Return to search

Adapatação cultural e avaliação das propriedades de medida da "Self_Efficacy for Appropriate Medication Adherence Scale - SEAMS" / Cultural adaptation and evaluation of measurement of "Self-Efficacy for Appropriate Medication Adherence Scale - SEAMS"

Orientador: Roberta Cunha Matheus Rodrigues / Texto em português e inglês / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Enfermagem / Made available in DSpace on 2018-08-25T10:11:00Z (GMT). No. of bitstreams: 1
SantosPedrosa_RafaelaBatistados_M.pdf: 1805803 bytes, checksum: 1c035d3233cb182bbb25a113e1cc2f2f (MD5)
Previous issue date: 2014 / Resumo: Este estudo tem como objetivo disponibilizar uma versão da Self-efficacy for Appropriate Medication Adherence Scale ¿ SEAMS para a cultura brasileira e avaliar suas propriedades de medida quando aplicada em pacientes com doença arterial coronária (DAC) em seguimento ambulatorial.. O processo de adaptação cultural foi realizado de acordo com as etapas propostas na literatura - tradução, síntese, retrotradução, avaliação por comitê de especialistas e pré-teste, seguidos pela avaliação da praticabilidade, aceitabilidade, confiabilidade e validade. Fizeram parte deste estudo 147 pacientes com DAC em uso de medicamentos cardioprotetores e de alívio dos sintomas, em seguimento ambulatorial em hospital universitário do interior do estado de São Paulo. Os dados foram obtidos por meio de entrevista e aplicação de instrumento de caracterização sociodemográfica/clínica e das versões brasileiras da Morisky Self-Reported Measure of Medication Adherence Scale (MMAS-4), da General Perceived Self-Efficacy Scale (GSE) e da SEAMS. A praticabilidade foi avaliada pelo tempo despendido na entrevista e a aceitabilidade pela proporção de pacientes que responderam a todos os itens do instrumento. Foi estimada a confiabilidade no que se refere à consistência interna e estabilidade da medida. A validade de construto foi estimada pela evidência correlacional entre os escores da versão brasileira da SEAMS, da MMAS-4 e da GSE. A validade de grupos conhecidos foi testada entre aqueles classificados com "dose suficiente" e "dose insuficiente" ( medida da proporção de adesão) e entre aqueles "aderentes" e "não aderentes" (medida da avaliação global da adesão). Foi empregada a análise confirmatória de fatores por meio dos modelos de equações estruturais A validade convergente do modelo fatorial foi avaliada pelas medidas de Average Variance Extracted (AVE), magnitude das cargas fatorias, alfa de Cronbach e confiabilidade composta. A validade discriminante do modelo fatorial foi avaliada pelas análises das cargas fatoriais cruzadas, comparação entre as raízes quadradas das AVEs, pelos coeficientes de correlação entre os construtos e pela correlação desatenuada. Os dados foram submetidos às análises descritivas, com avaliação da praticabilidade, aceitabilidade e efeitos teto e chão; de confiabilidade por meio do coeficiente alfa de Cronbach (consistência interna) e do coeficiente de correlação intraclasse (estabilidade da medida). O coeficiente de correlação de Spearman foi utilizado para testar a correlação entre os escores das versões brasileiras da SEAMS, MMAS-4e GSE. O teste de Mann-Whitney foi utilizado para verificar a capacidade da versão brasileira da SEAMS em discriminar entre coronariopatas classificados em "dose suficiente" ou "insuficiente" e entre aqueles "aderentes" e "não aderentes" ao tratamento medicamentoso. A versão traduzida da SEAMS apresentou evidências de equivalências semântico-idiomática, conceitual e cultural, com elevada aceitabilidade e praticabilidade. Foi evidenciado efeito chão para o escore total e domínios da SEAMS. Os achados evidenciaram confiabilidade da medida - coeficiente de correlação intraclasse (0,99) e coeficiente alfa de Cronbach (entre 0,85-0,90). Foram constatadas correlações significativas negativas de moderada a forte magnitude com os escores da MMAS-4, porém não foram encontradas correlações com os ecores da medida geral de autoeficácia. A validade de grupos conhecidos foi apoiada, uma vez que a escala discriminou entre aderentes e não aderentes ao tratamento medicamentoso. A análise fatorial confirmatória confirmou a estrutura de fatores do instrumento original. Os resultados evidenciaram cargas fatoriais cruzadas ? 0,50 para todos os itens da escala nos domínios em que foram alocados no instrumento original, AVE=0,52 para o fator 1 e 0,69 para o fator 2 e confiabilidade composta de 088 e 0,99 para os fatores 1 e 2, respectivamente, apontando para a validade convergente do modelo. Foram constatadas valores superiores de cargas fatoriais cruzadas para todos os itens da escala nos domínios em que foram previamente designados no instrumento original, raízes quadradas de AVEs superiores às correlações entre os construtos e correlação desatenuada (r=0,83), sugerindo validade discriminante do modelo. A confiabilidade de ambos os fatores, estimada de acordo com a homogeneidade dos itens, apontou para confiabilidade e validade de construto convergente da versão brasileira da