• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 1
  • Tagged with
  • 11
  • 11
  • 11
  • 9
  • 7
  • 7
  • 7
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The properties of zinc phosphate cement used as a base as compared to that used in crown and bridge work a thesis submitted in partial fulfillment ... in dentistry for children ... /

Chow, May H. January 1949 (has links)
Thesis (M.S.)--University of Michigan, 1949.
2

Desenvolvimento, aplicação e avaliação de um objeto virtual de aprendizagem no conhecimento teórico e desempenho prático de alunos de Odontologia sobre o cimento de fosfato de zinco

Tubelo, Rodrigo Alves January 2015 (has links)
O objetivo do presente estudo foi desenvolver e avaliar um Objeto Virtual de Aprendizagem (OVA) sobre agentes de cimentação com ênfase no Cimento de Fosfato de Zinco (CFZ) e verificar a sua influência no conhecimento teórico e habilidade prática em estudantes de graduação em Odontologia. Foram descritas a metodologia e as ferramentas necessárias para o desenvolvimento do OVA. Foi criado um questionário de avaliação pedagógica e técnica do OVA utilizando a escala Likert (0 nunca e 4 sempre). O OVA foi aplicado em 46 estudantes de graduação em odontologia que foram randomizada em 4 grupos: OVA Imediato (GIOVA n=9), OVA longitudinal (GLOVA n=15) e dois grupos controles sem OVA (GIC n=9 and GLC n=13). Os grupos imediatos tiveram acesso ao OVA ou livro por 20 minutos antes do teste de habilidade, enquanto os grupos longitudinais tiveram acesso por 15 dias. O desenvolvimento do objeto permitiu a criação de uma simulação virtual da manipulação do CFZ. O questionário de avaliação mostrou que aproximadamente 65% dos alunos deram 4 pontos e 14,85% deram 3 pontos. O software utilizado foi capaz de reunir as mídias em um OVA, sendo que esse objeto com simulação virtual sobre o CFZ possui alta taxa de aprovação entre os alunos de odontologia. Um pré e pós-teste de conhecimento teórico e dois testes laboratoriais foram realizados por todos os grupos e avaliados por examinadores cegos. Os estudantes que utilizaram o OVA obtiveram melhores resultados nos testes de habilidade do que seus controles. O pós-teste de conhecimento mostrou diferença estatística nos grupos longitudinais GLC (6.0±1.15) e GLOVA (7.33±1.43). Menor espessura de película foi encontrada com diferença estatística nos grupos que utilizaram o OVA: (GIC 25±9,3) e GIOVA (16,24±5,17); GLC (50±27,08) e GLOVA (22,5±9,65). Os grupos que utilizaram o OVA obtiveram maior tempo de presa do que seus controles, e o grupo imediato mostrou diferença estatística GIC (896±218,90) e GIOVA (1138,5±177,95). O OVA com simulação virtual sobre o CFZ possui alta taxa de aprovação entre os alunos de odontologia. O CFZ manipulado por estudantes que utilizaram o OVA tiveram melhores propriedades mecânicas nos testes laboratoriais. Portanto, os grupos que utilizaram o OVA obtiveram melhor habilidade clínica que seus controles e maior retenção de conhecimento após 15 dias. / The aim of this study was to develop and evaluate a Virtual Learning Object (VLO) on cementing agents with emphasis on Zinc Phosphate Cement (ZPC), verifying its influence in theoretical knowledge and practical ability of dentistry undergraduates. The methodology and tools needed to develop the VLO were described and a pedagogical and technique assessment using the Likert Scale (0 never and 4 always) about the object was created. The VLO was applied to 46 dentistry undergraduates randomized into 4 groups: immediate VLO (GIOVA n=9), longitudinal VLO (GLOVA n=15) and two control groups without VLO (GIC n=9 and GLC n=13). Immediate groups had access to VLO or book for 20 minutes before the skill test, while the longitudinal groups had access to VLO or book for 15 days. The development of the object allowed the creation of a virtual simulation of ZPC manipulation. The questionnaire indicates that, approximately, 65% of students gave 4 points to VLO and 14.85% gave 3 points to it. The software used to construct the VLO enables to gather all media in one object, including the virtual simulation on the ZPC, that has a high approval rating among dentistry undergraduates. Pre and post test theoretical knowledge and two laboratory skill tests were performed by all groups and evaluated by blinded examiners. Students who used the VLO obtained better results in skill tests than their controls. Theoretical knowledge showed statistically significant differences in post-test of longitudinal groups: GLC (6.0 ± 1.15) and GLOVA(7:33 ± 1.43). VLO groups achieved a smaller film thickness in the skill test with statistical difference: (GIC 25 ± 9.3) and GIOVA (16.24 ± 5.17); GLC (50 ± 27.08) and GLOVA (22.5 ± 9.65). The higher setting time occurred in the VLO groups, and the immediate group showed a significant difference: GIC (896 ± 218.90) and GIOVA (1138.5 ± 177.95). The VLO with virtual simulation on ZPC has high approval rating among dentistry undergraduates. The ZPC manipulated by students who used the VLO had better mechanical properties in laboratory tests. Therefore, the groups that used the VLO had better clinical skills than their controls and greater retention of knowledge after 15 days.
3

