Return to search

Avaliação de parametros cardiovasculares pre, trans e pos anestesia local em pacientes normotensos

Orientador: Jose Ranali / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-01T00:20:44Z (GMT). No. of bitstreams: 1
Soares_PatriciaCristinedeOliveira_M.pdf: 3581523 bytes, checksum: 0acfec963e5a1be1e2748b5f7426b0e7 (MD5)
Previous issue date: 2002 / Resumo: Este estudo avaliou a variação de parâmetros cardiovasculares após injeção anestésica, através do monitoramento contínuo por 48 horas. Foram selecionados 20 voluntários com idade entre 20 e 39 anos, normotensos, saudáveis e com canino superior direito hígido. Realizaram-se registros da pressão arterial sistólica (PAS), diastólica (PAD), média (PAM) e freqüência cardíaca (FC) em 3 fases: A - monitoramento por 24 horas sem procedimento odontológico; B pnmeIro procedimento anestésico, 48 horas, registros 15-15 minutos, e 2-2 minutos durante o procedimento anestésico; o segundo procedimento anestésico, semelhante a fase B, variando a solução anestésica. As injeções infiltrativas, vestibular e palatina, foram realizadas com duas soluções anestésicas: articaína 4% com adrenalina 1: 100.000 (Septanest® - DFL) e lidocaína 2% com adrenalina 1:100.000 (Alphacaine® - DFL), nas sessões B e C, de forma cruzada, duplo-cega e ao acaso. A eficiência da anestesia foi analisada pela aplicação de estímulo elétrico, e a sensibilidade dolorosa pela escala analógica visual. A análise de variância em esquema de parcelas subdivididas ('alfa¿= 0,05) foi utilizada para avaliar as variações nos parâmetros cardiovasculares e mostrou não haver diferença estatística significante entre as 3 fases. Ao analisar os valores obtidos nas 48 horas, observaram-se que houve diferenças estatísticas nos sub-períodos para PAS, PAD, PAM e FC (p< 0,0001). Durante o procedimento anestésico observou-se diferenças estatísticas significantes em relação aos subperíodos, porém com diminuição frente aos outros intervalos de avaliação. Os valores comparativos entre as soluções anestésicas foram analisados pelo teste de Wilcoxon pareado ('alfa¿= 0,05), não havendo diferença estatística significante entre as soluções de articaína e lidocaína quanto a latência (p=0,80), anestesia completa (p= 0,08), parcial (p= 0,55) e em tecidos moles (p= 0,18). Os valores da Escala Analógica Visual foram submetidos ao teste de Wilcoxon pareado ('alfa¿= 0,05), não foram verificadas diferenças entre as duas soluções (p=0,45). Pode-se concluir que em pacientes jovens, normotensos e saudáveis, o procedimento anestésico e a sensibilidade dolorosa não provocaram aumento dos parâmetros cardiovasculares avaliados e que as soluções anestésicas apresentaram desempenho clínico similares / Abstract: The purpose of this study was to evaluate the changes ofcardiovascular parameters by anesthetic injection, throughout a 48-hour continuous nonlnvaslve registration. Twenty normotensive healthy volunteers, aged between 20-39 years, were selected. The heart rate (HR) and systolic (SBP), diastolic (DBP) and media (MBP) blood pressures were evaluated in 3 phases: A - registration for 24 hours without anesthetic injection; B - first anesthetic solution injection, registration for 48 hours, the records were taken every 15 minutes, and every 2 minutes during the anesthetic procedure; C ¿ second anesthetic solution, similar to phase B. The infiltration anesthesias with the solutions in the vestibular and palatine regions of upper right canine were accomplished using two anesthetic solutions: articaine 4% with adrenaline 1:100.000 (Septanest-DFL) and lidocaine 2% with adrenaline 1:100.000 (Alphacaine-DFL), in a double blind cross-over manner. The efficiency of the anesthesia was verified by application of electric stimulus and the painful sensibility was verified by the visual analogue scale. The cardiovasculars parameters were analyzed trought ANOVA in sub-parcels scheme following Tukey's test ('alfa¿=0,05). No statistical significant difference was observed among the 3 phases. When the values obtained in 48 hours were analyzed, statistical differences were observed in the sub-periods of 48 hours period in SBP, DBP, MBP and HR (p< 0,0001) and in sub-periods during the anesthetic procedure with decrease in cardiovascular parameters during this procedure. The comparative values between two anesthetic solutions were analyzed by Wilcoxon's test ('alfa¿=0,05). There were no significant statistical differences between articaine and lidocaine solutions by latency (p= 0,80) and pulp (p= 0,08), partial (p= 0,55) and soft tissue (p= 0,18) anesthesias. For visual analogue scale the two solutions did not present differences (p=0,45). It can be concluded that in normotensive healthy patients, the anesthetic injection and painful sensibility were not enough to increase the cardiovasculars parameters, and the both anesthetic solutions, lidocaine 2% with adrenaline 1:100.000 and articaine 4% with adrenaline 1: 100.000, presented similar clinical behavior / Mestrado / Farmacologia, Anestesiologia e Terapeutica / Mestre em Odontologia

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289397
Date18 February 2002
CreatorsSoares, Patricia Cristine de Oliveira
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Ranali, José, 1949-, Barbosa, Darceny Zanetta, Volpato, Maria Cristina
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Odontologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format143p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0027 seconds