SEAMS. Os achados apontam para confiabilidade e validade de construto da versão brasileira da SEAMS entre coronariopatas em seguimento ambulatorial / Abstract: This study aims to provide a version of the Self-efficacy for Appropriate Medication Adherence Scale - SEAMS for Brazilian culture and evaluate its measurement properties when applied to patients with coronary artery disease (CAD). The process of cultural adaptation was performed according to the steps proposed in the literature - translation, synthesis, back translation, expert committee review and pretesting, followed by evaluation of the feasibility, acceptability, reliability and validity. This study included 147 patients with CAD in the use of cardioprotective medications and relief of symptoms in outpatients at a university hospital in the state of São Paulo. Data were obtained by interview and instrument sociodemographic / clinical characterization and Brazilian versions of Morisky Self-Reported Measure of Medication Adherence Scale (MMAS-4), the General Perceived Self-Efficacy Scale (GSE) and SEAMS. Practicality was assessed by time spent in the interview and the acceptability by the proportion of patients who responded to all items of the instrument. Reliability with respect to the internal consistency and stability of the measurement was estimated. Construct validity was estimated by correlational evidence between the scores of the Brazilian version of SEAMS, the MMAS-4 and GSE. Known groups validity was tested between those classified as "sufficient dose" and "insufficient dose" (measure of the proportion of membership) and among those "adherent" and "nonadherent" (measure of overall assessment of compliance). Was used confirmatory factor analysis through structural equation models Convergent validity of the factorial model was evaluated by measurements of Average Variance Extracted (AVE), magnitude of loads fatorias, Cronbach's alpha and composite reliability. The discriminant validity of the model was evaluated by factorial analysis of cross-factor loadings, comparing the square roots of AVEs, the correlation coefficients between the constructs and the correlation desatenuada. Data were subjected to descriptive analyzes, assessing the feasibility, acceptability and ceiling and floor effects; reliability through Cronbach alpha (internal consistency) and the intraclass correlation coefficient (measurement stability). The Spearman correlation coefficient was used to test the correlation between the scores of the Brazilian versions of SEAMS, MMAS-4e GSE. The Mann-Whitney test was used to verify the ability of the Brazilian version of the SEAMS in discriminating between coronary classified as "adequate dose" or "insufficient" and among those "adherent" and "nonadherent" to drug treatment. The translated version of SEAMS presented evidence of idiomatic semantic-conceptual and cultural equivalence, with high acceptability and feasibility. Floor effect was evidenced for the total score and domains of SEAMS. The findings indicate reliability of the measure - the intraclass correlation coefficient (0.99) and Cronbach's alpha coefficient (between 0.85-0.90). Significant negative correlations of moderate to strong magnitude with the scores of MMAS-4 were observed, but no correlations with ecores general measure of self-efficacy were found. Known groups validity was supported, since the scale discriminated between adherent and non-adherent to medication treatment. Confirmatory factor analysis confirmed the factor structure of the original instrument. Results showed cross-factor loadings ? 0.50 for all items of the scale in areas that were allocated in the original instrument, AVE = 0.52 for factor 1 and 0.69 for factor 2 and composite reliability of 0.88 and 0.99 for factors 1 and 2, respectively, indicating the convergent validity of the model. Higher values of cross-factor loadings for all scale items in domains that were previously designated in the original instrument, the square roots of higher than the correlations between constructs and desatenuada correlation (r = 0.83) strokes were observed, suggesting discriminant validity of model. The reliability of both factors, estimated according to the homogeneity of the items pointed to reliability and convergent validity of the Brazilian version of the SEAMS. The findings point to reliability and construct validity of the Brazilian version of SEAMS between coronary outpatients / Mestrado / Enfermagem e Trabalho / Mestra em Ciências da Saúde

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/283880
Date07 July 2014
CreatorsSantos Pedrosa, Rafaela Batista dos, 1988-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Rodrigues, Roberta Cunha Matheus, 1965-, Rossi, Lídia Aparecida, Alexandre, Neusa Maria Costa
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Enfermagem, Programa de Pós-Graduação em Enfermagem
Source SetsIBICT Brazilian ETDs
LanguageMultilíngua, poreng
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format179 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds