• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 3
  • 1
  • Tagged with
  • 109
  • 109
  • 39
  • 31
  • 30
  • 28
  • 28
  • 25
  • 18
  • 18
  • 16
  • 15
  • 15
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Incorporação de radionuclídeos em nanotubos naturais ativados / Radionuclides incorporation in activated natural nanotubes

SILVA, JOSÉ P. 26 August 2016 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2016-08-26T13:45:52Z No. of bitstreams: 0 / Made available in DSpace on 2016-08-26T13:45:52Z (GMT). No. of bitstreams: 0 / Os nanotubos naturais da paligorsquita, por apresentarem propriedades físicas e químicas específicas, têm potencial uso como nano sorventes e matrizes para imobilização, retenção, e solidificação de radionuclídeos presentes em efluentes nucleares. No processo de desenvolvimento de materiais com propriedades de sorção visando a incorporação e imobilização de radionuclídeos, as etapas mais importantes são a geração de sítios ativos simultaneamente com o aumento da área superficial específica e tratamento térmico adequado para conduzir ao colapso estrutural. Neste estudo foram avaliados parâmetros e condições determinantes no processo de ativação dos nanotubos naturais da paligorsquita visando a sorção de radionuclídeos de interesse na estrutura dos nanotubos e a avaliação posterior dos parâmetros que afeitam ao colapso estrutural por tratamento térmico. Por este estudo constatou-se que a otimização do processo de ativação ácida é fundamental para o aumento da capacidade de sorção de níquel usando estruturas de nanotubos naturais ativados. A condição otimizada de ativação superficial, mantendo a integridade estrutural foi removido cerca de 33,3% dos cátions de magnésio, equivalente a 6,30·10-4 mol·g-1 de magnésio em massa, aumentando a área superficial específica em 42,8%. Este aspecto permitiu a incorporação de mesma concentração molar de níquel presente nos rejeitos radioativos líquidos em um tempo de processo de 80min. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
102

Ação da radiação de alta energia nas propriedades mecânicas de compostos elastoméricos a base de SBR carregados com barita

Almeida, Jademir Jesus Pirapora de 30 March 2012 (has links)
Made available in DSpace on 2016-03-15T19:36:37Z (GMT). No. of bitstreams: 1 Jademir Jesus Pirapora de Almeida.pdf: 6328511 bytes, checksum: a6b516ba7f4098781189faf6cc895d92 (MD5) Previous issue date: 2012-03-30 / Universidade Presbiteriana Mackenzie / In this work were studied the action of ionizing radiation on the physical-mechanical properties in elastomeric compounds based on styrene-butadiene rubber (SBR) filled with barite, opening way for application of these composites in the protection and shield against high-energy radiation, in the form of aprons. These aprons come to substitute the elastomeric ones with lead filler in ergonomic and economically advantageous conditions. The effect of high-energy radiation was studied on SBR compounds filled with barite at 50, 75, 100, 125, and 150phr (phr = parts per hundred rubber) of barite concentrations, exposed to ionizing radiation at 0, 100, 200, 500 and 1000kGy doses. The samples were characterized by physic-mechanical tests as rheometry, tensile strength, resilience, hardness, wear resistance, oil absorption, permanent deformation under compression (compression set) and dynamic mechanical thermal analysis. The morphological characteristics were determined by scanning electron microscopy. The results showed that the radiation causes an increase in tensile strength and elongation, the tear strength and hardness, and a decrease in fluid absorção and deformation under compression. / Neste trabalho foi estudada a ação da radiação ionizante nas propriedades físico-mecânicas nos compostos elastoméricos a base de estireno-butadieno (SBR) carregados com barita, abrindo caminho para aplicação destes compostos na proteção e blindagem contra a radiação alta energia, na forma de aventais, vindo substituir os aventais a base de elastômero carregado com chumbo em condições ergonômicas e economicamente vantajosas. Foi estudado o efeito da radiação ionizante em compostos a base de SBR carregado com barita nas concentrações de 50, 75, 100, 125, e 150phr (phr = partes por cem de borracha) de barita expostos à radiação ionizante nas doses de 0, 100, 200, 500 e 1000kGy. As amostras foram caracterizadas por meio de ensaios físico-mecânicos de reometria, de resistência à tração, resiliência, dureza, resistência ao rasgo, absorção de óleo, deformação permanente sob compressão (compression set) e ensaios de análise térmica dinâmico-mecânica. As características morfológicas dos compositos foram determinadas por meio de microscopia eletrônica de varredura. Os resultados mostraram que a radiação provoca um aumento da resistência à tração, do alongamento sob tração, da resistência ao rasgamento e da dureza; e um decréscimo na absorção de fluido e na deformação sob compressão.
103