Desenvolvimento, aplicação e avaliação de um objeto virtual de aprendizagem no conhecimento teórico e desempenho prático de alunos de Odontologia sobre o cimento de fosfato de zinco

Tubelo, Rodrigo Alves January 2015 (has links)
O objetivo do presente estudo foi desenvolver e avaliar um Objeto Virtual de Aprendizagem (OVA) sobre agentes de cimentação com ênfase no Cimento de Fosfato de Zinco (CFZ) e verificar a sua influência no conhecimento teórico e habilidade prática em estudantes de graduação em Odontologia. Foram descritas a metodologia e as ferramentas necessárias para o desenvolvimento do OVA. Foi criado um questionário de avaliação pedagógica e técnica do OVA utilizando a escala Likert (0 nunca e 4 sempre). O OVA foi aplicado em 46 estudantes de graduação em odontologia que foram randomizada em 4 grupos: OVA Imediato (GIOVA n=9), OVA longitudinal (GLOVA n=15) e dois grupos controles sem OVA (GIC n=9 and GLC n=13). Os grupos imediatos tiveram acesso ao OVA ou livro por 20 minutos antes do teste de habilidade, enquanto os grupos longitudinais tiveram acesso por 15 dias. O desenvolvimento do objeto permitiu a criação de uma simulação virtual da manipulação do CFZ. O questionário de avaliação mostrou que aproximadamente 65% dos alunos deram 4 pontos e 14,85% deram 3 pontos. O software utilizado foi capaz de reunir as mídias em um OVA, sendo que esse objeto com simulação virtual sobre o CFZ possui alta taxa de aprovação entre os alunos de odontologia. Um pré e pós-teste de conhecimento teórico e dois testes laboratoriais foram realizados por todos os grupos e avaliados por examinadores cegos. Os estudantes que utilizaram o OVA obtiveram melhores resultados nos testes de habilidade do que seus controles. O pós-teste de conhecimento mostrou diferença estatística nos grupos longitudinais GLC (6.0±1.15) e GLOVA (7.33±1.43). Menor espessura de película foi encontrada com diferença estatística nos grupos que utilizaram o OVA: (GIC 25±9,3) e GIOVA (16,24±5,17); GLC (50±27,08) e GLOVA (22,5±9,65). Os grupos que utilizaram o OVA obtiveram maior tempo de presa do que seus controles, e o grupo imediato mostrou diferença estatística GIC (896±218,90) e GIOVA (1138,5±177,95). O OVA com simulação virtual sobre o CFZ possui alta taxa de aprovação entre os alunos de odontologia. O CFZ manipulado por estudantes que utilizaram o OVA tiveram melhores propriedades mecânicas nos testes laboratoriais. Portanto, os grupos que utilizaram o OVA obtiveram melhor habilidade clínica que seus controles e maior retenção de conhecimento após 15 dias. / The aim of this study was to develop and evaluate a Virtual Learning Object (VLO) on cementing agents with emphasis on Zinc Phosphate Cement (ZPC), verifying its influence in theoretical knowledge and practical ability of dentistry undergraduates. The methodology and tools needed to develop the VLO were described and a pedagogical and technique assessment using the Likert Scale (0 never and 4 always) about the object was created. The VLO was applied to 46 dentistry undergraduates randomized into 4 groups: immediate VLO (GIOVA n=9), longitudinal VLO (GLOVA n=15) and two control groups without VLO (GIC n=9 and GLC n=13). Immediate groups had access to VLO or book for 20 minutes before the skill test, while the longitudinal groups had access to VLO or book for 15 days. The development of the object allowed the creation of a virtual simulation of ZPC manipulation. The questionnaire indicates that, approximately, 65% of students gave 4 points to VLO and 14.85% gave 3 points to it. The software used to construct the VLO enables to gather all media in one object, including the virtual simulation on the ZPC, that has a high approval rating among dentistry undergraduates. Pre and post test theoretical knowledge and two laboratory skill tests were performed by all groups and evaluated by blinded examiners. Students who used the VLO obtained better results in skill tests than their controls. Theoretical knowledge showed statistically significant differences in post-test of longitudinal groups: GLC (6.0 ± 1.15) and GLOVA(7:33 ± 1.43). VLO groups achieved a smaller film thickness in the skill test with statistical difference: (GIC 25 ± 9.3) and GIOVA (16.24 ± 5.17); GLC (50 ± 27.08) and GLOVA (22.5 ± 9.65). The higher setting time occurred in the VLO groups, and the immediate group showed a significant difference: GIC (896 ± 218.90) and GIOVA (1138.5 ± 177.95). The VLO with virtual simulation on ZPC has high approval rating among dentistry undergraduates. The ZPC manipulated by students who used the VLO had better mechanical properties in laboratory tests. Therefore, the groups that used the VLO had better clinical skills than their controls and greater retention of knowledge after 15 days.
4

