Orientador: Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-07T08:45:44Z (GMT). No. of bitstreams: 1
Higa_MarciaFernanda_M.pdf: 694032 bytes, checksum: 6aeb2dc109b978afe0fa9cd54037a168 (MD5)
Previous issue date: 2005 / Resumo: O presente trabalho teve como objetivo principal a investigação do potencial de utilização de reatores de lodos ativados intermitentes para o tratamento conjunto de diversos tipos de águas residuárias geradas na indústria de catalisadores químicos Degussa, localizada no município de Americana - SP, incluindo-se os esgotos sanitários. Foram utilizados reatores de bancada e estudadas duas idades de lodo, simulando-se a aeração convencional e aeração prolongada. Foram investigados também quatro cenários possíveis, ou seja, quatro amostras compostas distintas de efluentes, de serem implantados em escala real. Os resultados obtidos mostraram que o sistema de aeração prolongada foi preferível em todas as situações estudadas, e que três dos cenários foram adequados ao tratamento biológico de lodos ativados por batelada, uma vez que apresentaram eficiências de redução dos valores de DQO superiores à 80%. No caso do tratamento conjunto de todas as águas residuárias da indústria, essa eficiência foi de 85,7 e 92,1% para as idades de lodo de 7 e 20 dias, respectivamente, indicando que o uso de reatores biológicos de lodos ativados por batelada constituiu-se em alternativa viável para a Degussa / Abstract: The present work had as main objective the investigation of the utilization potential of activated sludge sequencing batch reactors on the combined treatment of several kinds of wastewaters originated in the chemical catalyst industry Degussa, located in Americana - SP, including the domestic sewage. Workbench reactors were used and two sludge ages were studied, simulating the conventional and the prolonged aerations. Four possible sceneries, or four different effluent compound samples, possible of being full-scale introduced, were also investigated. The results showed that the system of prolonged aeration was preferable in alI the studied situations, and that three of the sceneries were suitable for the biological treatment by activated sludge using sequencing batch reactors, once they achieved efficiencies of reduction in the COD values greater than 80%. In the treatment inc1uding the total reunion of the industry effluents, this efficiency was 85,7 and 92,1%, to the sludge age of 7 and 20 days, respectively, indicating that the use of activated sludge sequencing batch biological reactors is a feasible alternative for Degussa / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/258254 |
Date | 23 February 2005 |
Creators | Higa, Marcia Fernanda |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Mendes, Carlos Gomes da Nave, 1958-, Guimarães, José Roberto, Salvador, Nemésio Neves Batista |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Engenharia Civil |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 105p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.002 seconds