Return to search

Avaliação biomecânica de três desenhos de osteotomia sagital do baixo mandibular / Biomechanical evaluation of three different design of sagittal split ostetomy

Orientador: Renato Mazzonetto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-16T19:21:37Z (GMT). No. of bitstreams: 1
Nascimento_FredericoFelipeAntoniodeOliveira_D.pdf: 1284210 bytes, checksum: 45a5dcdf11ad7c9b61752ee6009a3b43 (MD5)
Previous issue date: 2010 / Resumo: A osteotomia sagital do ramo mandibular tem sido o procedimento mais usado por cirurgiões bucomaxilofaciais para a correção de deformidades mandibulares. Numerosas modificações no desenho desta osteotomia têm sido proposta na literatura. O objetivo deste estudo foi avaliar a influência dos diferentes desenhos da osteotomia sagital do ramo mandibular na estabilidade e dissipação de forças através do ramo e corpo mandibular. A amostra total foi composta de 30 hemimandíbulas divididas em três grupos. A modificação proposta por Epker (1977) que corresponde ao grupo I, por Wolford et al (1987) que corresponde ao grupo II e Wyatt (1997) que corresponde ao grupo III, confeccionadas em poliuretano e fixadas com parafusos de titânio em L invertido posicionalmente. Três diferentes tipos de desenhos foram testados. As hemimandíbulas sofreram carregamento linear a uma proporção de 1mm/min analisado pela extensometria e teste de flexão em cada um dos grupos. Os resultados foram analisados estatisticamente e não foi observado diferença estatísticamente significante entre os grupos I e II, mas o grupo III apresentou valores estatísticos menores em relação aos outros grupos. A extensometria mostrou diferenças na distribuição das tensões entre os grupos estudados / Abstract: Bilateral sagittal split ramus osteotomy has been the most surgical procedure performed by oral and maxillofacial surgeons to correct mandibular deficiencies. Numerous design and modifications have been introduced in the literature. The purpose of this study is evaluate different design of sagittal mandibular ramus osteotomy on stability and dispelling forces through the mandibular ramus and body. Three design of sagittal split osteotomy was choiced to this study. The mandible suffered mechanical mastigatory stress analised by strain gauge and bending strength evaluation of each one of these design techniques. The sample of this study were compoud by 30 half mandible confectioned in polyurethane. The half mandible will be fixed with positional titanium screws. The groups were submitted to mechanical bending tests with 1mm/min until the peak load. The results demonstrated no statistical significance between group 1 and 2, but the results demostrated that group III reached inferior values when compared with other groups. Strain gauge tests showed difference on mechanical force distribution between the studied groups / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288683
Date16 August 2018
CreatorsNascimento, Frederico Felipe Antonio de Oliveira
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Mazzonetto, Renato, 1968-2011, Kluppel, Leandro Eduardo, Marquez, Iris Malagoni, Moraes, Marcio de, Henriques, Guilherme Elias Pessanha
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format66 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0087 seconds