Desenvolvimento, aplicação e avaliação de um objeto virtual de aprendizagem no conhecimento teórico e desempenho prático de alunos de Odontologia sobre o cimento de fosfato de zinco

Tubelo, Rodrigo Alves January 2015 (has links)
O objetivo do presente estudo foi desenvolver e avaliar um Objeto Virtual de Aprendizagem (OVA) sobre agentes de cimentação com ênfase no Cimento de Fosfato de Zinco (CFZ) e verificar a sua influência no conhecimento teórico e habilidade prática em estudantes de graduação em Odontologia. Foram descritas a metodologia e as ferramentas necessárias para o desenvolvimento do OVA. Foi criado um questionário de avaliação pedagógica e técnica do OVA utilizando a escala Likert (0 nunca e 4 sempre). O OVA foi aplicado em 46 estudantes de graduação em odontologia que foram randomizada em 4 grupos: OVA Imediato (GIOVA n=9), OVA longitudinal (GLOVA n=15) e dois grupos controles sem OVA (GIC n=9 and GLC n=13). Os grupos imediatos tiveram acesso ao OVA ou livro por 20 minutos antes do teste de habilidade, enquanto os grupos longitudinais tiveram acesso por 15 dias. O desenvolvimento do objeto permitiu a criação de uma simulação virtual da manipulação do CFZ. O questionário de avaliação mostrou que aproximadamente 65% dos alunos deram 4 pontos e 14,85% deram 3 pontos. O software utilizado foi capaz de reunir as mídias em um OVA, sendo que esse objeto com simulação virtual sobre o CFZ possui alta taxa de aprovação entre os alunos de odontologia. Um pré e pós-teste de conhecimento teórico e dois testes laboratoriais foram realizados por todos os grupos e avaliados por examinadores cegos. Os estudantes que utilizaram o OVA obtiveram melhores resultados nos testes de habilidade do que seus controles. O pós-teste de conhecimento mostrou diferença estatística nos grupos longitudinais GLC (6.0±1.15) e GLOVA (7.33±1.43). Menor espessura de película foi encontrada com diferença estatística nos grupos que utilizaram o OVA: (GIC 25±9,3) e GIOVA (16,24±5,17); GLC (50±27,08) e GLOVA (22,5±9,65). Os grupos que utilizaram o OVA obtiveram maior tempo de presa do que seus controles, e o grupo imediato mostrou diferença estatística GIC (896±218,90) e GIOVA (1138,5±177,95). O OVA com simulação virtual sobre o CFZ possui alta taxa de aprovação entre os alunos de odontologia. O CFZ manipulado por estudantes que utilizaram o OVA tiveram melhores propriedades mecânicas nos testes laboratoriais. Portanto, os grupos que utilizaram o OVA obtiveram melhor habilidade clínica que seus controles e maior retenção de conhecimento após 15 dias. / The aim of this study was to develop and evaluate a Virtual Learning Object (VLO) on cementing agents with emphasis on Zinc Phosphate Cement (ZPC), verifying its influence in theoretical knowledge and practical ability of dentistry undergraduates. The methodology and tools needed to develop the VLO were described and a pedagogical and technique assessment using the Likert Scale (0 never and 4 always) about the object was created. The VLO was applied to 46 dentistry undergraduates randomized into 4 groups: immediate VLO (GIOVA n=9), longitudinal VLO (GLOVA n=15) and two control groups without VLO (GIC n=9 and GLC n=13). Immediate groups had access to VLO or book for 20 minutes before the skill test, while the longitudinal groups had access to VLO or book for 15 days. The development of the object allowed the creation of a virtual simulation of ZPC manipulation. The questionnaire indicates that, approximately, 65% of students gave 4 points to VLO and 14.85% gave 3 points to it. The software used to construct the VLO enables to gather all media in one object, including the virtual simulation on the ZPC, that has a high approval rating among dentistry undergraduates. Pre and post test theoretical knowledge and two laboratory skill tests were performed by all groups and evaluated by blinded examiners. Students who used the VLO obtained better results in skill tests than their controls. Theoretical knowledge showed statistically significant differences in post-test of longitudinal groups: GLC (6.0 ± 1.15) and GLOVA(7:33 ± 1.43). VLO groups achieved a smaller film thickness in the skill test with statistical difference: (GIC 25 ± 9.3) and GIOVA (16.24 ± 5.17); GLC (50 ± 27.08) and GLOVA (22.5 ± 9.65). The higher setting time occurred in the VLO groups, and the immediate group showed a significant difference: GIC (896 ± 218.90) and GIOVA (1138.5 ± 177.95). The VLO with virtual simulation on ZPC has high approval rating among dentistry undergraduates. The ZPC manipulated by students who used the VLO had better mechanical properties in laboratory tests. Therefore, the groups that used the VLO had better clinical skills than their controls and greater retention of knowledge after 15 days.
5

