Spelling suggestions: "subject:"waterproof""
1 |
A study of permeability control with asphalt emulsionsDrumm, Don A January 2011 (has links)
Digitized by Kansas Correctional Industries
|
2 |
The stability to laundering of durable water repellentsNacht, Alan David 12 1900 (has links)
No description available.
|
3 |
Assessment of Water Penetration Resistance of Coatings on Wood by Droplet Dynamics AnalysisBaptista, Diogo January 2005 (has links) (PDF)
No description available.
|
4 |
The structure-property relationships of urethane-acrylic thermosetting systemsLau, Soo-Khim January 1995 (has links)
Urethane-acrylic copolymers have found increasing use as a radiation curable materials in the recent years. These copolymers are highly crosslinked through the use of acrylic monomers having more than one double bond. Stirling Lloyd had discovered such materials to be a successful alternative to the urethane or acrylics coatings as waterproof membrane coatings. In this project, structure-property relationships of UA copolymer systems were studied. These were peroxide cured at room temperature.
|
5 |
Ověření těsnících vlastností membránových hmot z hlediska šíření vlhkosti v podzemním stavitelství / Verification of sealing properties of membrane materials in terms of moisture propagation in underground constructionČanigová, Veronika January 2019 (has links)
This diploma thesis is aimed at verifying the properties of joints of waterproofing membranes generaly used in underground constructions and also deals with the possible addition of a swelling profile as a barrier to permeating water through the defect in the waterproofing system. The most commonly used materials for waterproofing membranes are polymers. The work is focused on verifying the properties of automatic and manual welding joints of polyvinylchloride membrane. In actual practice, there is a pressure test being used for automatic weldings, and for manual weldings there are tests with a tear-off needle and a vacuum bell. In the laboratory, it is also possible to verify the joints using a peeling test and determining the shear strength of the joint using a testing device. In case of damaged waterproofing system and soaking of pressurized water, it is possible to use a swellable strip as a barrier for the water leaking from one injection compartment to another. At the end of the thesis there is a comparison of the waterproofing system without the swelling profile and the system including its application. The swelling profile has shown very good properties with regard to the infiltration of the flowing water into its structure, and so the amount of water that could be applied to the sample with the swelling profile was much higher than in the case of the generaly used waterproofing system.
|
6 |
ESTUDO DOS SISTEMAS DE IMPERMEABILIZAÇÃO: PATOLOGIAS, PREVENÇÕES E CORREÇÕES ANÁLISE DE CASOS. / STUDY OF WATERPROOFING SYSTEMS: PATHOLOGIES, PREVENTIONS AND CORRECTIONS CASE STUDIES.Righi, Geovane Venturini 18 December 2009 (has links)
The waterproofing is a very important step in the civil construction, but it has been relegated, mostly by cost containment and misinformation, resulting in the
manifestation of waterproofing pathologies. Repair costs of these pathologies can be up to fifteen times higher than if it were running on the course of the work. This study presents a multiple cases studies of waterproofing pathologies, with suggestions of corrections and indications on how to prevent such pathologies. To better illustrate the subject, it was accomplished an inspection of the main types of materials used in the waterproofing process, as well as the applied techniques, main cares that should be considered in the execution and indispensable constructive details in the process. / A impermeabilização é uma etapa muito importante na construção civil, mas vem sendo relegada, na maioria das vezes por contenção de custos e desinformação, resultando no aparecimento de patologias de impermeabilização. Os
custos do reparo dessas patologias podem ser até quinze vezes maiores do que se fosse executado no andamento da obra. Esse estudo apresenta uma análise de múltiplos casos de patologias de impermeabilização, com sugestões de correções e indicações de como prevenir tais patologias. De forma a elucidar melhor sobre o assunto, primeiro foi realizado um levantamento dos principais tipos de materiais usados no processo de impermeabilização, assim como técnicas de uso, principais cuidados que se deve ter na execução e detalhes construtivos indispensáveis no processo.
