• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

High Slew Rate High-efficiency Dc-dc Converter

Wang, Xiangcheng 01 January 2006 (has links)
Active transient voltage compensator (ATVC) has been proposed to improve VR transient response at high slew rate load, which engages in transient periods operating in MHZ to inject high slew rate current in step up load and recovers energy in step down load. Main VR operates in low switching frequency mainly providing DC current. Parallel ATVC has largely reduced conduction and switching losses. Parallel ATVC also reduces the number of VR bulk capacitors. Combined linear and adaptive nonlinear control has been proposed to reduce delay times in the actual controller, which injects one nonlinear signal in transient periods and simplifies the linear controller design. Switching mode current compensator with nonlinear control in secondary side is proposed to eliminate the effect of opotocoupler, which reduces response times and simplifies the linear controller design in isolated DC-DC converters. A novel control method has been carried out in two-stage isolated DC-DC converter to simplify the control scheme and improve the transient response, allowing for high duty cycle operation and large step-down voltage ratio with high efficiency. A balancing winding network composed of small power rating components is used to mitigate the double pole-zero effect in complementary-controlled isolated DC-DC converter, which simplifies the linear control design and improves the transient response without delay time. A parallel post regulator (PPR) is proposed for wide range input isolated DC-DC converter with secondary side control, which provides small part of output power and most of them are handled by unregulated rectifier with high efficiency. PPR is easy to achieve ZVS in primary side both in wide range input and full load range due to 0.5 duty cycle. PPR has reduced conduction loss and reduced voltage rating in the secondary side due to high turn ratio transformer, resulting in up to 8 percent efficiency improvement in the prototype compared to conventional methods.
2

Advanced voltage control for energy conservation in distribution networks

Gutierrez Lagos, Luis Daniel January 2018 (has links)
The increasing awareness on the effect of carbon emissions in our planet has led to several countries to adopt targets for their reduction. One way of contributing to this aim is to use and distribute electricity more efficiently. In this context, Conservation Voltage Reduction (CVR), a well-known technique that takes advantage of the positive correlation between voltage and demand to reduce energy consumption, is gaining renewed interest. This technique saves energy by only reducing customer voltages, without relying on customer actions and, therefore, can be controlled by the Distribution Network Operator (DNO). CVR not only brings benefits to the electricity system by reducing generation requirements (fewer fossil fuel burning and carbon emissions), but also to customers, as energy bill reductions. The extent to which CVR can bring benefits mainly depends on the customers load composition and their voltages. While the former dictates the voltage-demand correlation, the latter constraints the voltage reduction that can be applied without violating statutory limits. Although CVR has been studied for many years, most of the studies neglect the time-varying voltage-demand characteristic of loads and/or do not assess end customer voltages. While these simplifications could be used to estimate CVR benefits for fixed and limited voltage reductions, realistic load and network models are needed to assess the performance of active CVR schemes, where voltages are actively managed to be close to the minimum limit. Moreover, distribution networks have been traditionally designed with limited monitoring and controllability. Therefore, CVR has been typically implemented by adopting conservative voltage reductions from primary substations, for both American and European-style networks. However, as new infrastructure is deployed in European-style LV networks (focus of this work), such as monitoring and on-load tap changers (OLTCs), the opportunity arises to actively manage voltages closer to end customer (unlocking further energy savings). Although these technologies have shown to effectively control voltages in LV networks, their potential for CVR has not been assessed before. Additionally, most CVR studies were performed in a context where distributed generation (DG) was not common. However, this has changed in many countries, with residential photovoltaic (PV) systems becoming popular. As this is likely to continue, the interactions of residential PV and CVR need to be studied. This thesis contributes to address the aforementioned literature gaps by: (i) proposing a simulation framework to characterise the time-varying voltage-demand correlation of individual end customers; (ii) developing a process to model real distribution networks (MV and LV) from DNO data; (iii) adopting a Monte Carlo-based quantification process to cater for the uncertainties related to individual customer demand; (iv) assessing the CVR benefits that can be unlocked with new LV infrastructure and different PV conditions. To accomplish (iv), first, a simple yet effective rule-based scheme is proposed to actively control voltages in OLTC-enabled LV networks without PV and using limited monitoring. It is demonstrated that by controlling voltages closer to customers, annual energy savings can increase significantly, compared to primary substation voltage reductions. Also, to understand the effect of PV on CVR, a centralized, three-phase AC OPF-based CVR scheme is proposed. This control, using monitoring, OLTCs and capacitors across MV and LV networks, actively manages voltages to minimize energy consumption in high PV penetration scenarios whilst considering MV-LV constraints. Results demonstrate that without CVR, PV systems lead to higher energy imports for customers without PV, due to higher voltages. Conversely, the OPF-based CVR scheme can effectively manage voltages throughout the day, minimising energy imports for all customers. Moreover, if OLTCs at secondary substations are available (and managed in coordination with the primary substation OLTC), these tend to regulate customer voltages close to the minimum statutory limit (lower tap positions), while the primary OLTC delivers higher voltages to the MV network to also reduce MV energy losses.

Page generated in 0.0694 seconds