• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The Effect of Cone Beam CT Voxel Size on the Identification of Vertical and Horizontal Root Fractures: An In-vitro Study

Amintavakoli, Niloufar 20 November 2013 (has links)
Objective: The purpose of this study is to determine the relationship between cone beam CT (CBCT) voxel size and tooth root fracture detection. Materials and Methods: Vertical and horizontal root fractures were induced in a total of 30 teeth, and 15 teeth were left intact. Teeth were imaged with projection digital radiography and the Kodak 9000 3D CBCT system with a native voxel size of 76 μm. The CBCT voxels were then downsampled to 100 μm, 200 μm and 300 μm. Five blinded observers evaluated both sets of images with a 1 week washout interval between each set of observations. Results: CBCT outperformed the projection images for fracture detection for all voxel sizes except 300 μm (p<0.05). No significant differences were found between the different voxel sizes (p>0.05). Conclusion: Although voxel size does not impact the interpretation of root fractures, in vitro, CBCT outperformed projection imaging for voxel sizes less than 300 μm.
2

The Effect of Cone Beam CT Voxel Size on the Identification of Vertical and Horizontal Root Fractures: An In-vitro Study

Amintavakoli, Niloufar 20 November 2013 (has links)
Objective: The purpose of this study is to determine the relationship between cone beam CT (CBCT) voxel size and tooth root fracture detection. Materials and Methods: Vertical and horizontal root fractures were induced in a total of 30 teeth, and 15 teeth were left intact. Teeth were imaged with projection digital radiography and the Kodak 9000 3D CBCT system with a native voxel size of 76 μm. The CBCT voxels were then downsampled to 100 μm, 200 μm and 300 μm. Five blinded observers evaluated both sets of images with a 1 week washout interval between each set of observations. Results: CBCT outperformed the projection images for fracture detection for all voxel sizes except 300 μm (p<0.05). No significant differences were found between the different voxel sizes (p>0.05). Conclusion: Although voxel size does not impact the interpretation of root fractures, in vitro, CBCT outperformed projection imaging for voxel sizes less than 300 μm.
3

Can Application of Artifact Reduction Algorithm or Increasing Scan Resolution Improve CBCT Diagnostic Accuracy of TAD - Tooth Root Contact?

McLaughlin, Victoria L. 01 October 2021 (has links)
No description available.

Page generated in 0.0287 seconds