Avaliação in vitro da microdureza dentinária radícular em dentes bovinos após aplicação de diferentes tratamentos com hipoclorito de sódio associado ou não ao cimento de fosfato de zinco / In vitro evaluation of the root-dentin microhardness of bovine teeth after treatment with sodium hypochlorite associated or not with zinc phosphate

Bechtold, Paola 01 September 2006 (has links)
O objetivo deste estudo foi avaliar o comportamento da dentina radicular bovina frente a duas condições experimentais: a aplicação de soluções de hipoclorito de sódio nas concentrações de 0,5% e 2,5% sobre a superfície da luz radicular e a aplicação das mesmas substâncias seguida do cimento de fosfato de zinco, comparando a microdureza dentinária em duas distâncias em relação à luz do canal, nos terços radiculares. Foram utilizadas 30 raízes de incisivos superiores bovinos. Cada raiz foi seccionada em três posições: terço cervical (C), médio (M) e apical (A). Estas foram submetidas ao teste de microdureza Knoop ( KHN a 100g/15 seg) em duas distâncias, 100 ?m e 300 ?m em relação à luz radicular (momento I). Em seguida receberam um tipo de tratamento formando seis Grupos experimentais: 1A - hipoclorito de sódio a 0,5% , 1B – hipoclorito de sódio a 2,5%,1C – solução fisiológico, 2A – hipoclorito de sódio a 0,5% + fosfato de zinco, 2B – hipoclorito de sódio a 2,5% + fosfato de zinco e 2C – solução fisiológico + fosfato de zinco. Nos Grupos 1A, 1B e 1C após a aplicação das substâncias, as superfícies foram vedadas e decorrida uma semana um novo teste de microdureza Knoop (momento II) foi realizado. Os corpos-de-prova dos Grupos 2A, 2B e 2C receberam as soluções testadas por 60 segundos e em seguida a aplicação do cimento de fosfato de zinco, quando foram vedadas e após uma semana foram submetidos a novo teste de microdureza (momento II). Os corpos-de-prova do Grupo 2A, 2B e 2C foram observados ao MEV na região da interface cimento/dentina. Os resultados foram submetidos à análise de variância com medidas repetidas, pois cada dente foi avaliado em seis combinações entre posição (C, M e A) e distância (100 ?m e 300 ?m) e não apresentaram diferença estatisticamente significante (?=0,05) entre as combinações de posição, distância. Somente houve diferença significante (p=0,0000) quando os valores de KHN foram comparados em relação às distâncias 100 ?m e 300 ?m, sendo que a 300 ?m os valores foram maiores. Assim, os valores referentes aos 3 terços foram agrupados formando uma única média para cada distância. Pelo Teste-t pareado, as médias foram comparadas nos momentos I e II em cada distância e observou-se diferença estatisticamente significante (?=0,05) entre os grupos 1C e 2A (p=0,012 à 100 ?m, p=0,006 à 300 ?m; p=0,024 à 100 ?m e p=0,047 à 300 ?m, respectivamente). Para comparação do comportamento da dentina antes e depois dos tratamentos após uma semana, todas as médias do momento I foram juntadas num único grupo (grupo momento I). A análise de variância o grupo 1C apresentou diferença estatisticamente significante em relação ao grupo formado pelas médias de microdureza no momento I a 100 ?m e 300 ?m; 1B e 2B a 100 ?m e 1B, 2B e 2C a 300 ?m. Com isso, podemos concluir que a dentina radicular sem qualquer tratamento anti-séptico após uma semana apresenta seus valores de microdureza diminuídos de maneira significante em relação às medidas iniciais (I) e aos demais grupos experimentais. / The aim of this study was to evaluate the behavior of the bovine root-dentin under two experimental conditions: the application over the lumen surface with sodium hypochlorite solutions in concentrations of 0,5% and 2,5%, and the application of the same solutions after zinc phosphate cement was applied. The dentin microhardness was compared at two distances from the lumen, in the radicular thirds. In this study, 30 roots of bovine upper incisor were used. Each root was sectioned in the thirds: cervical (C), medium (M) and apical (A), and submitted to the Knoop microhardness test (KHN at 100g/15s) at two distances: 100 ?m and 300 ?m from lumen (I). After that, the species received one type of treatment determining six experimental groups: 1A – sodium hypochlorite 0,5%, 1B - sodium hypochlorite 2,5%, 2C – physiologic solution, 2A - sodium hypochlorite 0,5% + zinc phosphate, 2B - sodium hypochlorite 2,5% + zinc phosphate e 2C - physiologic solution+ zinc phosphate. In the Groups 1A, 1B and 1C after these solutions were applied, surfaces were sealed and one week later a new measure of microhardness (KHN) was taken (II). The Groups 2A, 2B and 2C received the tested solutions for 60 seconds following application of zinc phosphate cement, them they were sealed and after seven days a new measure was taken (II). The samples of Group 2A, 2B and 2C were observed on MEV micrographs in the cement/dentin interface. Analysis of variance with repeated measures, as each tooth was evaluated in six combinations of positions (C, M, A) and distances (100 ?m and 300 ?m), showed that there were no statistical (?=0,05) differences between combinations of position and distance. There was only significant difference (P=0,000) when KHN values were compared in relation to distances (100 and 300?m), and at 300 ?m higher values was found. The values from the thirds were grouped resulting in sole mean for each distance. Pared test-t was run to compare values I and II, in each distance significant difference was found in Group 1C and 2A (P=0,012 at 100, P=0,006 at 300; P=0,024 at 100 e P=0,047 at 300, respectively). To compare dentin behavior pre and post treatments after a week, all averages of values I were joined in a single group (group moment I). Under the Analysis of variance group 1C showed a significant difference in relation to the group formed by averages of microhardness in value I at 100 ?m and 300 ?m; 1B and 2B at 100 ?m and 1B, 2B and 2C at 300 ?m. Therefore, it can be concluded that root dentin with no anti-septic treatment after one week significantly shows decreased values of microhardness in relation to the initial measures (I) and to the others experimental groups.
6

