The technique of the distributed fiber optic sensor system, the principle that we use Sagnac interferometer to sense time-varying physical field, can be used to measure the position of the disturbed physical field and have the ability of detecting continuous position. Based on the configuration of the Sagnac interferometer, sensing optic fiber is loop design, which is hard to be set in real surroundings, and a half length of loop fiber have to be the isolated protection of the physical field. Therefore, this essay brings up the In-Line conception to be the design direction. And we make use of the physical field of pipeline leak acoustic to detect disturbance position. The measurable range of systematic structure signal is 3¡Ñ10-4 ~ 3¡Ñ10-2 , and the dynamic range is 40 dB. On the other hand, the structure of polarization insensitive is brought up, the measurable range is 1.5¡Ñ10-3 ~ 3¡Ñ10-2 , and the dynamic range is 26 dB.