|
7 |
Asphalt-Crumb Rubber Waterproofing MembraneFrobel, Ronald K., Jimenez, R. A., Cluff, C. Brent, Morris, Gene R. 19 March 2014 (has links)
No date on item. Authors' manuscript. / This report is concerned with laboratory testing and field investigations of a water seepage barrier consisting of asphalt cement and
reclaimed crumb-rubber tire peel. The test methods that were utilized and evaluated included the following: water vapor transmission (ASTM E96 -72, Procedure BW), water absorption (ASTM 570-72), ductility (ASTM D113-74), viscosity, toughness, and brittleness /impact resistance (ASTM 0994-72). The test results showed that the asphalt-rubber as a membrane is relatively impermeable and absorbs an insignificant amount of water. The crumb rubber effectively increases the viscosity of the asphalt cement while decreasing the ductility value. The asphalt-rubber combination exhibits a tough, impact resistant membrane with excellent waterproofing properties.
|
8 |
Concreto permeável para pavimentação urbana com uso de resíduos de construção e demolição produzidos na usina de reciclagem de são josé do Rio PretoAlves, Priscila Borges [UNESP] 13 November 2015 (has links) (PDF)
Made available in DSpace on 2016-05-17T16:51:49Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-11-13. Added 1 bitstream(s) on 2016-05-17T16:55:44Z : No. of bitstreams: 1
000864135.pdf: 2829972 bytes, checksum: 76ff595e8a34bbcadd273fe1e6da5181 (MD5) / No presente trabalho foram utilizados resíduos de construção e demolição oriundos de uma central de reciclagem, visando a confecção de concretos permeáveis. Objetivou-se avaliar a influência da utilização destes resíduos no comportamento mecânico do concreto permeável, tendo em vista a sua utilização na pavimentação de espaços urbanos, com enfoque na permeabilidade do pavimento. O trabalho consistiu de pesquisa experimental, com realização das seguintes etapas: caracterização dos materiais utilizados, segundo as normas específicas; realização de ensaios para determinação do traço adequado do concreto; realização de ensaios de permeabilidade com o uso de um permeâmetro de carga variável; realização de ensaios para determinação do coeficiente de porosidade e realização de ensaios de resistência à compressão. Foram moldados quatro modelos, sendo um de referência e os demais com 5%, 10% e 15% de substituição de brita por RCD e os ensaios foram feitos nas idades de 7, 28 e 56 dias. O concreto permeável produzido com os resíduos de construção apresentaram resultados satisfatórios, em termos de drenagem e resistência, alcançando parâmetros adequados para este tipo de concreto / In this paper we used construction and demolition waste originating from a central recycling, aiming to elaborate permeable concrete. The objective was to evaluate the influence of the use of these wastes in the mechanical behavior of permeable concrete, with a view to their use in paving urban spaces, focusing on the permeability of the pavement. The work consisted of experimental research, performed the following steps: characterization of the materials used according to specific rules; performing tests to determine the appropriate dash of concrete; performing permeability test using a variable load permeameter; performing tests to determine the coefficient of porosity and performing compressive strength tests. Four models were molded, being a reference and the other with 5%, 10% and 15% of gravel replacement for RCD and the tests were made at the ages of 7, 28 and 56 days. The permeable concrete produced with the construction waste showed satisfactory results, in terms of drainage and compressive strength, achieving appropriate parameters for this type of concrete
|
9 |
Sistema de proteção superficial de estruturas de concreto de usinas hidrelétricas para controle da reação álcali-agregadoAlbertini, Paloma Gazolla de Oliveira [UNESP] 16 June 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:57Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-06-16Bitstream added on 2014-12-02T11:20:49Z : No. of bitstreams: 1