Avaliação da infiltração marginal e da resistência à tração de coroas metálicas após abertura oclusal para terapia endodôntica: estudo in vitro / Evaluation of cast crowns microleakage and retentive strength after occlusal Access for endodontic therapy: in vitro study

Sonoki, Rogério Issao 20 September 2006 (has links)
Este estudo in vitro teve como objetivo determinar a infiltração marginal e resistência à remoção por tração de coroas totalmente metálicas, cimentadas com cimento de fosfato de zinco e que foram submetidas à abertura oclusal para tratamento endodôntico. Foram usados 20 dentes molares (Banco Permanente de Dentes Humanos da FOUSP). Os dentes foram fixados sobre uma base acrílica de secção circular e foram torneados configurando preparos para coroas totais com dimensões de altura e diâmetro padronizadas. Coroas metálicas em Ni Cr foram fundidas através da técnica de enceramento direto e cimentadas com cimento de fosfato de zinco com carga axial de 5 Kg por 10 minutos. Os corpos de prova foram divididos em: Grupos Controle GC1 e GC2, que utilizaram os mesmos corpos de prova, e Grupo Experimental (GE). Todos os corpos de prova foram mantidos em água destilada para que não se desidratassem. Os espécimes dos grupos GC1 e GC2 foram mantidos sem nenhuma intervenção e os do grupo GE foram perfurados com broca de carbide de tungstênio, simulando uma cirurgia de acesso endodôntico. As amostras dos grupos GC2 e GE foram submetidas à ciclagem térmica de 700 ciclos entre 5º e 55º C. Em seguida foram mantidos em uma solução de azul de metileno 0,5%, ph 7,2 por 4 horas a 37º C. Foram submetidos ao ensaio mecânico de tração das coroas em uma máquina universal de ensaios Kratos SV 100, regulada para trabalhar a uma velocidade de ensaio de 0,5 mm/minuto. Os resultados obtidos foram submetidos à análise estatística pelos testes t de Student e as infiltrações avaliadas pela correlação linear de Spearman. A análise inferencial dos resultados dos testes de tração demonstrou com um nível de significância p=0,108, entre os grupos GC1 e GC2, e p=0,502, entre os grupos GC2 e GE, não haver diferença estatisticamente significante. As médias dos valores obtidos nos testes de tração e os seus respectivos desvios padrão foram: GC1 13,96+/-4, 48, GC2 11,26+/-2,269 e GE 10,09+/-4,86 (valores em Kgf). A análise visual subjetiva da infiltração nos corpos de prova indicou que o grupo GE apresentou o maior grau de infiltração marginal com presença do corante atingindo o terço oclusal das paredes axiais (mediana dos scores 3). O grupo GC2 apresentou infiltração marginal no terço médio (mediana dos scores 2). O grupo GC1 apresentou infiltração marginal no terço cervical e médio (mediana dos scores 1). / This in vitro study had the objective to determine the marginal microleakage and the retentive strength of totally metallic crowns, cemented with zinc phosphate cement and subjected to occlusal access for endodontic treatment. 20 human molars (Banco Permanente de Dentes Humanos da FOUSP) have been used for the experiment. The teeth were fixed on a circular acrylic section base and were prepared with standardized dimensions. Metallic crowns in Ni Cr were cast with the direct waxing technique and cemented with zinc phosphate cement with vertical load of 5 kg for 10 minutes. The specimens were divided in groups: Group Control 1 (GP1), Group Control 2 (GP2) and Group Experimental (GE). All the specimens were kept on distillated water so that they wouldn’t dehydrate. The specimens of the groups GC1 and GC2 were kept without any intervention and the ones of the group GE were drilled with a tungstein carbide bur, simulating an endodontic access surgery. Next, the samples of groups GC2 and GE were subjected to a thermal cycling of 700 cycles between 5º and 55º C. To verify the existence of micro infiltration, it was used the methylene blue dye test, 0,5%, ph 7,2 for 4 hours at 37ºC. The specimens were subjected to the load of tension in a universal tensile testing machine Kratos SV 100 at speed 0,5 mm/min. Statistical analyses with t tests showed no significant difference between crown retention before and after endodontic access preparation (p=0,108). The mean displacement forces were: GC1 13,96+/-4,48, GC2 11,26+/-2,269 e GE 10,09+/-4,86 (value in Kgf). With the Spearman’s evaluation test the microleakage was measured. The results showed a greater median of score in GE (score 3). The GC2 and GC1 showed median scores 2 and 1 in order.
7

