Orientadores: João Jose Fagundes, Wu Feng Chung / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-05T16:39:13Z (GMT). No. of bitstreams: 1
Mochizuki_Miki_M.pdf: 2489617 bytes, checksum: 26c3c4feaf491a287f039a93363d25da (MD5)
Previous issue date: 2005 / Resumo: Aderências dirigidas são muitas vezes utilizadas como ¿reforço¿ de uma anastomose com o objetivo de diminuir o risco de deiscências. Neste trabalho analisou-se, por meio da aplicação dos testes Resistência à Pressão de Explosão e Resistência à Força de Tração, a resistência mecânica de anastomoses realizadas em cólon isquêmico com e sem utilização de aderências dirigidas. Quarenta ratos foram distribuídos igualmente em dois grupos. O Grupo 1 era constituído de vinte animais em que as anastomoses cólicas isquêmicas foram recobertas por uma película de polivinilcloreto (P.V.C.) para impedir a formação de aderências sobre as linhas de sutura e o Grupo 2 era constituído por 20 animais em que as anastomoses cólicas isquêmicas foram recobertas pela gordura epididimal, de forma a constituir uma aderência dirigida sobre a linha de sutura, sendo ainda recobertas por uma película de P.V.C. para impedir a formação de outras aderências. Resultados: A média da Pressão de Ruptura à Distensão por Líquidos da anastomose foi de 10 mmHg no grupo sem aderência e de 55,2 mmHg no grupo com aderência (p < 0,05). A média da Força de Ruptura à Tração das anastomoses foi de 142,5 gf no grupo sem aderências e de 262 gf no grupo com aderência (p < 0,05). Por meio dos ensaios mecânicos, as aderências demonstraram ser benéficas, elevando a resistência intrínseca das anastomoses em cólon isquêmico / Abstract: Adhesions are many times used as a 'reinforcement¿ of anastomoses in order to minor the risk of dehiscence. In this work the mechanical parameters Bursting Strength Test and Breaking Strength Test were tested in order to evaluate the mechanical resistance of ischemic colon anastomoses in 40 rats, which were divided into groups with and without adhesions. Forty rats were divided into two groups. Group 1 was composed of 20 rats in which the anastomoses were covered with P.V.C. (Polyvinyl Chloride) to prevent the occurrence of adhesions over the anastomotic line. Group 2 was composed of 20 rats in which anastomotic line was covered with epididimal fat besides P.V.C. to prevent formation of other adhesions. The mean Bursting Strength of the anastomoses in the group without adhesion was 10 mmHg and this value was 55.2 mmHg in the group with adhesion (p < 0.05). The mean Breaking Strength of the anastomoses was 142.5 gf in the group without adhesion and 262 gf in the group with adhesion (p < 0.05). Based on those mechanical tests, adhesions were benefic to ischemic anastomoses, raising their intrinsic resistence. both on Bursting and Breaking Strength / Mestrado / Cirurgia / Mestre em Cirurgia
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/312421 |
Date | 28 September 2005 |
Creators | Mochizuki, Miki |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Wu, Feng Chung, Fagundes, João Jose, 1943-, Netinho, João Gomes, Coy, Claudio Saddy Rodrigues |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 90p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0021 seconds