000797239.pdf: 4468238 bytes, checksum: ceb6e8ff08c946d0fe6c81146a6cc16c (MD5) / A reação álcali-agregado é um fenômeno expansivo que afeta a durabilidade e a segurança de estruturas de concreto e sabe-se que a mesma está intimamente ligada à presença de umidade. Apesar da grande quantidade de pesquisas voltadas ao tema, ainda não foram esclarecidas maneiras de como interromper a reação e impedir os progressos das expansões. Porém, pesquisas recentes indicam o uso de produtos impermeabilizantes como ferramenta na diminuição da umidade disponível no interior do concreto e consequentemente, na mitigação da reação após seu início. Então, visando diminuir a umidade interna em estruturas de concreto, o projeto aqui apresentado tem como objetivo avaliar a utilização de impermeabilizantes, quantificando a eficiência desses produtos testados através de sensores de umidade e de temperatura, embutidos no concreto em fase posterior à sua execução e também avaliar a utilização destes produtos na prevenção de expansões no concreto devido à RAA. Além da parte experimental, este trabalho traz um levantamento do estado da arte da Usina Hidrelétrica Jaguari mostrando resultados de trabalhos desenvolvidos anteriormente e com a apresentação de dados atualizados, divulgando uma recente taxa de expansão da estrutura da Tomada d´Água da Usina / The alkali-aggregate reaction is an expanding problem that affects the durability and safety of concrete structures and it is linked to the presence of moisture in concrete but are not yet clear ways of how to stop the reaction and prevent the progress of the expansions. Recent research indicates the use of waterproofing products as a tool in the reduction of available moisture within the concrete and thereby mitigate the reaction after its inception. So in order to reduce indoor moisture in concrete structures, this project aims to evaluate the use of waterproofing products, quantifying the efficiency of the products tested by sensors embedded in concrete and also in preventing expansions in the concrete due to AAR. Besides the experimental part, this work provides a survey of the State of the Art of Jaguari Hydroelectric Power Plant showing results of previous work and the presentation of updated data developed, disseminating a recent rate of expansion of the structure of Jaguari water intake structure
|
10 |
Sistema de proteção superficial de estruturas de concreto de usinas hidrelétricas para controle da reação álcali-agregado /Albertini, Paloma Gazolla de Oliveira. January 2014 (has links)
Orientador: Antonio Anderson da Silva Segantini / Banca: Selmo Chapira Kuperman / Banca: Rogério de Oliveira Rodrigues / Resumo: A reação álcali-agregado é um fenômeno expansivo que afeta a durabilidade e a segurança de estruturas de concreto e sabe-se que a mesma está intimamente ligada à presença de umidade. Apesar da grande quantidade de pesquisas voltadas ao tema, ainda não foram esclarecidas maneiras de como interromper a reação e impedir os progressos das expansões. Porém, pesquisas recentes indicam o uso de produtos impermeabilizantes como ferramenta na diminuição da umidade disponível no interior do concreto e consequentemente, na mitigação da reação após seu início. Então, visando diminuir a umidade interna em estruturas de concreto, o projeto aqui apresentado tem como objetivo avaliar a utilização de impermeabilizantes, quantificando a eficiência desses produtos testados através de sensores de umidade e de temperatura, embutidos no concreto em fase posterior à sua execução e também avaliar a utilização destes produtos na prevenção de expansões no concreto devido à RAA. Além da parte experimental, este trabalho traz um levantamento do estado da arte da Usina Hidrelétrica Jaguari mostrando resultados de trabalhos desenvolvidos anteriormente e com a apresentação de dados atualizados, divulgando uma recente taxa de expansão da estrutura da Tomada d'Água da Usina / Abstract: The alkali-aggregate reaction is an expanding problem that affects the durability and safety of concrete structures and it is linked to the presence of moisture in concrete but are not yet clear ways of how to stop the reaction and prevent the progress of the expansions. Recent research indicates the use of waterproofing products as a tool in the reduction of available moisture within the concrete and thereby mitigate the reaction after its inception. So in order to reduce indoor moisture in concrete structures, this project aims to evaluate the use of waterproofing products, quantifying the efficiency of the products tested by sensors embedded in concrete and also in preventing expansions in the concrete due to AAR. Besides the experimental part, this work provides a survey of the State of the Art of Jaguari Hydroelectric Power Plant showing results of previous work and the presentation of updated data developed, disseminating a recent rate of expansion of the structure of Jaguari water intake structure / Mestre
|
Page generated in 0.0731 seconds