Submitted by Fabricia Fialho Reginato (fabriciar) on 2015-06-30T23:58:11Z
No. of bitstreams: 1
ClauberFerasso.pdf: 8384052 bytes, checksum: dc9cfb947f94d52412c3434032ae62da (MD5) / Made available in DSpace on 2015-06-30T23:58:11Z (GMT). No. of bitstreams: 1
ClauberFerasso.pdf: 8384052 bytes, checksum: dc9cfb947f94d52412c3434032ae62da (MD5)
Previous issue date: 2013-08 / FINEP - Financiadora de Estudos e Projetos / A contribuição das fontes de energias alternativas, principalmente a solar térmica, para a diversificação da matriz energética brasileira é importante devido, principalmente, ao aumento da demanda do consumo de energia elétrica, ocasionado pelo progresso e desenvolvimento da população e do País. Parte deste aumento é consequência do uso simultâneo de milhares de chuveiros elétricos, na maioria das vezes no horário de ponta, considerado um dos responsáveis pelo elevado pico na curva de demanda entre 18 e 21 horas. Frente a isso, a utilização da energia solar através de sistemas de aquecimento solar para o uso doméstico, vem ao encontro deste propósito. Após análise do consumo médio mensal de energia elétrica fornecida pela concessionária AES Sul no período de um ano em um conjunto residencial na cidade de Canoas – RS, foi possível estimar o custo da utilização do chuveiro elétrico nesse local, por domicílio, que representa entre 25 a 30 % da fatura de energia elétrica. A produção de energia térmica através de sistemas de aquecimento solar para pré- aquecimento de água quente para uso doméstico foi simulada utilizando-se o software TRNSYS, para diversas configurações de sistemas (área de coletor e capacidade de armazenamento). A relação entre a demanda de energia para aquecimento de água e a energia produzida pelo SAS foi parametrizada utilizando-se o conceito de fração solar mensal e anual. Foi considerada uma temperatura mínima de consumo de água quente de 40 °C e um perfil de consumo correspondente à taxa de ocupação média dos domicílios no local. Os dados climáticos necessários para a simulação foram obtidos a partir do ano meteorológico típico (TMY) para Porto Alegre. Os resultados obtidos das diversas simulações mostraram que é possível obter uma economia direta para consumidor de até 58% de energia consumida pelo chuveiro elétrico e uma economia de energia estimada em 12.399 kWh para o sistema elétrico ao longo de 20 anos. Estes resultados podem ser melhorados com a diminuição do custo unitário do SAS ou através de incentivos decorrentes da diminuição dos custos de ampliação da capacidade da rede elétrica por parte das concessionárias, decorrentes da mudança do perfil de carga do sistema. / The contribution of alternative energy sources, particularly solar thermal, to diversify the Brazilian energy matrix is important, mainly due to increased demand of electricity consumption, caused by the progress and development of the population as well as the country. Part of this increase is a consequence of the simultaneous use of thousands of electric showers, mostly during peak hours, considered one of the chief responsible for the high peak in the demand curve between 6.00 and 9.00PM. Given this, the use of solar energy, through solar heating systems for domestic use, meets this purpose. After the analysis of the average monthly consumption of electricity provided by the supplier AES Sul in the period of one year in a residential complex in the city of Canoas – RS, it was possible to estimate the cost of using electric showers in that location, per household, which was between 25 to 30% of the electricity bill. The production of thermal energy through solar heating systems for preheating domestic hot water was simulated using the TRNSYS software for various system configurations (collector area and storage capacity). The relationship between energy demand for water heating and energy produced by SAS was parameterized using the concept of monthly and annual solar fraction, considering a minimum temperature of hot water of 40 ° C, and a profile of consumption corresponding to the average occupancy rate of households at the site. The climatic data required for the simulation were obtained from the typical meteorological year (TMY) to Porto Alegre and the results of several simulations showed that it is possible to get direct savings to the consumer up to 58% of energy consumed by electric shower and energy savings estimated at 12,399 kWh for the electricity system over a period of 20 years. These results can be improved by reducing the unit cost of SAS or through incentives from lowering the cost of expanding the capacity of the electric grid by suppliers, resulting from the change of the system load profile.
Identifer | oai:union.ndltd.org:IBICT/oai:www.repositorio.jesuita.org.br:UNISINOS/4113 |
Date | 08 1900 |
Creators | Ferasso, Clauber Andre |
Contributors | http://lattes.cnpq.br/9129454582576885, Dias, João Batista, Macagnan, Mario Henrique |
Publisher | Universidade do Vale do Rio dos Sinos, Programa de Pós-Graduação em Engenharia Mecânica, Unisinos, Brasil, Escola Politécnica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UNISINOS, instname:Universidade do Vale do Rio dos Sinos, instacron:UNISINOS |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0027 seconds