Return to search

Monte Carlo simulation and resolution study of the η → e+e− decay in the WASA-at-COSY detector / Monte Carlo simulering och upplösningsstudier av sönderfallet η → e+e− i WASA-at-COSY detektorn

A comparative study is done on the Mini Drift Chamber (MDC) and the Scintillating Electromagnetic Calorimeter (SEC), two main components of the WASA detector. The purpose of the study is to determine the most effective way to calculate the mass of the η−meson by determining the invariant mass of the final products in the η → e+e− decay. When calculating the invariant mass of the lepton pair the distribution from the MDC had a standard deviation of σMDC = (4.212 ± 0.080) · 10−2 GeV/c2 and from the SEC σSEC = (3.563±0.011)·10−2 GeV/c2. To get a precise measurement, events with a lepton scattering at a polar angle below 30◦ have to be rejected, and to achieve highest precision, it is favorable to use the SEC for momenta above 0.28 GeV/c and the MDC below, respectively. In this study, a combined method is developed which results in an invariant mass resolution of σMix = (3.341±0.012)·10−2 GeV/c2. Thus, the combined method gives a small improvement compared to using the SEC alone, but a considerable improvement compared to using only the MDC.

Identiferoai:union.ndltd.org:UPSALLA1/oai:DiVA.org:uu-229749
Date January 2014
CreatorsIkegami Andersson, Walter Kenji
PublisherUppsala universitet, Kärnfysik
Source SetsDiVA Archive at Upsalla University
LanguageEnglish
Detected LanguageEnglish
TypeStudent thesis, info:eu-repo/semantics/bachelorThesis, text
Formatapplication/pdf
Rightsinfo:eu-repo/semantics/openAccess
RelationFYSAST ; FYSKAND1025

Page generated in 0.0023 seconds