Úloha nádorového supresoru PML v odpovědi na poškození DNA a buněčné senescenci po genotoxickém stresu / Role of the tumour suppressor PML in DNA damage response and cellular senescence after genotoxic stress

Knoblochová, Lucie January 2015 (has links)
The promyelocytic leukemia protein (PML) is a tumour suppressor. It has been reported that PML interaction with the p53 protein is involved in the activation of cell cycle checkpoints and, when persistent, may lead to the premature onset of cellular senescence. Cellular senescence is a state of permanent cell growth arrest that is associated with characteristic morphological and metabolic changes and persistent DNA damage signalling. Importantly, PML nuclear bodies coassociate with persistent DNA damage foci in senescent cells; however, the role of this interaction is still obscure. My goal was to characterize the role of PML in DNA damage response (DDR) and the induction of premature cellular senescence after genotoxic stress, namely X-radiation, using both siRNA-mediated PML knock down (PML KD) and complete PML knock out (PML KO) in human cells. The dynamics of DNA damage foci, levels of various proteins involved in DDR, and proliferation rate were measured in both PML KD and KO cells. No significant changes in the formation of DNA damage foci, activated DDR (p53 and Chk2), activated p21CIP1/WAF1 cyclin-dependent kinase inhibitor, senescent morphology, and SA-β-galactosidase activity in PML KO cells were observed. However, PML KO cells displayed higher levels of retinoblastoma protein (Rb) and...
104

Estudo do efeito da radiacao gama sobre a molecula de tetraciclina relativamente ao seu comportamento como agente complexante e extrator

ANDRADE e SILVA, LEONARDO G. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:30:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:26Z (GMT). No. of bitstreams: 1 01387.pdf: 2053886 bytes, checksum: 9c61b3e10e5af0bb9a9a9cb8707260c7 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
105

Estudo comparativo de nanocompósitos de polipropileno modificado sob condições de envelhecimento ambiental e acelerado / Comparative study of modified polypropylene nanocomposites under environment and accelerated ageing conditions

KOMATSU, LUIZ G.H. 22 June 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T12:34:18Z No. of bitstreams: 0 / Made available in DSpace on 2016-06-22T12:34:18Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
106

Estudo do efeito da radiacao gama sobre a molecula de tetraciclina relativamente ao seu comportamento como agente complexante e extrator

ANDRADE e SILVA, LEONARDO G. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:30:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:26Z (GMT). No. of bitstreams: 1 01387.pdf: 2053886 bytes, checksum: 9c61b3e10e5af0bb9a9a9cb8707260c7 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
107

Estudo comparativo de nanocompósitos de polipropileno modificado sob condições de envelhecimento ambiental e acelerado / Comparative study of modified polypropylene nanocomposites under environment and accelerated ageing conditions

KOMATSU, LUIZ G.H. 22 June 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T12:34:18Z No. of bitstreams: 0 / Made available in DSpace on 2016-06-22T12:34:18Z (GMT). No. of bitstreams: 0 / O entendimento dos mecanismos de degradação que agem sob os nanocompósitos poliméricos frente ao intemperismo (luz UV, calor, oxigênio, chuva ácida, entre outros), é o ponto chave para o desenvolvimento de novos aditivos e novas aplicações. Para este trabalho a síntese do nanocompósito foi realizada no estado fundido, utilizando-se uma extrusora de dupla rosca. A matriz polimérica utilizada foi o HMS-PP (polipropileno com alta resistência do fundido) sintetizado por irradiação gama e a argila Montmorilonita. Para melhor compatibilização entre a matriz e a nanocarga, foi utilizada o agente compatibilizante andrido maléico. Para os ensaios de envelhecimento ambiental e acelerado em estufa, os corpos de prova foram confeccionados por meio de termoprensagem. A caracterização dos efeitos da adição de argila e do envelhecimento nos nanocompósitos, presupôs o emprego das técnicas de ensaios mecânicos, Calorimetria Diferencial Exploratória (DSC), Termogravimetria (TGA), Espectroscopia no Infravermelho por Transformada de Fourier (FT-IR), Espectrometria de Fluorescêcia de Raios X por Dispersão de Comprimento de Onda (WDXRF), Microscopia Eletrônica de Varredura (MEV), Índice de Fluidez (IF), Difração de Raios-X (DRX) e Espectroscopia de Energia Dispersiva (EDS). Foram ensaiadas amostras com 0,1; 1; 3; 5 e 10% de argila. A amostra com porcentagem de 5% de argila demonstrou uma melhor estabilidade frente ao ensaio de envelhecimento ambiental e no envelhecimento acelerado em estufa. Por outro lado na amostra com maior porcentagem de argila (10%) ocorreu o inverso, sob ensaio ambiental houve maior degradação e sob envelhecimento acelerado em estufa, manteve-se resistente até 56 dias de envelhecimento. Nas porcentagens estudas (menor que ≤ 3%) de argila, pode-se constatar um equilíbrio entre o efeito barreira da argila e a ação dos íons metálicos que aceleram o processo degradativo. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
108

