Estudo comparativo de m?todos de extra??o para determina??o de fluazuron em plasma bovino por cromatografia l?quida de alta efici?ncia com detec??o em ultravioleta. / Comparison of extraction methods for determining fluazuron in bovine plasma by high-performance liquid chromatography with UV detection.

Submitted by Leticia Schettini (leticia@ufrrj.br) on 2016-10-04T13:00:01Z
No. of bitstreams: 1
2016 - Thais Paes Ferreira.pdf: 1131707 bytes, checksum: c98267296d6293f703188fe1291622db (MD5) / Made available in DSpace on 2016-10-04T13:00:01Z (GMT). No. of bitstreams: 1
2016 - Thais Paes Ferreira.pdf: 1131707 bytes, checksum: c98267296d6293f703188fe1291622db (MD5)
Previous issue date: 2016-05-11 / Fluazuron is a benzoylphenylurea acarine growth inhibitor that is marketed for the control
of cattle tick. Although the growth regulators are widely studied class, the number of papers
describing analytical methods for determining the fluazuron in plasma samples is reduced.
The development of a simple and fast analytical method for quantifying fluazuron in bovine
plasma by HPLC-UV enables the evaluation of drug plasma profile and can be applied on
bioavailability analysis of formulations containing fluazuron. In recent years there has been
a technological breakthrough for chromatographic instrumentation, providing rapid, robust
and sensitive methods, but the pretreatment of the sample stage becomes the limiting factor
in this process. New extraction methods have been developed, however are often complex,
expensive methods and are not as sophisticated to handle complex matrices, such as plasma.
The aim of this study was a comparative study of three extraction methods: LLE, SPE and
matrix solid phase dispersion (MSPD). Pooled plasma samples were used as biological
material, partly as raw samples and partly spiked with concentrations of fluazuron. For each
extraction method (with exception of DMFS) was conducted using various solvents (ethyl
acetate, dichloromethane, diethyl ether, hexane and acetonitrile) in order to evaluate the best
extractor solvent. After the extractions the samples were concentrated and analyzed by
HPLC/UV. The chromatographic separation was achieved on Kromasil C18 column
preceded by guard column of matching chemistry, with mobile phase of acetonitrile: water
(80:20, v/v) at flow rate of 1.0 mL/min. The comparative analysis of the extraction
procedures was based on selectivity, precision and accuracy of the method. Results showed
that LLE not presented accuracy (< 80 and >120%) and precision (CV > 15%) with any
solvent tested. SPE method showed good accuracy (80-120%) and precision (CV < 15%)
for ethyl acetate, dichloromethane and diethyl ether. MSPD method using ethyl acetate
solvent showed good accuracy and precision. However, SPE also allows a lower solvent
consumption and shorter analysis time. The validation of the analytical method showed
linearity, selectivity, precision, accuracy and, absence matrix effects and residual, thus
proving it as suitable for routine analysis; This method showed to be an important
investigative tool in the analysis of fluazuron plasma concentration in cattle. Fluazuron
topical administration in bovine reached the systemic circulation (Cmax=62,8 ng/mL), was
absorbed (tmax=48 hs), while maintaining quantifiable blood plasma levels for up to 14 days
after the treatment with a 2,5 mg/Kg dosage. / Fluazuron ? um inibidor do crescimento da classebenzoilfenilur?ia, sendo comercializado
para o controle de carrapatos do gado. Embora a classe de reguladores de crescimento sejam
amplamente estudada, o n?mero de artigos que descrevem os m?todos anal?ticos para a
determina??o do fluazurom em amostras de plasma ? escasso. O desenvolvimento de um
m?todo anal?tico simples e r?pido para quantificar fluazuron em plasma bovino por CLAEUV
permite a avalia??o do perfil plasm?tico do f?rmaco e pode ser aplicado na an?lise de
biodisponibilidade de formula??es contendo fluazurom. Nos ?ltimos anos, tem acontecido
um avan?o tecnol?gico para a instrumenta??o cromatogr?fica, proporcionando m?todos
r?pidos, eficazes e sens?veis, mas a etapa de pr?-tratamento da amostra torna-se o fator
limitante neste processo. Novos m?todos de extra??o t?m sido desenvolvidos, no entanto,
muitas das vezes s?om?todos complexos, caros e n?o t?o sofisticados para matrizes
complexas como o plasma. O objetivo deste estudo foi um estudo comparativo de tr?s
m?todos de extra??o: extra??o l?quido-l?quido (ELL), extra??o em fase s?lida (EFS) e
dispers?o de matriz em fase s?lida (DMFS). Ums mistura de amostras de plasma foi
utilizada como material biol?gico, uma parte como amostra bruta e outra parcialmente
enriquecida com concentra??es de fluazuron. Para cada m?todo de extra??o (exceto DMFS)
foram analisadosdiversos solventes (acetato de etila, diclorometano, ?ter diet?lico, hexano
e acetonitrila), a fim de avaliar o melhor solvente extrator. Ap?s as extra??es, as amostras
foram concentradas e analisadas por CLAE/UV. A separa??o cromatogr?f ica foi obtida na
coluna Kromasil C18 precedida de pr?-coluna de fase qu?mica correspondente, com fase
m?vel de acetonitrila: ?gua (80:20, v/v) a um fluxo de 1,0 mL /min. A an?lise comparativa
dos procedimentos de extra??o foi baseada na seletividade, precis?o e exatid?o do m?todo.
