441 |
Ultrasonographic screening of asymptomatic thyroid cancer in Hong KongChineseYuen, Po-wing., 袁寶榮. January 2010 (has links)
published_or_final_version / Medicine / Master / Doctor of Medicine
|
442 |
Comparative analysis of refractive outcome using partial coherence interferometry and ultrasound biometry in phacoemulsification cataractsurgeryYip, Pui-pui, Terri., 葉佩珮. January 2005 (has links)
published_or_final_version / Medical Sciences / Master / Master of Medical Sciences
|
443 |
Doppler ultrasound is a useful investigatory tool in the field of obstetrics & gynaecology陳鳳儀, Chan, Fung-yee. January 1995 (has links)
published_or_final_version / Medicine / Master / Doctor of Medicine
|
444 |
Sonographic features of fetuses with homozygous [alpha]-thalassaemia-1during early pregnancy林勇行, Lam, Yung-hang. January 2001 (has links)
published_or_final_version / Medicine / Master / Doctor of Medicine
|
445 |
Ultrasonic non-destructive testing using digital pulse compression許文山, Hui, Man-shan. January 1981 (has links)
published_or_final_version / Electrical Engineering / Master / Master of Philosophy
|
446 |
Computer aided ultrasonic flaw detection and characterization曾偉明, Tsang, Wai-ming, Peter. January 1987 (has links)
published_or_final_version / Electrical Engineering / Doctoral / Doctor of Philosophy
|
447 |
Deconvolution of three-dimensional medical ultrasoundGomersall, William Henry January 2011 (has links)
No description available.
|
448 |
Μελέτη και κατασκευή διάταξης έλεγχου πιεζοηλεκτρικού κινητήρα (Ultrasonic) με χρήση λογισμικού LabVIEWΠολύδωρος, Παναγιώτης 13 February 2009 (has links)
Στην παρούσα εργασία θα κατασκευασθεί διάταξη ελέγχου για τον Πιεζοηλεκτρικό
κινητήρα οδεύοντος κύματος.
Αρχικά συγκεντρώθηκε όλη η απαραίτητη βιβλιογραφία αναφορικά με τους
Πιεζοηλεκτρικούς κινητήρες. Η αναζήτηση χωρίστηκε σε δύο μέρη. Αναζήτηση τρόπων
οδήγησης του κινητήρα και σε αναζήτηση μεθόδων ελέγχου αυτού.
Στη συνέχεια συγκεντρώθηκαν όλες οι διαθέσιμες διατάξεις για την οδήγηση του
κινητήρα που είχαμε στη διάθεση μας. Οι διατάξεις αυτές ήταν δύο. Η πρώτη ήταν η
εργοστασιακή διάταξη, η οποία περιλαμβανόταν στο πακέτο αγοράς του κινητήρα και η
δεύτερη η διάταξη που είχε κατασκευασθεί από το Χ. Πάτσιο στα πλαίσια της διπλωματικής
του εργασίας. Για την όσο το δυνατόν καλύτερη κατανόηση της λειτουργίας τους καθώς και
αναγνώριση των μειονεκτημάτων, ώστε να τα απαλείψουμε στη δική μας διάταξη,
συντελέστηκαν αρκετά πειράματα με αυτές.
Το επόμενο βήμα ήταν να αποφασίσουμε ποιo είδος μετατροπέα θα χρησιμοποιήσουμε.
Αποφασίστηκε να διατηρήσουμε το σκεπτικό που αναπτύσσεται στη διπλωματική εργασία
του Χ. Πάτσιου, μιας και πληρούσε τις προϋποθέσεις που θέσαμε και ήταν καινοτόμο. Η
κατασκευή της διάταξης οδήγησης έγινε με ολοκληρωμένα ισχύος, δηλαδή με ολοκληρωμένα
που περιλαμβάνουν διακοπτικά στοιχεία ισχύος. Τα στοιχεία αυτά χρησιμοποιήθηκαν για
πρώτη φορά στο Εργαστήριο Ηλεκτρομηχανικής Μετατροπής Ενέργειας και για το λόγο αυτό
ήμασταν ιδιαιτέρως επιφυλακτικοί. Τελικά κρίθηκαν αντάξια των προσδοκιών που είχαμε
θέσει.
Στο σημείο αυτό άρχισε το δεύτερο τμήμα της εργασίας αυτής, η κατασκευή
λογισμικού ελέγχου. Υλοποιήθηκαν τρεις μέθοδοι ελέγχου, on/off, PID και Ασαφής έλεγχος.
Αρχικά παρατίθεται το θεωρητικό υπόβαθρο των μεθόδων και στη συνέχεια η εφαρμογή τους
στο κινητήρα. Το λογισμικό αναπτύχθηκε σε περιβάλλον LabVIEW. / In this paper, a resonant converter has been studied and constructed, in order to drive an Ultrasonic motor. In advance, three different control schemes have been applied (OnOff, PID and fuzzy).
|
449 |
Sonic Pest RepellentsAflitto, Nicholas, DeGomez, Tom 10 1900 (has links)
4 pp. / Commercially available sonic pest devices for use in residential applications have not been shown to be effective in scientific studies. For this reason, use of these devices is not advised to treat common pest problems. Although some researchers are developing sonic techniques that illustrate promise for very specific pests, these technologies are yet to be commercially available. As our understanding increases of how pest species receive and process sound, more relevant sonic devices may be developed. The allure of sound as a treatment for pests will remain into the future—motivated by the fact that if they are successful they will be more environmentally friendly and safer for humans.
|
450 |
MESH-FREE MODELING OF ULTRASONIC FIELDS GENERATED BY TRANSDUCERS AND ACOUSTIC MICROSCOPESYanagita, Tamaki January 2009 (has links)
With the gain in momentum of the structural health monitoring field in the last two decades, the popularity of ultrasonic nondestructive testing (NDT) has grown. However, ultrasonic NDT requires an expert to perform the testing and can be time consuming and costly when measured wave patterns in testing become extremely complex. A computer simulation of these tests can be utilized as a guide during actual evaluations or as a tool to train technicians. Presented in this dissertation is the development of models which simulate such acoustic phenomena as may arise in NDT. These models were developed using the distributed point source method (DPSM) for its proven capability to represent ultrasonic fields.Four sets of boundary conditions that arise from different types of commonly used acoustic transducers are modeled, enabling the visualization of the ultrasonic fields produced by the transducers. The transducer models exhibit good agreement with existing analytical solutions.In addition, the effect of a small cavity located at or near the focal point of an acoustic microscope is discussed. For this application the DPSM technique is modified so that inversion of a large global matrix is avoided, significantly improving the computational efficiency. The model shows that, as the pressure goes to zero, the velocity increases at the location of a cavity. Simulations demonstrate that the microscope is able to sense changes in position of the cavity by variations in the measured ratio of reflected to incident acoustic force.The field generated by an interferometric acoustic microscope is also presented. Qualitative agreement between the DPSM model and the experimental results of fields generated in a homogeneous fluid are obtained for a three-element lens. In the presence of a solid interface, the pressure on the edges of a converging beam near the fluid-solid interface is greater for a three-element lens than for single-element lens. A multi-element lens is also shown to exhibit oscillations in the pressure slightly above the interface.
|
Page generated in 0.0527 seconds