Return to search

Analise do movimento de abdução do ombro : comparação entre dois metodos de avaliação / Analysis of shoulder movement

Orientador: Alberto Cliquet Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-05T01:05:19Z (GMT). No. of bitstreams: 1
Sonego_DeniseAparecida_M.pdf: 6116885 bytes, checksum: e05be11ecadbb546cf9fad2e9270e754 (MD5)
Previous issue date: 2005 / Resumo: Sistemas ópticos de captura dos movimento são recursos de medição para analisar o movimento articular. A proposta deste estudo foi de (1) comparar o sistema óptico de captura do movimento, com o goniômetro universal (em duas posições de medida: com os braços do goniômetro fechado e aberto) verificando a concordância intra e interexaxaminadores no movimento de abdução do ombro em indivíduos saudáveis e (2) verificar a aplicação do sistema óptico Qualisys, comparando casos patológicos com indivíduos normais. Dezessete indivíduos saudáveis foram avaliados. A análise do movimento foi instituída, utilizando o programa ¿Qview¿, e os dados exportados para o programa ¿Qtools 2.0¿ Três câmaras de vídeo com amostragem de 60 Hz foram utilizadas. Marcadores reflexíveis foram colocados em estruturas anatômicas, para a obtenção das coordenadas tridimensionais. Para verificar a concordância intra e interexaminadores no mesmo método, utilizou-se o coeficiente de correlação linear de Person, considerando (p < 0,05). Os resultados obtidos para o sistema de captura de movimento interexaminadores foram moderados (r>0,62). Para intra-examinadores, o coeficiente foi estatisticamente significante (r>0.92). Para verificar a aplicação do sistema óptico Qualisys, foi utilizado o teste de Mann-Whitney demonstrando as diferenças nos movimentos e amplitudes articulares entre ombros patológicos e normais / Abstract: Optical systems of motion capture are powerful resources of measurement to analyse the articular movement. The purpose of this study was (10 to compare the optical systems of motion capture with the universal goniometer used in two measurements; with the goniometer arms closed and opened; and to assess the agreement of intra and interexaminers in the shoulder¿s abduction movement in healthy individuals and (2) to verify the application of the Qualiys¿s optical system towards comparing pathological and healthy individual. Seventeen healthy individuals were evaluated. The movement analusis was done using ¿Qviews¿ software, the data exported to ¿Qtools 2.0¿ software. Three video cameras at 60 Hz sampling frequency were used. Reflexive marks were placed in anatomical structures, to obtain the three-dimensional coordinates. Person¿s linear correlation (p< 0.05) was used towards verifying agreement for intra and interexaminers. The interexaminers results were moderate (r>0,62). To intraexaminers result in the same method, was statistically significant (r> 0,92). Mann-Whitney test was used to verify the application of the Qualisys¿ optical system, demonstrating the differences in the movement and joint amplitudes both in pathological and normal shoulders / Mestrado / Pesquisa Experimental / Mestre em Cirurgia

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/313757
Date21 June 2005
CreatorsSonego, Denise Aparecida
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Cliquet Junior, Alberto, 1957-, Piedade, Sérgio Rocha, Assis, Silvana Maria Blascovi de
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Cirurgia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format155 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds