZTA ceramic-on-CFR PEEK bearings at the physiological viscosity (0.0127Pas). However, at lubricant viscosity of 0.00157Pas, the theoretical prediction of lubrication regime correlated well with the experimental data, both illustrating boundary lubrication. As expected, a decrease in viscosity resulted decrease in the film thickness.
15

Friction and lubrication behaviour of metal-on-metal and ZTA ceramic-on-CFR PEEK hip prostheses. Friction and lubrication behaviour of metal-on-metal hip resurfacing and ZTA ceramic heads versus CFR PEEK cups wiith various diameters and clearances using serum-based lubricants with various viscosities.

Said, Assma Musbah January 2012 (has links)
The natural hip joint in healthy people has a very low friction with very little (or no) wear. It works as a dynamically loaded bearing and is subjected to about 1-2 million cycles of loading per year. The applied load is the body weight which is tripled when walking and even higher during other activities such as running and jumping. Unfortunately these joints are not always healthy due to various causes such as fractures or disease leading to severe pain which necessitates joint replacement. Currently, the orthopaedic industries are working towards developing an ideal artificial hip joint with low wear, low friction, good lubrication, better fixation/stability and biocompatibility. Many different designs and materials have been investigated with some promising new implants which can be used depending on patients¿ individual need (large or small joint), activity and age. In this work, two types of artificial hip joints were tested for friction and lubrication studies: Metal-on-Metal (MoM) Biomet hip resurfacing ReCaps with large diameters (>35-60 mm) and different diametral clearances (~ 60-350 µm), and Zirconia Toughened Alumina (ZTA) heads against carbon-fibre-reinforced poly-ether-ether ketone (CFR PEEK) cups with different diameters (>35-60 mm) and diametral clearances (60-1860 µm). Seven serum-based lubricants with different viscosities were used with and without carboxy methyl cellulose (CMC) additions as gelling agent to increase viscosity depending on the CMC content. The maximum load applied was 2000 N for the stance phase with a minimum load of 100 N for the swing phase. A Pro-Sim friction hip simulator was used to investigate the frictional torque generated between the articulating surfaces so as the friction factor can be calculated. Stribeck analysis was then employed to assess the mode of lubrication. For the metal-on-metal hip resurfacing joints, the friction factors were in the range 0.03-0.151 and those for the ZTA ceramic heads versus CFR PEEK cups were in the range 0.006-0.32. Stribeck analyses showed mainly mixed lubrication for both MoM and ZTA ceramic-on-CFR PEEK joints. The experimental results were in agreement with most of the theoretical calculations suggesting mixed lubricating regimes at low viscosities and moving on to fluid film lubrication at higher viscosities. Joints with larger-diameters, lower clearances and lower surface roughness exhibited a higher lambda ratio suggesting improved lubrication. Viscosity flow curves for the serum-based lubricants having viscosity ¿ 0.00524 Pas showed non-linear relationship between viscosity and shear rate indicating non-Newtonian flow with pseudoplastic or shear-thinning characteristic, i.e. viscosity decreased as shear rate increased up to shear rates of ~ 1000 s-1. However, at shear rates greater than 1000 s-1 Newtonian flow became dominant with almost constant viscosity, i.e. a linear relationship between shear stress and shear rate. On the other hand, viscosity flow curves for the lubricants with viscosity ¿ 0.0128 Pas showed non-Newtonian behaviour up to a shear rate of 3000 s-1 with shear-thinning characteristic. / Ministry of Higher Education, Libya
16

Design and performance of cold bent glass

Datsiou, Kyriaki Corinna January 2017 (has links)
The demand for flat glass is high and increasing significantly in the building industry as a direct result of architectural requirements for lightness, transparency and natural light. Current architectural trends require glass in curvilinear forms for smooth free-form façades. Two principal challenges arise from this: to cost-effectively produce the desired curvature and; to ensure its safe performance after exposure to ageing. The recent availability of high strength glass provides an opportunity to address the first challenge by developing cold bent glass. Cold bending involves the straining of relatively thin glass components, at ambient temperatures, and is a low energy and cost effective manner of creating curvilinear forms. However, cold bending is not yet widely established as a reliable method. The aim of this thesis is to develop the understanding of cold bent glass during the bending process and to evaluate its post-ageing performance. This thesis, firstly, investigates the mechanical response of monolithic glass plates during the cold bending process. The stability of cold bent glass is investigated experimentally by bending it in double curved anticlastic shapes. A parametric numerical analysis involves different boundary conditions, geometrical plate characteristics and bending parameters. The principal outcome is that a local instability, now termed cold bending distortion, occurs when certain displacement limits are exceeded and could degrade the optical quality of the glass. An evaluation procedure is also formulated to set limits and aid designers/manufacturers to predict the mechanical response and the optical quality of the glass. Cold bent glass is subjected to permanent bending stresses throughout its service life and therefore, its strength degradation after ageing needs to be quantified. Analytical, experimental and numerical investigations are undertaken in this thesis to identify the most effective method for estimating glass strength (evaluation of destructive tests, required number of specimens, statistical analysis methods and sub-critical crack growth). The limited availability of naturally aged toughened glass and the absence of a reliable ageing standard impede the evaluation of its aged performance. Therefore, a parametric experimental investigation of artificial ageing methods on glass is undertaken in this thesis. A procedure for the evaluation of the strength of aged glass is finally, formulated to allow the selection of artificial ageing parameters that correspond to a target level of erosion. The knowledge on artificial ageing and strength prediction acquired above is finally implemented on different types of glass to determine their strength after ageing and assess their safe use in cold bending / load bearing applications. The investigation showed that fully toughened glass has a superior performance to chemically toughened or annealed glass. Overall, the research presented in this thesis demonstrates that high quality cold bent toughened glass can be created when certain applied displacement limits are respected. These can be used as a safe, cost-effective and energy efficient replacement to the more conventional hot bent glass. However, cold bending / load bearing applications in which the stressed glass surface is exposed to ageing, require glass with a relatively high case depth such as fully toughened or bi-tempered glass.

Page generated in 0.0302 seconds