Efeito do numero de ciclos de união e separação dos componentes sobre a retenção de sistemas de encaixes para overdentures / Retention force and fatigue strength of overdenture attachment system

Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T11:28:23Z (GMT). No. of bitstreams: 1
Pigozzo_MonicaNogueira_M.pdf: 2354060 bytes, checksum: cc00aca1a1073cf363d5005a5ed1a5d8 (MD5)
Previous issue date: 2007 / Resumo: Este trabalho teve como objetivo avaliar o efeito do número de ciclos de união e separação dos componentes sobre a retenção de 4 sistemas de encaixes para Overdenture do tipo barra-clipe. Foram confeccionados 40 corpos-de-prova, separados em 4 grupos de 10: 1- Conexão Sistema de Prótese (clipe de polímero); 2- Sterngold-Implamed (clipe de polímero); 3- 3i-Implant innovation (clipe metálico); e 4- SIN Sistema de Implante Nacional (clipe metálico). Os corpos-de-prova imersos em saliva artificial foram submetidos ao ensaio de ciclagem mecânica em máquina servohidraúlica MTS-810, realizando-se 5.500 ciclos (união e separação dos componentes) com freqüência de 0,8 Hz. Os valores da força de retenção foram monitorados em 6 registros por meio de ensaio de tração, utilizando o programa Test Work for Test Star com velocidade de 1mm/min, e célula de carga de 1 KN nos períodos: retenção inicial; em 1.100 ciclos de união e separação; 2.200 ciclos; 3.300 ciclos; 4.400 ciclos; e 5.500 ciclos. Os dados obtidos foram submetidos à análise de variância e aplicado o teste de Tukey (p<0,05). Os resultados mostraram que entre os grupos com clipes de polímeros não existiu diferença estatisticamente significante, enquanto os sistemas com clipes metálicos apresentaram diferença estatisticamente significante entre si, exceto após 5.500 ciclos. Os sistemas de retenção da Conexão e 3i apresentaram diferença estatisticamente significante após 4.400 ciclos. Os sistemas de retenção da Conexão e SIN apresentaram diferença estatisticamente significante em todosos ciclos, assim como os da Sterngold-Implamed e SIN. Os sistemas de retenção daSterngold-Implamed e 3i apresentaram diferença estatisticamente significante após 5.500ciclos. Os resultados permitiram concluir que: os sistemas avaliados apresentaram valores de força de retenção considerados satisfatórios em todos os tempos de registro, sendo os mais elevados apresentados pela Conexão e Sterngold-Implamed. Durante o experimento, não ocorreu diminuição nos valores da força de retenção, ou fratura dos componentes, em qualquer sistema avaliado / Abstract: The aim of the present study was to evaluate the effect of the number of insertion and removal cycles on retention force of four Overdenture bar-clip attachment systems. Sample included 40 specimens which were assigned to 4 groups (n=10): 1- Conexão Sistemas de Prótese (polymeric clip); 2- Sterngold-Implamed (polymeric clip); 3- 3i- Implant innovation (metallic clip); and 4- SIN Sistema de Implante Nacional (metallic/metal clip). Specimens immersed in artificial saliva were tested to 5.500 cycles at 0.8 Hz using a servohydraulic machine (MTS-810). During the test, retention force values were recorded 6 times using the tensile test (Test Works for Test Star) at a speed of 1mm/min, with a load cell of 1 KN: initial retention force; at 1100 insertion and removal cycles; 2200 cycles; 3300 cycles; 4400 cycles; and 5500 cycles). Data were submitted to analysis of variance (ANOVA) and Tukey test (p<0.05). No statistically significant difference was observed for the groups using polymeric clips; however, those using metallic clips showed significant difference, except after 5500 cycles. Conexão and 3i attachment systems showed statistically significant difference after 4400 cycles. Comparison between Conexão and SIN Systems and Sterngold-Implamed and SIN demonstrated significant difference at all cycles. Sterngold-Implamed and 3i systems showed statistically significant difference only after 5500 cycles. Results showed that the systems evaluated displayed satisfactory retention force values at all cycling periods tested, with the highest values observed for Conexão and Sterngold-Implamed. No component fractures or reduction in retention force values was found for any of the systems tested. / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289910
Date23 February 2007
CreatorsPigozzo, Monica Nogueira
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Mesquita, Marcelo Ferraz, 1967-, Vaz, Luiz Geraldo, Consani, Rafael Leonardo Xediek
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format123p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds