1

Design Considerations for Extended Aeration-Denitrification Facilities

Huttner, Frank Paul 01 January 1974 (has links) (PDF)
Design considerations and operating procedures were investigated for nitrogen removal in an extended aeration-denitrification facility. Both past and present removal efficiencies were evaluated for the facility, along with capital and operating cost data. The findings of this research indicate that at very long detention times, significant nitrification and denitrification occurred in the plant without the use of chemicals. Overall nitrogen, BOD5, and suspended solids removals were extremely high. The significance of this research is that future plants may achieve high rates of nitrogen removal through innovative design and operating procedures without the use of costly chemicals. However, capital costs needed to achieve longer detention items will have to be evaluated for the individual plant.
2

Sistema combinado filtro anaerobio-biofiltro aerado submerso : avaliação da partida e da nitrificação de esgoto sanitario / Anaerobic filter-aerated submerged biological filter combined system: start-up and nitrification evaluation in sanitary wastewater

Domingues, Ligia Maria 21 February 2005 (has links)
Orientador: Edson Aparecido Abdul Nour / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-07T10:54:06Z (GMT). No. of bitstreams: 1 Domingues_LigiaMaria_M.pdf: 3689935 bytes, checksum: 34e7505224ee444054fb9606a9599e36 (MD5) Previous issue date: 2005 / Resumo: Este trabalho fundamentou-se na concepção, construção e operação de um sistema combinado anaeróbio-aeróbio, constituído de filtro anaeróbio (FA) e biofiltro aerado submerso (BAS), em escala de laboratório, aplicado ao tratamento de esgoto sanitário. Para atingir o objetivo principal de avaliar o desempenho global do sistema, o trabalho foi dividido em 3 etapas: estudo hidrodinâmico, avaliação da partida e avaliação da nitrificação em diferentes TDH. Baseado numa rotina de monitoramento dos parâmetros físicos, químicos e microbiológicos foi possível avaliar e adequar as condições requeridas para a nitrificação. Verificou-se o desempenho do sistema para diferentes taxas de carregamento volumétrico orgânico e de amônia, relacionando-o com as populações de bactérias nitrificadoras existentes. Constatou-se que remoção de matéria orgânica alcançada foi equivalente para os TDH de 8h (média de 86 ± 6 % para 1,89 ± 0,61 kg DQO/m3.dia com DQO efluente de 87 ± 46 mg O2/L) e 10h (média de 87 ± 4 % para 1,88 ± 0,83 kg DQO/m3 dia com DQO efluente de 89 ± 32 mg O2/L). Para TDH total de 8h (4h de aeração) e taxa de carregamento volumétrico de amônia de 0,33 ± 0,05 kg /m3.dia no BAS a remoção de amônia foi de 27 ± 14 % e a nitrificação completa foi de 20 ± 8 %, para 108 oxidadoras da amônia/g STV e 107 oxidadoras do nitrito/g STV. Para TDH total de 10h (5h de aeração) e taxa de carregamento volumétrico de amônia de 0,39 ± 0,10 kg /m3.dia no BAS a remoção de amônia foi de 47 ± 20 % e a nitrificação foi de 40 ± 19 %, para 1012 oxidadoras da amônia/g STV e 107 oxidadoras do nitrito/g STV. A concepção do sistema FA-BAS operando com TDH de 10 h foi adequada à nitrificação, quando aplicada ao tratamento de esgoto doméstico com média concentração de amônia (em torno de 30 mg/L). Indicou ainda ter grande potencial para tratar esgoto com maior concentração de amônia (acima de 50 mg/L) / Abstract: The present project was based on the conception, construction and operation of an anaerobic-aerobic combined system. This was formed by an anaerobic filter (AF) and an aerated submerged biofilter (ASB), in a laboratory scale, and used for sanitary wastewater. The main objective of this project was to analyze the general performance of the system, and for that, it was divided in 3 parts: hydrodynamic study, start-up evaluation and nitrification analysis in different HRT. Based on a frequent monitoring of physical, chemical and microbiological parameters, it was possible to evaluate and adequate the required conditions for nitrification. The performance of the system for different organic and ammonia volumetric loading rates were verified. Afterwards it was related to the populations of nitrifying bacteria. The system demonstrated organic matter removal not only for HRT of 8 h (average of 86 ± 6% for 1,89 ± 0,61 kg COD/m3.day, with effluent COD of 87 ± 46 mg O2/L) but also for HRT of 10 h (average of 87 ± 4 % for 1,88 ± 0,83 kg COD/m3.day, with effluent COD of 89 ± 32 mg O2/L). For total HRT of 8 h (4 h of aeration) and volumetric loading rates of ammonia of 0,33 ± 0,05 kg/m3.day at ASB, the ammonia removal was 27 ± 14% and the complete nitrification was 20 ± 8 %, for 108 ammonium oxidizers/g TSV and 107 nitrite oxidizers/g TSV. For total HRT of 10 h (5 h of aeration) and volumetric loading rates of ammonia of 0,39 ± 0,10 kg/m3.day at ASB, the ammonia removal was 47 ± 20 % and the complete nitrification was 40 ± 19 %, for 1012 ammonium oxidizers/g TSV and 107 nitrite oxidizers/g TSV. The system AF-ASB operated with HRT of 10 h demonstrated to be useful for nitrification if applied to sewage treatment with average concentration of ammonia (around 30 mg/L). It can also be pointed out that the system can be used to treat sewage with higher concentrations (over 50 mg/L) / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
3

A Proposed Approach to Protect Wastewater Biological Treatment Plants Against Toxic Contaminants

Phillips, Joseph M. 01 January 1972 (has links) (PDF)
No description available.
4

Pos-tratamento de efluente anaerobio por filtros de areia / Post-treatment of anaerobic reactor effluent by sand filters

Tonetti, Adriano Luiz, 1973- 13 February 2004 (has links)
Orientador: Bruno Coraucci Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-04T21:31:46Z (GMT). No. of bitstreams: 1 Tonetti_AdrianoLuiz_M.pdf: 4911696 bytes, checksum: 17f72ad475f9781c9cc0c2be169415a9 (MD5) Previous issue date: 2004 / Resumo: O objetivo deste projeto foi estudar os filtros de areia como um método de baixo custo para o pós-tratamento de filtros anaeróbios alimentados com esgoto sanitário. Nesta pesquisa buscou-se contribuir com o desenvolvimento deste sistema avaliando-se a eficiência de tratamento de quatro filtros de areia com diferentes profundidades de leitos (0,25; 0,50, 0,75 e 1,00 m). A alimentação era proveniente de reatores anaeróbios e foram empregadas cinco cargas diferentes de aplicação (20, 40, 60, 80 e 100 Lm-2). Cada uma delas dispostas diariamente pelo período de um mês. O esgoto bruto, afluente e efluente dos filtros de areia foram analisados semanalmente, permitindo constatar que no emprego de baixas cargas de efluente anaeróbio o sistema propiciava uma remoção superior a 96% da DBO, adequação na emissão de coliformes totais e completa nitrificação. Aumentando-se as cargas, ocorria uma pequena redução da eficiência, no entanto os resultados ainda eram satisfatórios / Abstract: The aim of this project was to study sand filters as a low cost method in the post treatment of upflow anaerobic filter effluent, fed by municipal wastewater. This research intends to contribute with the development of this system estimating the efficiency of the treatment of four sand filters with different depths of the sand layer (0,25; 0,50, 0,75 e 1,00 m). The feed (I think it's influent) was from the four upflow anaerobic filters. Five hydraulic loads (20, 40, 60, 80 e 100 Lm-2) were used to apply the effluent on the sand filters. Each one was applied for one month and later the frequency was increased for two and tree times per day. The municipal wastewater, influent and the effluent of the sand filter were weekly analyzed allowing to conclude that the treatment system had good removal of BOD, COD, TOC, nutrients and microorganisms like total and fecal coli forms. The effluent was good to be disposed or to reused. / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
5

Estudo de tratabilidade de efluentes de industria de catalisadores quimicos por lodos ativados por batelada (LAB) : Degussa, Americana, SP / Treatment study of effluents from chemical catalyst industry by activated sludge using sequencing batch reactor: Degussa, Americana, SP, Brrazil

