Wastewater treatment facilities around the world use significant amount of energy which contributes to large quantities of greenhouse gas (GHG) emissions. According to the U.S.EPA, nearly 3% of the USA's energy is used to treat wastewater. This consumption is increasing at faster rates with increase in population and regulations. Wastewater facilities use large number of pumps in their transfer stations, treatment plants, and effluent pump stations. All these pumps consume considerable amounts of energy. This study presents a preliminary energy inspection of two facilities from Louisiana. This audit provides an inventory of the energy consumed for various activities like pumping, treatment, and discharge. This analysis helps the operators to identify the potential power consuming areas and optimize by adopting several energy conservation measures (ECMs). This study also involves the quantification of GHG emissions based on the energy consumption. The benefits of the study include minimizing energy and GHG emission.