\"Estudo da evolução da reação de presa do cimento de fosfato de zinco através de luz laser, aplicando a técnica óptica de speckle dinâmico\" / Study of evolution of zinc phosphate cement´s setting reaction by laser, applying an optics technique of dynamic speckle

Kon, Dino Jeiset 09 October 2006 (has links)
A cimentação de próteses e/ou de outros elementos protéticos constituem-se em uma preocupação permanente, já que uma das grandes aplicações do cimento de fosfato de zinco é como agente cimentante. No entanto, a reação de presa do cimento de fosfato de zinco, assim como o tempo de sua presa final, não estão ainda completamente esclarecidos. O presente estudo visa analisar, microestruturalmente, a evolução da reação de presa do cimento de fosfato de zinco. Mais especificamente, buscou-se mensurar, baseado no fenômeno conhecido como speckle dinâmico, o tempo de duração da reação de presa do cimento de fosfato de zinco, desde o momento do término da espatulação até a sua presa completa, em ambiente com temperatura e umidade relativa do ar controlada. A metodologia utilizada consiste na análise do speckle dinâmico obtido através da luz laser, em um ensaio não-destrutivo. A partir dos dados coletados pela técnica óptica de speckle, usando algoritmos computacionais, foi possível estabelecer os coeficientes de correlação temporal e momentos de intensidade. O tratamento estatístico permitiu relacionar e comparar com outros parâmetros tradicionais, químicos e mecânicos macroestruturais já existentes e estudados por outros autores. Pode-se concluir que os resultados alcançados pela nova técnica e pelos métodos convencionais são convergentes. / The prosthesis cementation and/or other prosthetic elements, consists in permanent concern, since one of the major applications of zinc phosphate cement is as lutting agent. This study aims at the microstructural analyze to the evolution of the zinc phosphate cement´s setting reaction. More specifically, searched to verify, based on the known phenomenon as dynamic speckle, how long takes the setting reaction of zinc phosphate cement, since the moment of the ending of the mix until your complete setting, in environment with air relative humidity and temperature controlled. The used methodology consist in the analysis of dynamic speckle gotten through the laser, in a non-destructive assay. From the data supplied by the laser speckle, it was possible to establish the temporal correlation coefficients and intensity moments. The statistical treatment, allowed to compare and relate with other traditional, chemical and mechanical macrostructural parameters, already existing and studied by other authors. It can be conclude that outcomes achieved by the new technique and with the conventional methods are convergent.
8

Resistência à tração de retentores intra-radiculares fundidos sumetidos ao acabamento após cimentação com fosfato de zinco

Iglésias, Michele Andréa Lopes 11 July 2007 (has links)
The refinement of the coronary portion of the intraradicular post cemented constitutes in routine in the clinic. However, the effects of the action of the diamond burn in high rotation on the cement agent are little argued. This study is tested the hypothesis of that the refinement with high rotation an the passed time between the cementation and the accomplishment of the refinement have negative effect in the tensile strength of the intraradicular post cemented in bovine roots. Forty eight bovine roots have been parted with 15mm of length, endodontically treated, confectioned in Cu-Al league, cemented with cement zinc phosphate and divided in 4 experimental groups (n=12). Group A: Without refinement; Group B, C e D submitted the refinement 15, 60 minutes and 24 hours respectively, after the cementation. The assay was carried through in universal machine (EMIC) with speed of 0,5mm/min for all the groups 24 hours after the cementation. The data of tensile strength had been analyzed by the analysis of the variance and test of Bartlet (α=1%). Verified that it did not have significant difference between the groups. Inside of the limitation of this study it can be concluded that the refinement with high rotation and the factor passed time between the cementation and assay did not produce effect of the resistance of the intraradicular posts. / O acabamento da porção coronária do retentor intra-radicular fundido após cimentação constitui-se rotina na clínica odontológica. Entretanto, os efeitos da ação da ponta diamantada em alta rotação sobre o agente cimentante são pouco avaliados. Este estudo testou a hipótese de que o tempo decorrido entre a cimentação e a realização do acabamento com alta rotação tenha efeito negativo na resistência à tração dos retentores intra-radiculares fundidos. Quarenta e oito raízes bovinas foram seccionadas com 15 mm de comprimento, tratadas endodonticamente e divididas aleatoriamente em quatro grupos (n=12): n=A: não submetidos ao acabamento; n=B, C e D submetidos ao acabamento com os tempos de 15, 60 minutos e 24 horas respectivamente, após a cimentação. Os condutos foram moldados pela técnica direta para a obtenção de retentores com 11 mm de comprimento intra-radicular, fundidos em cobre-alumínio, jateados com óxido de alumínio e cimentados com fosfato de zinco. O ensaio de tração foi realizado em máquina universal (EMIC) com velocidade de 0,5mm/min para todos os grupos 24 horas após a cimentação. Os resultados foram submetidos à análise de variância e teste de Bartlet (α=1%). Não houve diferenças estatisticamente significantes na resistência à tração nos grupos controle e os grupos com acabamento após a cimentação, independente do período de espera. Dentro das limitações deste estudo concluiu-se que o acabamento com alta rotação e o tempo decorrido entre a cimentação e o ensaio não produziu efeito sobre a resistência dos retentores intra-radiculares fundidos em cobre-alumínio. / Mestre em Odontologia
9

