Front end x-ray beam position monitors at the Canadian Light Source

Smith, Sheldon James 04 October 2006
The development of X-ray Beam Position Monitors (XBPM) used on the Canadian Light Source front ends is described in this thesis, from the design concepts to the practical implementation and commissioning. Surveyed into position to provide a fiducialized point of origin for incoming synchrotron radiation, the primary purpose of the XBPM is to provide a measure of synchrotron beam motion. Currently XBPMs have been installed on three beamlines at the Canadian Light Source, a 2.9 GeV third generation synchrotron radiation source. Two of the XBPMs are comprised of chemical vapour deposition synthetic diamond blades coated with gold and installed on insertion device beamlines, while the third makes use of molybdenum blades for a dipole beamline. By incrementally scanning the blades of the XBPM through the synchrotron beam it is possible to determine the monitors� spatial resolution to beam motion. For the commissioned XBPM a typical spatial resolution of +/- 1 micron of beam motion was achieved; and the thermal power loading capacity has been tested to the 2/5 of maximum value. An independent white beam profiler, comprised of a converter crystal and image acquisition software, was constructed to corroborate the functionality of the XBPM.
2

Front end x-ray beam position monitors at the Canadian Light Source

Smith, Sheldon James 04 October 2006 (has links)
The development of X-ray Beam Position Monitors (XBPM) used on the Canadian Light Source front ends is described in this thesis, from the design concepts to the practical implementation and commissioning. Surveyed into position to provide a fiducialized point of origin for incoming synchrotron radiation, the primary purpose of the XBPM is to provide a measure of synchrotron beam motion. Currently XBPMs have been installed on three beamlines at the Canadian Light Source, a 2.9 GeV third generation synchrotron radiation source. Two of the XBPMs are comprised of chemical vapour deposition synthetic diamond blades coated with gold and installed on insertion device beamlines, while the third makes use of molybdenum blades for a dipole beamline. By incrementally scanning the blades of the XBPM through the synchrotron beam it is possible to determine the monitors� spatial resolution to beam motion. For the commissioned XBPM a typical spatial resolution of +/- 1 micron of beam motion was achieved; and the thermal power loading capacity has been tested to the 2/5 of maximum value. An independent white beam profiler, comprised of a converter crystal and image acquisition software, was constructed to corroborate the functionality of the XBPM.