Made available in DSpace on 2014-12-17T14:55:41Z (GMT). No. of bitstreams: 1
AlvaroMA_DISSERT.pdf: 1811875 bytes, checksum: d1a8b9710060f420383a8d715381bfb9 (MD5)
Previous issue date: 2009-12-23 / Embedded systems are widely spread nowadays. An example is the Digital Signal Processor (DSP), which is a high processing power device. This work s contribution consist of exposing DSP implementation of the system logic for detecting leaks in real time. Among the various methods of leak detection available today this work uses a technique based on the pipe pressure analysis and usesWavelet Transform and Neural Networks. In this context, the DSP, in addition to do the pressure signal digital processing, also communicates to a Global Positioning System (GPS), which helps in situating the leak, and to a SCADA, sharing information. To ensure robustness and reliability in communication between DSP and SCADA the Modbus protocol is used. As it is a real time application,
special attention is given to the response time of each of the tasks performed by the DSP. Tests and leak simulations were performed using the structure of Laboratory of Evaluation of Measurement in Oil (LAMP), at Federal University of Rio Grande do Norte (UFRN) / Os sistemas embarcados est?o amplamente difundidos atualmente. Um exemplo ? o Digital Signal Processor (DSP), que ? um dispositivo com alto poder de processamento. A contribui??o deste trabalho consiste na implementa??o em DSP da l?gica de um sistema de detec??o de vazamentos em tempo real. Dentre os v?rios m?todos de detec??o de vazamentos existentes atualmente este trabalho se desenvolve utilizando uma t?cnica baseada na an?lise da press?o no duto e que utiliza Transformada Wavelet e Redes Neurais. Nesse contexto o DSP, al?m de realizar o processamento digital do sinal de press?o, tamb?m comunica-se com um Global Positioning System (GPS), que auxilia na localiza??o do vazamento e com um sistema supervis?rio, disponibilizando informa??es para este.
Para garantir robustez e confiabilidade na comunica??o entre DSP e sistema supervis?rio ? utilizado o protocolo Modbus. Como trata-se de uma aplica??o de tempo real, uma aten??o
especial ? dada ao tempo de resposta de cada uma das tarefas realizadas pelo DSP. Os testes e simula??es de vazamentos foram realizados utilizando a estrutura do Laborat?rio de Avalia??o de Medi??o em Petr?leo (LAMP), da Universidade Federal do Rio Grande do Norte (UFRN)
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufrn.br:123456789/15304 |
Date | 23 December 2009 |
Creators | Avelino, ?lvaro Medeiros |
Contributors | CPF:51618362968, http://lattes.cnpq.br/7865065553087432, Maitelli, Andr? Laurindo, CPF:42046637100, http://lattes.cnpq.br/0477027244297797, Paiva, Jos? Alvaro de, CPF:79173497487, http://lattes.cnpq.br/6136888701626547, Menezes Filho, Jos? Bezerra de, CPF:11220139491, http://lattes.cnpq.br/4990277801207675, Salazar, Andr?s Ortiz |
Publisher | Universidade Federal do Rio Grande do Norte, Programa de P?s-Gradua??o em Engenharia El?trica, UFRN, BR, Automa??o e Sistemas; Engenharia de Computa??o; Telecomunica??es |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | application/pdf |
Source | reponame:Repositório Institucional da UFRN, instname:Universidade Federal do Rio Grande do Norte, instacron:UFRN |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0017 seconds