Avaliação in vitro da microdureza dentinária radícular em dentes bovinos após aplicação de diferentes tratamentos com hipoclorito de sódio associado ou não ao cimento de fosfato de zinco / In vitro evaluation of the root-dentin microhardness of bovine teeth after treatment with sodium hypochlorite associated or not with zinc phosphate

Paola Bechtold 01 September 2006 (has links)
O objetivo deste estudo foi avaliar o comportamento da dentina radicular bovina frente a duas condições experimentais: a aplicação de soluções de hipoclorito de sódio nas concentrações de 0,5% e 2,5% sobre a superfície da luz radicular e a aplicação das mesmas substâncias seguida do cimento de fosfato de zinco, comparando a microdureza dentinária em duas distâncias em relação à luz do canal, nos terços radiculares. Foram utilizadas 30 raízes de incisivos superiores bovinos. Cada raiz foi seccionada em três posições: terço cervical (C), médio (M) e apical (A). Estas foram submetidas ao teste de microdureza Knoop ( KHN a 100g/15 seg) em duas distâncias, 100 ?m e 300 ?m em relação à luz radicular (momento I). Em seguida receberam um tipo de tratamento formando seis Grupos experimentais: 1A - hipoclorito de sódio a 0,5% , 1B – hipoclorito de sódio a 2,5%,1C – solução fisiológico, 2A – hipoclorito de sódio a 0,5% + fosfato de zinco, 2B – hipoclorito de sódio a 2,5% + fosfato de zinco e 2C – solução fisiológico + fosfato de zinco. Nos Grupos 1A, 1B e 1C após a aplicação das substâncias, as superfícies foram vedadas e decorrida uma semana um novo teste de microdureza Knoop (momento II) foi realizado. Os corpos-de-prova dos Grupos 2A, 2B e 2C receberam as soluções testadas por 60 segundos e em seguida a aplicação do cimento de fosfato de zinco, quando foram vedadas e após uma semana foram submetidos a novo teste de microdureza (momento II). Os corpos-de-prova do Grupo 2A, 2B e 2C foram observados ao MEV na região da interface cimento/dentina. Os resultados foram submetidos à análise de variância com medidas repetidas, pois cada dente foi avaliado em seis combinações entre posição (C, M e A) e distância (100 ?m e 300 ?m) e não apresentaram diferença estatisticamente significante (?=0,05) entre as combinações de posição, distância. Somente houve diferença significante (p=0,0000) quando os valores de KHN foram comparados em relação às distâncias 100 ?m e 300 ?m, sendo que a 300 ?m os valores foram maiores. Assim, os valores referentes aos 3 terços foram agrupados formando uma única média para cada distância. Pelo Teste-t pareado, as médias foram comparadas nos momentos I e II em cada distância e observou-se diferença estatisticamente significante (?=0,05) entre os grupos 1C e 2A (p=0,012 à 100 ?m, p=0,006 à 300 ?m; p=0,024 à 100 ?m e p=0,047 à 300 ?m, respectivamente). Para comparação do comportamento da dentina antes e depois dos tratamentos após uma semana, todas as médias do momento I foram juntadas num único grupo (grupo momento I). A análise de variância o grupo 1C apresentou diferença estatisticamente significante em relação ao grupo formado pelas médias de microdureza no momento I a 100 ?m e 300 ?m; 1B e 2B a 100 ?m e 1B, 2B e 2C a 300 ?m. Com isso, podemos concluir que a dentina radicular sem qualquer tratamento anti-séptico após uma semana apresenta seus valores de microdureza diminuídos de maneira significante em relação às medidas iniciais (I) e aos demais grupos experimentais. / The aim of this study was to evaluate the behavior of the bovine root-dentin under two experimental conditions: the application over the lumen surface with sodium hypochlorite solutions in concentrations of 0,5% and 2,5%, and the application of the same solutions after zinc phosphate cement was applied. The dentin microhardness was compared at two distances from the lumen, in the radicular thirds. In this study, 30 roots of bovine upper incisor were used. Each root was sectioned in the thirds: cervical (C), medium (M) and apical (A), and submitted to the Knoop microhardness test (KHN at 100g/15s) at two distances: 100 ?m and 300 ?m from lumen (I). After that, the species received one type of treatment determining six experimental groups: 1A – sodium hypochlorite 0,5%, 1B - sodium hypochlorite 2,5%, 2C – physiologic solution, 2A - sodium hypochlorite 0,5% + zinc phosphate, 2B - sodium hypochlorite 2,5% + zinc phosphate e 2C - physiologic solution+ zinc phosphate. In the Groups 1A, 1B and 1C after these solutions were applied, surfaces were sealed and one week later a new measure of microhardness (KHN) was taken (II). The Groups 2A, 2B and 2C received the tested solutions for 60 seconds following application of zinc phosphate cement, them they were sealed and after seven days a new measure was taken (II). The samples of Group 2A, 2B and 2C were observed on MEV micrographs in the cement/dentin interface. Analysis of variance with repeated measures, as each tooth was evaluated in six combinations of positions (C, M, A) and distances (100 ?m and 300 ?m), showed that there were no statistical (?=0,05) differences between combinations of position and distance. There was only significant difference (P=0,000) when KHN values were compared in relation to distances (100 and 300?m), and at 300 ?m higher values was found. The values from the thirds were grouped resulting in sole mean for each distance. Pared test-t was run to compare values I and II, in each distance significant difference was found in Group 1C and 2A (P=0,012 at 100, P=0,006 at 300; P=0,024 at 100 e P=0,047 at 300, respectively). To compare dentin behavior pre and post treatments after a week, all averages of values I were joined in a single group (group moment I). Under the Analysis of variance group 1C showed a significant difference in relation to the group formed by averages of microhardness in value I at 100 ?m and 300 ?m; 1B and 2B at 100 ?m and 1B, 2B and 2C at 300 ?m. Therefore, it can be concluded that root dentin with no anti-septic treatment after one week significantly shows decreased values of microhardness in relation to the initial measures (I) and to the others experimental groups.
10

