• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Hidrodinâmica do escoamento do sangue em microvasos / Hydrodynamics of blood flowin microvessels

Carvalho, Jonas Antonio Albuquerque de 06 June 2008 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2008. / Submitted by Jaqueline Oliveira (jaqueoliveiram@gmail.com) on 2008-12-08T16:49:29Z No. of bitstreams: 1 DISSERTACAO_2008_JonasAntonioADeCarvalho.pdf: 1641502 bytes, checksum: f25ccedd9dda701791548fac5ad11381 (MD5) / Approved for entry into archive by Georgia Fernandes(georgia@bce.unb.br) on 2009-02-16T15:13:24Z (GMT) No. of bitstreams: 1 DISSERTACAO_2008_JonasAntonioADeCarvalho.pdf: 1641502 bytes, checksum: f25ccedd9dda701791548fac5ad11381 (MD5) / Made available in DSpace on 2009-02-16T15:13:24Z (GMT). No. of bitstreams: 1 DISSERTACAO_2008_JonasAntonioADeCarvalho.pdf: 1641502 bytes, checksum: f25ccedd9dda701791548fac5ad11381 (MD5) / Neste trabalho estuda-se o escoamento e a reologia de fluidos não-newtonianos com propriedades mecânicas semelhantes as do sangue. Os cálculos e as análises apresentados são direcionados ao entendimento do escoamento em microvasos. Em regime de microcirculação avalia-se as propriedades mecânicas predominantes a serem usadas em diferentes modelos constitutivos do sangue. Usaram-se desde modelos de fluidos generalizados até um modelo protótipo do sangue usando emulsões para descrever o comportamento do sangue em escoamento em microvasos. Com os resultados avaliamse a influência das propriedades do sangue como, por exemplo, a presença da camada de plasma livre de células , fração volumétrica de glóbulos vermelhos, da tensão crítica de escoamento na viscosidade intrínseca do sangue. É obtida a solução por similaridade da equação da distribuição de gotas em um escoamento cisalhante na presença de uma parede rígida. O referido cálculo é uma primeira investigação da distribuição de células e dos mecanismos físicos envolvidos na formação da camada de plasma livre de células no regime da microcirculação. Uma emulsão diluída de gotas de alta razão de viscosidade com o meio líquido é usada como protótipo do fluido sangue na microcirculação. Acredita-se que a camada de plasma, livre de células, é o resultado do balanço entre dois mecanismo de fluxo de células protótipos; um associado à migração de partículas devido a presença da parede e outro associado à difusão hidrodinâmica de células. Como principal resultado determina-se a distribuição de gotas no espaço em função do tempo, a formação dessa camada livre de células e a espessura da camada em função dos parâmetros físicos envolvidos. Na etapa experimental, investiga-se o escoamento de emulsões e soluções poliméricas em tubos com objetivo de determinar a viscosidade intrínseca. Um tanque de estagnação permite controlar a pressão de entrada do escoamento. Propõe-se uma metodologia para medida da viscosidade intrínseca de fluidos complexos, como o sangue, em cisalhamento parabólico. ____________________________________________________________________________________________ ABSTRACT / In this work, non-newtonian fluids with approximated blood behavior flow and rheology are investigated. Some scaling analysis and calculations results are presented with the intent to understand the blood flow in microvessels. The main mechanical properties in microcirculation regime are determined to be used with different constitutive models of the blood. Generalized non-newtonian fluids and an emulsion prototype of blood are the different constitutive models used to describe blood behavior. With the results, the cell-depleted layer, the red blood cells volume fraction, the yield stress, are examples of the investigated parameters. The similarity solution of the distribution differential equation of droplets is calculated in a shear flow with a rigid wall. This solution is a first approach to understand the cells distribution and the mechanisms that affect the cell-depleted layer formation in microcirculation. A dilute emulsion of drops with high viscosity ratio is the prototype of blood in microvessels. Here, the cell depleted layer is a balance result of two different flux mechanisms: the cell migration due the presence of a rigid wall and the hydrodynamic diffusion of cells. The main results is the volume fraction in function of time and space of drops prototypes of red blood cells, the thickness of cell-depleted layer calculation and associated development time. In tube flow experiments are investigated polymeric solutions and different emulsions with the objective to calculate its intrinsic viscosities. A stagnation reservoir tank is used to control the intake pressure of the tube flow. A procedure to measure the intrinsic viscosity of complex fluids is proposed.
2

Estudo do impacto da viscosidade intrínseca do pet reciclado pós-consumo em embalagens cosméticas

Castro, Paula Junqueira de 14 August 2015 (has links)
Made available in DSpace on 2016-03-15T19:36:55Z (GMT). No. of bitstreams: 1 Paula Junqueira de Castro.pdf: 2618815 bytes, checksum: 92b10379ab9b859ea52e163bf40779ee (MD5) Previous issue date: 2015-08-14 / The use of PET in cosmetics packaging is growing and the use of post-consumer recycled material is an alternative with the development of recycling process and also with all the discussions about the increase of environmental impact. The objective of this project is to evaluate the influence of post-consumer recycled PET in the mechanical properties and the aesthetics appearance in cosmetics packaging. The materials used was virgin PET with nominal value of intrinsic viscosity (IV) of 0,80 dL/g and two grades of post-consumer recycled PET with nominal value of IV of 0,68dL/g and 0,80dL/g. The main parameter used in the PET industry is the IV because it is directly related to the molar mass of the polymer and also to the quality of the material. The packages were manufactured by injection stretch blow molding process with different percentages of virgin PET and post-consumer recycled PET. The characterization was realized by visual analysis, spectroscopy to evaluate the variation of color and mechanical tests. The results were satisfactory for the mechanical tests, showing no major differences in results when compared to virgin PET. In aesthetics appearance, the color variation is noticeable, due to the thermal degradation of the material, but less noticeable in the packages with the post-consumer recycled PET with lower IV. / A utilização de embalagens de PET na indústria de cosméticos é ampla e crescente, a incorporação de material reciclado pós-consumo passa a ser uma alternativa com o avanço da tecnologia da reciclagem mecânica do PET e do aumento da discussão de impacto ambiental. O objetivo principal do trabalho é avaliar a influencia na estética e na resistência mecânica do PET reciclado pós-consumo em embalagens de cosméticos com diferentes composições e valores de viscosidade intrínseca (VI). Utilizou-se PET virgem com valor nominal de VI 0,80 dL/g, PET reciclado pós-consumo com valor nominal de VI de 0,68dL/g e 0,80dL/. A VI é a medida mais difundida na indústria do PET, um importante parâmetro de qualidade do material, relacionado diretamente com a massa molar do mesmo. As embalagens foram produzidas através do processo de injeção-sopro com diferentes porcentagens de PET virgem e PET reciclado pós-consumo. A caracterização foi realizada através de analise visual, espectroscopia para avaliação da variação da cor e ensaios mecânicos. Os resultados foram satisfatórios para os ensaios mecânicos, não apresentando diferenças significativas dos resultados quando comparado ao PET virgem. Na questão estética, a variação de cor é bastante perceptível, decorrente da degradação termo-oxidativa do material, porém menos aparente para o PET reciclado pós-consumo com menor valor de VI.

Page generated in 0.0765 seconds