• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • 1
  • Tagged with
  • 6
  • 6
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

せん断力を受ける無補剛箱形断面部材の強度と変形能

葛西, 昭, KASAI, Akira, 渡辺, 智彦, WATANABE, Tomohiko, 宇佐美, 勉, USAMI, Tsutomu, CHUSILP, Praween 04 1900 (has links)
No description available.
2

Lateral Torsional Buckling Strength of Sinusoidal Corrugated Web Plate Girders

Reinders, Philip January 2022 (has links)
Corrugated web plate girders (CWPGs) have become an increasingly popular structural member in Canada in recent years. This is because of their economic efficiency over standard wide flange members. Although the flexural performance of such has been increasingly studied in recent years there is still advancements that can be made in their design. No research has been completed in Canada on the subject of lateral torsional buckling (LTB) strength and very minimal research has been published on sinusoidal CWPGs. In order to examine the LTB strength of a CWPG with a sinusoidally shaped web, nine specimens were loaded and failed in simply supported arrangement that favours lateral torsional buckling. Specimens were chosen to observe the difference in strength due to web thickness, web depth and variation in identical beams. All of the specimens recorded strengths that exceeded the theoretical design strengths confirming that the current design procedure is conservative. A trend of ultimate capacity increasing was observed with the increase of web thickness. The depth of the web had no significant effect on the torsional strength besides what is gained from the increased flange distance. An equivalent web thickness equation was formulated based on the results for the purpose of calculating LTB strength. To test the proposed equation a numerical analysis was run on a wider range of beams and compared with the testing results. It was determined the physical testing results can be effectively captured by the proposed equation among more than just the tested beams. Two additional analyses were prepared to lay the foundation for further investigation of the proposed equation. The first was a Monte Carlo simulation to test the risk of using the proposed equation which requires additional data. Secondly, a preliminary finite element analysis (FEA) model was developed and presented for future use to expand this research. / Thesis / Master of Applied Science (MASc) / Corrugated web plate girders (CWPG) have grown in popularity due to their economic efficiency. No research has been presented in Canada and very minimal research has been published on the lateral torsional strength of CWPGs with sinusoidally corrugated webs. This research studied the lateral torsional buckling (LTB) strength of CWPGs through the experimental testing of physical members and a new equation for the calculation of the LTB strength is proposed. This equation and design process was then numerically tested to determine its viability as a design process.
3

A State of the Art Review of Special Plate Shear Walls

Just, Paul J., III 28 June 2016 (has links)
No description available.
4

Detailed Fem Analysis Of Two Different Splice Steel Connections

Yilmaz, Oguz 01 September 2008 (has links) (PDF)
Beam splices are typically located at moment contraflexure points (where M=0). Most design specifications require these splices to develop a strength either to meet design forces or a minimum value set by specifications. The design forces are typically determined through elastic analysis, which does not include flexibility of splice connections. In this research, two types of splice connections, an extended end plate splice connection and a flange and web plate bolted splice connection, were tested and analyzed to investigate the effect of the partial strength splice connections on structural response. The splices were designed to resist 40% and 34% of connecting section capacities using current steel design codes, respectively. It has been observed from the experiments and FEM analysis results that splice connections designed under capacities of connecting steel members can result in changes in design moment diagrams obtained from analyses without splice connection simulation and can also significantly decrease the rigidity of the structure endangering serviceability. The differences in design moment diagrams can go up to 50 % of elastic analysis without connection flexibility. The vertical displacements can increase to 155% of values obtained from elastic analysis with no splice connection simulation. Therefore, connection flexibility becomes very important to define in analysis.
5

Železniční most přes místní silnici / Railway Bridge across Local Road

Olbert, Jan January 2016 (has links)
The thesis deals with the variant design of the steel structure of single-track railway bridge on the line Tišnov – Nové Město na Moravě. The task is bridging the local road by a bridge structure with one field. Length of the bridge is 40 m.
6

Nosná ocelová konstrukce prodejny a opravny automobilů / Steel Load-bearing Structure of a Car Showroom and Repair Centre

Thomanková, Lucie January 2012 (has links)
Diploma thesis includes design and examination of steel load-carrying structure. Construction includes car deal warehouse and car repair shop with extension for car varnishing. Car deal warehouse has ground dimensions 22 x 30 m and total high 10 m. Main frame is composed of Vierendeel trusses with arc shape. Car repair shop has ground dimensions 20 x 30 m and total high 10 m. Main frame is composed of truss girders and web-plate columns. Frame extension has ground dimension 20 x 10 m and total high 6,4 m. Cladding is composed of sandwich panels. Store´s gable wall and a part of the roof are glass. Climatic load is intended for locality Ostrava.

Page generated in 0.0381 seconds