Implementa??o de um M?dulo de Supervis?o para um Sistema de Detec??o de Vazamentos em Dutos de Petr?leoSilva, Rodrigo Eduardo Ferreira da 22 December 2009 (has links)
Made available in DSpace on 2014-12-17T14:08:36Z (GMT). No. of bitstreams: 1
RodrigoEFS_DISSERT.pdf: 3471454 bytes, checksum: 0d90f092b5f26fd304c7c8d8252178a4 (MD5)
Previous issue date: 2009-12-22 / The transport of fluids through pipes is used in the oil industry, being the pipelines an important link in the logistics flow of fluids. However, the pipelines suffer deterioration in their walls caused by several factors which may cause loss of fluids to the environment, justifying the investment in techniques and methods of leak detection to minimize fluid loss and environmental damage. This work presents the development of a supervisory module in order to inform to the operator the leakage in the pipeline monitored in the shortest time possible, in order that the operator log procedure that entails the end of the leak. This module is a component of a system designed to detect leaks in oil pipelines using sonic technology, wavelets and neural networks. The plant used in the development and testing of the module presented here was the system of tanks of LAMP, and its LAN, as monitoring network. The proposal consists of, basically, two stages. Initially, assess the performance of the communication infrastructure of the supervisory module. Later, simulate leaks so that the DSP sends information to the supervisory performs the calculation of the location of leaks and indicate to which sensor the leak is closer, and using the system of tanks of LAMP, capture the pressure in the pipeline monitored by piezoresistive sensors, this information being processed by the DSP and sent to the supervisory to be
presented to the user in real time / O transporte de fluidos atrav?s de tubula??es ? utilizado na ind?stria petrol?fera, sendo os dutos um elo importante na log?stica de escoamento de fluidos. Por?m, os dutos sofrem
deteriora??o em suas paredes ocasionadas por diversos fatores o que pode provocar a perda de fluidos para o meio exterior, justificando o investimento em t?cnicas e m?todos de detec??o de vazamentos para minimizar a perda do fluido e os danos ambientais provocados. Este trabalho apresenta o desenvolvimento de um m?dulo de supervis?o para que seja informado ao operador a ocorr?ncia de vazamento no duto monitorado no menor tempo poss?vel, com o prop?sito que o operador efetue procedimentos que acarretem no fim do vazamento. Esse m?dulo ? um componente de um sistema que visa ? detec??o de vazamento em dutos petrol?feros utilizando tecnologia s?nica, wavelets e redes neurais. A planta utilizada no desenvolvimento e testes do m?dulo aqui apresentado, foi o sistema de tanques do Laborat?rio de Avalia??o de Medi??o em Petr?leo (LAMP), e a sua Local Area Network (LAN), como rede de supervis?o. A proposta consiste, basicamente, de duas etapas. Inicialmente, avaliar o desempenho da infraestrutura de comunica??o do m?dulo de supervis?o. Posteriormente, simular vazamentos para que o DSP (Digital Signal Processor) envie informa??es para o supervis?rio realizar o c?lculo da localiza??o
dos vazamentos e indicar a qual sensor o vazamento ? mais pr?ximo, e usando o sistema de tanques do LAMP, capturar a press?o no duto monitorado atrav?s de sensores piezoresistivos,
sendo essa informa??o processada pelo DSP e enviada ao supervis?rio para que seja apresentado ao usu?rio dados em tempo real
|
2 |
Processamento embarcado aplicado a um sistema de detecc?o de vazamentosAvelino, ?lvaro Medeiros 23 December 2009 (has links)
Made available in DSpace on 2014-12-17T14:55:41Z (GMT). No. of bitstreams: 1
AlvaroMA_DISSERT.pdf: 1811875 bytes, checksum: d1a8b9710060f420383a8d715381bfb9 (MD5)
Previous issue date: 2009-12-23 / Embedded systems are widely spread nowadays. An example is the Digital Signal Processor (DSP), which is a high processing power device. This work s contribution consist of exposing DSP implementation of the system logic for detecting leaks in real time. Among the various methods of leak detection available today this work uses a technique based on the pipe pressure analysis and usesWavelet Transform and Neural Networks. In this context, the DSP, in addition to do the pressure signal digital processing, also communicates to a Global Positioning System (GPS), which helps in situating the leak, and to a SCADA, sharing information. To ensure robustness and reliability in communication between DSP and SCADA the Modbus protocol is used. As it is a real time application,
special attention is given to the response time of each of the tasks performed by the DSP. Tests and leak simulations were performed using the structure of Laboratory of Evaluation of Measurement in Oil (LAMP), at Federal University of Rio Grande do Norte (UFRN) / Os sistemas embarcados est?o amplamente difundidos atualmente. Um exemplo ? o Digital Signal Processor (DSP), que ? um dispositivo com alto poder de processamento. A contribui??o deste trabalho consiste na implementa??o em DSP da l?gica de um sistema de detec??o de vazamentos em tempo real. Dentre os v?rios m?todos de detec??o de vazamentos existentes atualmente este trabalho se desenvolve utilizando uma t?cnica baseada na an?lise da press?o no duto e que utiliza Transformada Wavelet e Redes Neurais. Nesse contexto o DSP, al?m de realizar o processamento digital do sinal de press?o, tamb?m comunica-se com um Global Positioning System (GPS), que auxilia na localiza??o do vazamento e com um sistema supervis?rio, disponibilizando informa??es para este.
Para garantir robustez e confiabilidade na comunica??o entre DSP e sistema supervis?rio ? utilizado o protocolo Modbus. Como trata-se de uma aplica??o de tempo real, uma aten??o
especial ? dada ao tempo de resposta de cada uma das tarefas realizadas pelo DSP. Os testes e simula??es de vazamentos foram realizados utilizando a estrutura do Laborat?rio de Avalia??o de Medi??o em Petr?leo (LAMP), da Universidade Federal do Rio Grande do Norte (UFRN)
|