Return to search

Caracterização do desempenho de compressores de refrigeração segundo um ciclo superaquecido de teste

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2007. / Submitted by Luanna Maia (luanna@bce.unb.br) on 2009-03-06T14:13:05Z
No. of bitstreams: 1
Dissertacao_ Leandro Joffily.pdf: 5652934 bytes, checksum: e670dfb33127ebf7c93edb9d4820b48c (MD5) / Approved for entry into archive by Luanna Maia(luanna@bce.unb.br) on 2009-03-06T16:08:42Z (GMT) No. of bitstreams: 1
Dissertacao_ Leandro Joffily.pdf: 5652934 bytes, checksum: e670dfb33127ebf7c93edb9d4820b48c (MD5) / Made available in DSpace on 2009-03-06T16:08:42Z (GMT). No. of bitstreams: 1
Dissertacao_ Leandro Joffily.pdf: 5652934 bytes, checksum: e670dfb33127ebf7c93edb9d4820b48c (MD5) / O presente trabalho tem como finalidade a avaliação de uma metodologia de testes de
caracterização de desempenho de compressores, de ar condicionado e refrigeradores. Essa
metodologia visa reduzir o tempo para a realização de testes de desempenho e reduzir o
consumo de energia para esse mesmo fim. Para a consolidação dessa metodologia, foi
construída uma bancada didática e utilizado um modelo computacional, a fim de obter
resultados que validem os obtidos aqueles experimentais.
A bancada de testes tem configuração física diferente dos ciclos de compressão a vapor. Na
bancada, o refrigerante é trabalhado apenas na região de vapor superaquecido. Para alcançar
esse objetivo, a bancada é composta por um compressor seguido de um dispositivo de
expansão e, posteriormente, um trocador de calor responsável pelo dessuperaquecimento do
refrigerante. Uma segunda opção de montagem da bancada é a troca de posição entre o
dispositivo de expansão e o trocador de calor, dessa forma o dessuperaquecimento do
refrigerante é feito antes de sua expansão. Finalmente, a utilização da combinação entre a
primeira e a segunda opção de montagem pode ser utilizada. Nesse caso, o refrigerante sofrerá
um pequeno dessuperaquecimento seguido de uma expansão, voltando a ser dessuperaquecido
após o dispositivo de expansão. Essa gama de opções é utilizada com a finalidade de ampliar
a faixa de testes, já que cada configuração apresenta uma limitação específica. Para um
refinamento ainda maior dos resultados uma câmara calorimétrica é montada ao redor do
compressor.
Os ensaios realizados na bancada mostraram que a metodologia apresenta resultados
satisfatórios. A operação da bancada é simples e eficiente, fato comprovado pelos 85% dos
ensaios realizados estarem dentro da faixa de operação do compressor e esses ensaios
cobrirem 55% da área de operação do mesmo. A agilidade de alterações de condições de
ensaio é notória, pois o tempo médio de alteração de condições de operação foi de 30
minutos. Além disso, os resultados aproximaram-se dos dados indicados no catálogo do
compressor testado.
___________________________________________________________________
ABSTRACT / The concern with the energy crisis worldwide, which is assessed a methodology for the
characterization tests the performance of compressors, air conditioners and refrigerators. This
approach aims to reduce the time for the testing of performance and reduce the consumption
of energy to the same end. To consolidate this methodology, was built a didactic workbench,
along with a computational model in order to obtain results that validate those obtained
experimentally.
The bench tests have different physical configuration of the steam cycles of compression. At
the workbench, the refrigerant is working only in the region of steam overheated. To achieve
this goal, the workbench is composed of a compressor followed by a device for expansion
and, subsequently, a heat exchanger unoverheated responsible for the coolant. A second
option for assembly of the stand is the exchange of position between the device and the
expansion of the heat exchanger, so the unoverheated the coolant is done before its expansion.
Finally, the use of the combination between the first and the second option of mounting can
be used, so the coolant will suffer a small unoverheated followed by an expansion, returning
to unoverheated after the device for expansion. This range of options is used for the purpose
of broadening the range of tests, as each configuration provides a specific limitation. For an
even greater refinement of the results calorimetric chamber mounted around the compressor.
Tests conducted in workbench showed that the methodology gives satisfactory results. The
operation of the stand is simple and efficient. This fact is evidenced by the 85% of the tests
were within the range of operation of the compressor and these tests cover 55% of the area of
operation of the same. The speed of change of a test is notorious because the average time for
changes to conditions of operation was 30 minutes. In addition, the results are closer to the
data listed in the catalog of compressor tested.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/1452
Date10 1900
CreatorsJoffily, Leandro de Azevedo Lima
ContributorsPimenta, João Manoel Dias
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds