Return to search

Correlação entre ansiedade e dor com a pressão arterial e a frequencia cardiaca durante o atendimento odontologico de urgencias

Orientador: Jose Ranali / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T21:52:16Z (GMT). No. of bitstreams: 1
Rodrigues_RodrigoVentura_M.pdf: 301241 bytes, checksum: d514c81d282fc431e00d567e0748f4ce (MD5)
Previous issue date: 2004 / Resumo: Este trabalho avaliou a influência da dor e da ansiedade sobre a pressão arterial de pacientes que compareceram no Plantão de Urgências da Faculdade de Odontologia de Piracicaba/UNICAMP. Foram selecionados, de forma aleatória, 139 voluntários. Características populacionais como gênero, idade e nível cultural também foram avaliados. Enquanto aguardavam na sala de espera, os voluntários foram submetidos à Escala de Ansiedade Odontológica de Corah (EAO). Além disso, para avaliar a dor com que os voluntários chegavam ao plantão de urgências, foi aplicada uma Escala Analógica Visual (EAV) antes do atendimento. A pressão arterial (PA) e a freqüência cardíaca (FC) foram avaliadas em 5 momentos distintos: a) a inicial, com o paciente na sala de espera; b) na cadeira odontológica, porém antes do atendimento; c) logo após a aplicação do anestésico local; d) dez minutos após a aplicação do anestésico local; e) ao término do atendimento. Todas as coletas de dados e aferições da PA e da FC foram realizadas por um único avaliador, o qual não teve nenhuma participação no atendimento odontológico realizado pelos alunos de graduação. Todos os dados foram submetidos ao teste de Kruskal-Wallis, Friedman ou Mann-Whitney. Os resultados revelaram que a ansiedade e a dor não foram afetadas pela idade, entretanto a primeira foi relacionada ao gênero (p<0,05). O nível de atenção ao paciente não foi influenciado pelo grau de ansiedade que o mesmo apresentava (p>0,05). Além disso, foi observada relação entre relatar a dor, exibir ansiedade e demonstrar dor com o nível de ansiedade. Entretanto, o nível de ansiedade exibido pelo paciente não foi levado em consideração para a adoção de medidas de controle da mesma. Embora os anestésicos locais contendo adrenalina tenham sido os mais utilizados para técnicas anestésicas, a prática da aspiração não foi comum (p<0,05). Os parâmetros cardiovasculares avaliados no decorrer do atendimento odontológico não foram afetados pelo grau de ansiedade e dor, medidos previamente à sessão (p>0,05) / Abstract: The purpose of this study was to evaluate the influence of pain and anxiety over the blood pressure of patients during emergency situations, whose were attended in the Dental Emergency Service of Piracicaba Dental School. One hundred and thirty nine volunteers were selected. Populational factors like gender, age and instruction degree were verified. During waiting for the treatment, these patients were submitted to the Anxiety¿s Dental Scale of Corah in order to establish the degree of anxiety and to a Visual Analogue Scale to evaluate the pain degree before the dental treatment. The blood pressure and cardiac frequency (CF) were evaluated at five different moments: a) first: patient at the waiting room; b) at the dental chair (before the treatment); c) after the local anesthesia; d) ten minutes after anesthesia; and e) at the end of the treatment. Also, the execution of aspiration prior anesthesia, the kind of anesthesia and the anesthetic used were evaluated. All measurements were performed by the same examiner, which did not execute any dental procedure. The data were submitted to Kruskal-Wallis, Friedman or Mann-Whitney tests. The results showed that the anxiety and pain were not affected by age, but anxiety is affected by the patient¿s gender (p<0.05). The anxious patients did not receive more attention from the operator than the non anxious ones (p>0.05). Also, it was not observed relationship between anxiety degree (Corah scale) and pain or anxiety related by patients. The anxiety degree was not considered by the operator in order to adopt anxiety control procedures. The local anesthetics with epinephrine and blocking injections were the most used, but aspiration was not usual (p<0.05). The cardiovascular parameters (CF and blood pressure) were not affected by the initial anxiety and pain degrees (p>0.05) / Mestrado / Farmacologia, Anestesiologia e Terapeutica / Mestre em Odontologia

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289398
Date30 January 2004
CreatorsRodrigues, Rodrigo Ventura
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Ranali, José, 1949-, Groppo, Francisco Carlos, Mattos Filho, Thales Rocha de, Rocha, Rodney Garcia
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format68f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0029 seconds