Desenvolvimento e aplicação de um simulador pediátrico craniano para dosimetria em tomografia computadorizada / Development and application of a pediatric head phantom for dosimetry in computed tomography

MARTINS, ELAINE W. 26 August 2016 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2016-08-26T10:42:03Z No. of bitstreams: 0 / Made available in DSpace on 2016-08-26T10:42:03Z (GMT). No. of bitstreams: 0 / Para avaliar os níveis de exposição e a dose absorvida em pacientes submetidos a exames de tomografia computadorizada, TC, é necessário calcular os índices de dose em medições com um simulador de PMMA, ou cheio de água. O simulador deve ser capaz de reproduzir as características de absorção e espalhamento do corpo ou parte do corpo humano em um campo de radiação. As grandezas específicas em TC: índice de kerma livre no ar (Ca,100), índice de kerma no ar ponderado (CW), índice de kerma no volume total (Cvol) e produto kerma no ar-comprimento (PKL) devem ser determinadas e comparadas com os níveis de referência já existentes na literatura. Neste trabalho foi desenvolvido um simulador pediátrico craniano, já que no Brasil os níveis de referência para diagnósticos (NRDs) disponíveis foram determinados baseados em um simulador padrão adulto. O simulador desenvolvido inovou em sua construção apresentando materiais que simulam a calota craniana em osso cortical (alumínio) e osso esponjoso (PVC). O seu interior foi preenchido com água destilada. As dimensões foram escolhidas de acordo com as recomendações da Organização Mundial da Saúde e do International Commission on Radiation Units, para o tamanho da cabeça de uma criança de 0 a 5 anos: 160 mm de diâmetro e 155 mm de altura. A calota craniana tem uma espessura de 4 mm e diâmetro interno de 111,9 mm. Para avaliar seu comportamento foram realizados testes em laboratórios e em feixes clínicos. Os resultados apresentaram uma atenuação de até 23% na utilização dos materiais que simulam a calota craniana evidenciando que os valores adotados para os cálculos de NRD podem estar superestimando a dose recebida por pacientes pediátricos. Percebe-se que a dose recebida em exames de crânio apresenta uma distribuição diferente por ser parcialmente atenuada e/ou retroespalhada pela calota craniana, o que não é considerado ao se utilizar o simulador constituído apenas de PMMA. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
109

Desenvolvimento de um protocolo de calibração utilizando espectrometria e simulação matemática, em feixes padrões de raios x / Development of a calibration protocol using spectrometry and mathematical simulation, in x ray standard beams

SANTOS, LUCAS R. dos 21 November 2017 (has links)
Submitted by Pedro Silva Filho (pfsilva@ipen.br) on 2017-11-21T11:20:13Z No. of bitstreams: 0 / Made available in DSpace on 2017-11-21T11:20:13Z (GMT). No. of bitstreams: 0 / A calibração, por definição, é o processo pelo qual se estabelece uma relação entre valores de medição de um padrão, com as suas respectivas incertezas, e as indicações com as incertezas associadas do instrumento de medição a ser calibrado. Um protocolo de calibração descreve a metodologia a ser aplicada em um processo de calibração. O método escolhido para a obtenção deste protocolo foi o da espectrometria de feixe de raios X associada à simulação pelo método de Monte Carlo, fundamentado no fato de que ambos são considerados métodos absolutos na determinação de parâmetros de feixes de radiação. Neste trabalho foi utilizado o método de Monte Carlo utilizado para obter a função resposta do detector utilizada para a correção dos espectros obtidos do feixe primário de radiação X; deste modo foram calculadas as taxas de kerma destes feixes e comparadas aos valores obtidos com as câmaras de ionização padrão secundário do Laboratório de Calibração de Instrumentos do IPEN (LCI/IPEN). Foram obtidos os coeficientes de calibração para o sistema padrão com diferenças em relação ao fornecido pelo laboratório primário entre 1,3% e 15,3%. Os resultados obtidos indicaram a viabilidade do estabelecimento deste protocolo de calibração utilizando a espectrometria como padrão de referência, com incertezas relativas de 0,62% para k=1. As incertezas associadas ao método proposto foram satisfatórias, para um laboratório padrão secundário e comparáveis a um laboratório primário. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0779 seconds