Orientador: Luis Guillermo Bahamondes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-07T00:15:39Z (GMT). No. of bitstreams: 1
Dantas_MariaCeciliaMonteiro_M.pdf: 1386064 bytes, checksum: 40ec263d571f513e5156a0dee8685dd4 (MD5)
Previous issue date: 2006 / Resumo: O objetivo do estudo foi avaliar e comparar a densidade mineral óssea (DMO) em mulheres aos 18 meses de uso de implantes contraceptivos liberadores de etonogestrel ou levonorgestrel. Foram admitidas 111 mulheres, de 19 a 43 anos de idade, sendo 56 usuárias do implante liberador de etonogestrel (Implanon®) e 55 mulheres usuárias do implante liberador de levonorgestrel (Jadelle®). A DMO foi avaliada nas porções distal e ultradistal do rádio do antebraço não dominante, usando-se a técnica de absorciometria dupla (DXA), antes da inserção e aos 18 meses de uso. Não houve diferença nas características demográficas ou antropométricas, ou na DMO previamente à inserção de ambos os modelos de implantes. A DMO foi significativamente menor aos 18 meses de uso na região distal do rádio nos dois grupos de usuárias. Entretanto, não houve diferença na região ultradistal. A análise por regressão linear múltipla mostrou que as variáveis associadas com a diminuição da DMO aos 18 meses de uso em ambos os grupos de implantes foram a DMO inicial, índice de massa corporal (IMC) e diferença no IMC (zero versus 18 meses de uso). Mulheres de 19 a 43 anos de idade, usando um ou outro implante, tiveram significativamente menor DMO aos 18 meses de uso na região distal; entretanto sem diferença na região ultradistal do rádio, quando comparada com os valores obtidos antes da inserção / Abstract: The objetive of this study was to compare bone mineral density (BMD) before insertion and at 18 months of use of etonogestrel (Implanon®) and levonorgestrel-releasing (Jadelle®) contraceptive implants. One-hundred eleven women, 19-43 years of age, were randomly allocated to 2 groups: 56 to Implanon and 55 to Jadelle. BMD was evaluated at the midshaft of the ulna and at the distal radius of the non-dominant forearm using dual energy X-ray absorptiometry before insertion and at 18 months of use. There was no difference in baseline demographic or anthropometric characteristics, or in BMD of users of either model of implant. BMD was significantly lower at 18 months of use at the midshaft of the ulna in both groups of users. However, no difference was found at the distal radius. Multiple linear regression analysis showed that the variables associated with BMD at 18 months of use in both implant groups were baseline BMD and body mass index (BMI) and difference in BMI (O versus 18 months of use). Women of 19-43 years of age using either one of the implants showed lower BMD at 18 months of use at the midshaft of the ulna, however, without a difference at the distal radius / Mestrado / Ciencias Biomedicas / Mestre em Tocoginecologia
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/313043 |
Date | 28 July 2006 |
Creators | Dantas, Maria Cecilia Monteiro |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Bahamondes, Luis Guillermo, 1946- |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Tocoginecologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 49f., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0084 seconds