\"Estudo da evolução da reação de presa do cimento de fosfato de zinco através de luz laser, aplicando a técnica óptica de speckle dinâmico\" / Study of evolution of zinc phosphate cement´s setting reaction by laser, applying an optics technique of dynamic speckle

Dino Jeiset Kon 09 October 2006 (has links)
A cimentação de próteses e/ou de outros elementos protéticos constituem-se em uma preocupação permanente, já que uma das grandes aplicações do cimento de fosfato de zinco é como agente cimentante. No entanto, a reação de presa do cimento de fosfato de zinco, assim como o tempo de sua presa final, não estão ainda completamente esclarecidos. O presente estudo visa analisar, microestruturalmente, a evolução da reação de presa do cimento de fosfato de zinco. Mais especificamente, buscou-se mensurar, baseado no fenômeno conhecido como speckle dinâmico, o tempo de duração da reação de presa do cimento de fosfato de zinco, desde o momento do término da espatulação até a sua presa completa, em ambiente com temperatura e umidade relativa do ar controlada. A metodologia utilizada consiste na análise do speckle dinâmico obtido através da luz laser, em um ensaio não-destrutivo. A partir dos dados coletados pela técnica óptica de speckle, usando algoritmos computacionais, foi possível estabelecer os coeficientes de correlação temporal e momentos de intensidade. O tratamento estatístico permitiu relacionar e comparar com outros parâmetros tradicionais, químicos e mecânicos macroestruturais já existentes e estudados por outros autores. Pode-se concluir que os resultados alcançados pela nova técnica e pelos métodos convencionais são convergentes. / The prosthesis cementation and/or other prosthetic elements, consists in permanent concern, since one of the major applications of zinc phosphate cement is as lutting agent. This study aims at the microstructural analyze to the evolution of the zinc phosphate cement´s setting reaction. More specifically, searched to verify, based on the known phenomenon as dynamic speckle, how long takes the setting reaction of zinc phosphate cement, since the moment of the ending of the mix until your complete setting, in environment with air relative humidity and temperature controlled. The used methodology consist in the analysis of dynamic speckle gotten through the laser, in a non-destructive assay. From the data supplied by the laser speckle, it was possible to establish the temporal correlation coefficients and intensity moments. The statistical treatment, allowed to compare and relate with other traditional, chemical and mechanical macrostructural parameters, already existing and studied by other authors. It can be conclude that outcomes achieved by the new technique and with the conventional methods are convergent.

Page generated in 0.08 seconds