Higa, Marcia Fernanda 23 February 2005 (has links)
Orientador: Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-07T08:45:44Z (GMT). No. of bitstreams: 1 Higa_MarciaFernanda_M.pdf: 694032 bytes, checksum: 6aeb2dc109b978afe0fa9cd54037a168 (MD5) Previous issue date: 2005 / Resumo: O presente trabalho teve como objetivo principal a investigação do potencial de utilização de reatores de lodos ativados intermitentes para o tratamento conjunto de diversos tipos de águas residuárias geradas na indústria de catalisadores químicos Degussa, localizada no município de Americana - SP, incluindo-se os esgotos sanitários. Foram utilizados reatores de bancada e estudadas duas idades de lodo, simulando-se a aeração convencional e aeração prolongada. Foram investigados também quatro cenários possíveis, ou seja, quatro amostras compostas distintas de efluentes, de serem implantados em escala real. Os resultados obtidos mostraram que o sistema de aeração prolongada foi preferível em todas as situações estudadas, e que três dos cenários foram adequados ao tratamento biológico de lodos ativados por batelada, uma vez que apresentaram eficiências de redução dos valores de DQO superiores à 80%. No caso do tratamento conjunto de todas as águas residuárias da indústria, essa eficiência foi de 85,7 e 92,1% para as idades de lodo de 7 e 20 dias, respectivamente, indicando que o uso de reatores biológicos de lodos ativados por batelada constituiu-se em alternativa viável para a Degussa / Abstract: The present work had as main objective the investigation of the utilization potential of activated sludge sequencing batch reactors on the combined treatment of several kinds of wastewaters originated in the chemical catalyst industry Degussa, located in Americana - SP, including the domestic sewage. Workbench reactors were used and two sludge ages were studied, simulating the conventional and the prolonged aerations. Four possible sceneries, or four different effluent compound samples, possible of being full-scale introduced, were also investigated. The results showed that the system of prolonged aeration was preferable in alI the studied situations, and that three of the sceneries were suitable for the biological treatment by activated sludge using sequencing batch reactors, once they achieved efficiencies of reduction in the COD values greater than 80%. In the treatment inc1uding the total reunion of the industry effluents, this efficiency was 85,7 and 92,1%, to the sludge age of 7 and 20 days, respectively, indicating that the use of activated sludge sequencing batch biological reactors is a feasible alternative for Degussa / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
6

Remoção de helmintos e protozoarios em sistema de tratamento filtro anaerobio- filtro de areia visando uso agricola / Helminths and protozoans removal in treatment of anaerobic filter- sand filter system focusing agricultural use

Kanegae, Alexandre Patto 17 March 2005 (has links)
Orientador: Bruno Coraucci Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-09T15:44:03Z (GMT). No. of bitstreams: 1 Kanegae_AlexandrePatto_M.pdf: 1125389 bytes, checksum: dc519b3abb15e2a72d094f64448f7383 (MD5) Previous issue date: 2005 / Resumo: Este trabalho foi desenvolvido com o intuito de se verificar a utilização de filtros de areia, como um sistema de pós-tratamento de efluentes de filtros anaeróbios na remoção de organismos patogênicos presentes nos esgotos, tais como protozoários e helmintos. Para tanto, foi feita a verificação das melhores taxas de aplicação de efluente de filtro anaeróbio em 4 filtros de areia, com profundidades de 0,25; 0,50; 0,75 e 1,00 m. As taxas de aplicação foram de 20, 40, 60, 80 e 100 Lm-2dia -1. O tempo do experimento foi de Maio de 2003 a Agosto de 2004. Para verificação dos organismos presentes no efluente utilizou-se a metodologia adotada pela Cetesb, descrita pela norma L5.550 (1989) - Hoffman modificado e os resultados foram expressos em número de organismos/L. Os resultados demonstraram que o processo de tratamento biológico ocorrido nos filtros de areia com leito mais profundo (1,00 m) foi o que apresentou melhor performance. Não houve correlação entre o número de organismos encontrados e as taxas aplicadas, mas o valor estipulado pela NBR 7229 (1993) de 100 Lm-2dia-1 de efluente aplicado, apresentou resultados satisfatórios / Abstract: This project was developed with the aim of verifying the use of sand filters as a post treatment system of effluents from anaerobic filters. Most of the pathogens found in the wastewater can be classified as protozoans and helminths. For that, the best application rates of anaerobic effluent were studied in four sand filters. They were 0,25; 0,50; 0,75 and 1,00 m deep. The application rates were 20, 40,60,80 e 100 Lm-2day-1. The experiment was run from May 2003 to August 2004. To verify the presence of the organisms in the wastewater, the methodology adopted by Cetesb was used (described as Standard L5.550, 1989) - Hoffman modified and the results were expressed in number or organisms/L. The results show that the biological process of treatment occurred in the deepest sand filter (1,00 m) was the one which presented the best performance. There was no correlation between the number of microorganisms found and the applied rates but, the value established by NBR 7229 (1993) of 100 Lm-2day-1 of effluent presented satisfactory results / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil

Page generated in 0.132 seconds