Os resultados mostraram que a precis?o ELL n?o apresentou exatid?o (<80 e> 120%) e
precis?o (CV> 15%) com nenhum dos solventes analisados. O m?todo EFS mostrou boa
exatid?o (80-120%) e precis?o (CV <15%) para o acetato de etila, diclorometano e ?ter
diet?lico. O m?todo de DMFS utilizando o solvente acetato de etila mostrou boa exatid?o e
precis?o. No entanto, a EFS tamb?m permite um menor consumo de solventes e um tempo
curto de an?lise; A valida??o do m?todo anal?tico mostrou linearidade, seletividade,
precis?o, exatid?o e, aus?ncia de efeitos de matriz e residual, demonstrando-se adequado
para an?lises de rotina; Este m?todo mostrou-se uma ferramenta de investiga??o importante
na an?lise de concentra?? plasm?tica em bovinos. Fluazuron administrado por via t?pica
em bovinos atingiu a circula??o sist?mica (Cmax = 62,8 ng /ml) e foi absorvido (Tm?x =
48 Hs), se mantendo quantificav?l em n?veis plasm?ticos por at? 14 dias ap?s o tratamento
com uma dosagem de 2,5 mg / kg.

Identiferoai:union.ndltd.org:IBICT/oai:localhost:jspui/1229
Date11 May 2016
CreatorsFerreira, Thais Paes
ContributorsCid, Yara Peluso, Padilha, Monica Costa, Almeida, Vanessa Gomes Kelly
PublisherUniversidade Federal Rural do Rio de Janeiro, Programa de P?s-Gradua??o em Qu?mica, UFRRJ, Brasil, Instituto de Ci?ncias Exatas
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UFRRJ, instname:Universidade Federal Rural do Rio de Janeiro, instacron:UFRRJ
Rightsinfo:eu-repo/semantics/openAccess
RelationAHMADI-JOUIBARI, T. et al. Dispersive liquid?liquid microextraction followed by highperformance liquid chromatography?ultraviolet detection to determination of opium alkaloids in human plasma. Journal of Pharmaceutical and Biomedical Analysis, v. 85, p. 14?20, 2013. ANVISA. Manual de boas pr?ticas em biodisponibilidade e bioequivalencia. 1. ed. Bras?lia: ANVISA, 2002. ANVISA. Ag?ncia Nacional de Vigil?ncia Sanit?ria. Resolu??o RE n 899, 29 de maio de 2003, p. 1?15, 2003. ANVISA. Ag?ncia Nacional de Vigil?ncia Sanit?ria. Resolu??o RDC no 27 de 17 de maio de 2012, p. 1?12, 2012. ARMISHAW, P.; WARD, J.; MILLAR, R. G. Development of a reference material for residues of chlorfluazuron and fluazuron in beef fat ACSL CRM 3. Fresenius Journal of Analytical Chemistry, v. 356, n. 1, p. 13?16, 1996. AZODI-DEILAMI, S. et al. Magnetic molecularly imprinted polymer nanoparticles for the solid-phase extraction of paracetamol from plasma samples, followed its determination by HPLC. Microchimica Acta, v. 181, n. 15-16, p. 1823?1832, 2014. BACK, H. et al. A novel HPLC-MS/MS method for the simultaneous determination of astemizole and its major metabolite in dog or monkey plasma and application to pharmacokinetics. Journal of pharmaceutical and biomedical analysis, v. 114, p. 121?6, 2015. BALB?O, M. S. et al. Rifampicin determination in plasma by stir bar-sorptive extraction and liquid chromatography. Journal of Pharmaceutical and Biomedical Analysis, v. 51, n. 5, p. 1078?1083, 2010. BALDELLI, S. et al. Comparison of the QMS? analyzer with HPLC-UV for the quantification of lamotrigine concentrations in human plasma samples. Therapeutic Drug Monitoring, v. 37, n. 5, p. 1, 2015. BARKER, S. A. Matrix solid phase dispersion (MSPD). Journal of Biochemical and Biophysical Methods, v. 70, n. 2, p. 151?162, 2007. BORGES, K. B.; FIGUEIREDO, E. C. DE; QUEIROZ, M. E. C. Preparo de amostras para an?lise de compostos org?nicos. Rio de Janeiro: LTC, 2015. BUENO, M. M. Implanta??o , evolu??o , aspectos t?cnicos e perspectivas da regulamenta??o t?cnica de biodisponibilidade relativa e bioequival?ncia de medicamentos gen?ricos e similares no Brasil. [s.l.] Disserta??o de Mestrado,Faculdade de Ci?ncias Farmac?uticas,Universidade de S?o Paulo, 2005. BUSZEWSKI, B.; SZULTKA, M. Past, Present, and Future of Solid Phase Extraction: A Review. Critical Reviews in Analytical Chemistry, v. 42, n. 3, p. 198?213, 2012. BYLDA, C. et al. Recent advances in sample preparation techniques to overcome difficulties encountered during quantitative analysis of small molecules from biofluids using LC-MS/MS. The Analyst, v. 139, p. 2265?76, 2014. CALDAS, S. S. et al. Modern techniques of sample preparation for pesticide residues determination in water by liquid chromatography with detection by diode array and mass spectrometry. Quimica Nova, v. 34, n. 9, p. 1604?1617, 2011. CAMPOS, C. D. M. et al. Preparo de amostras assistido por campo el?trico:Fundamentos,Avan?oes,Aplica??e e Tend?ncias. Quimica Nova, v. 38, n. 8, p. 1093? 1106, 2015. CAPRIOTTI, A. et al. Recent Developments in matrix solid phase dispersion extraction. Journal of Chromatography A, v. 1217, p. 2521?2532, 2010. CAPRIOTTI, A. L. et al. Recent trends in matrix solid-phase dispersion. TrAC - Trends in Analytical Chemistry, v. 43, p. 53?66, 2013. CASSIANO, N. M. et al. Valida??o em m?todos cromatogr?ficos para an?lises de pequenas mol?culas em matrizes biol?gicas. Quimica Nova, v. 32, n. 4, p. 1021?1030, 2009. CHAVES, A. R. et al. The development of a new disposable pipette extraction phase based on polyaniline composites for the determination of levels of antidepressants in plasma samples. Journal of Chromatography A, v. 1399, p. 1?7, 2015. CHEN, L. et al. Study on the simultaneous determination of seven benzoylurea pesticides in Oolong tea and their leaching characteristics during infusing process by HPLC-MS/MS. Food Chemistry, v. 143, p. 405?410, 2014. CID, Y. P. et al. Determination of fipronil in bovine plasma by solid-phase extraction and liquidchromatography with ultraviolet detection. Qu?mica Nova, v. 35, n. 10, p. 2063?2066, 2012. DE OLIVEIRA, A. R. M. et al. Microextra??o em fase l?quida (LPME): Fundamentos da t?cnica e aplica??es na an?lise de f?rmacos em fluidos biol?gicos. Quimica Nova, v. 31, n. 3, p. 637?644, 2008. DE OLIVEIRA, P. R. et al. Potential of the insect growth regulator, fluazuron, in the control of Rhipicephalus sanguineus nymphs (Latreille, 1806) (Acari: Ixodidae): Determination of the LD 95 and LD 50. Experimental Parasitology, v. 131, n. 1, p. 35?39, 2012. EMEA - EUROPEAN MEDICINES AGENCY. EMEA/CVMP/77290/05Committee for Medicinal Products for Veterinary Use: Fluazuron. Londres: [s.n.]. Dispon?vel em: <http://www.emea.europa.eu/>. Acesso em: 20 jan. 2016. FAEZEH, KHALILIAN AND MOHAMMAD, R. Extraction and determination of Organosulfur Compounds in water samples by using homogeneous liquid-liquid microextraction via flotation assistance-gas chromatography-flame ionization detection. Bull.Chem.Soc.Ethiop, v. 28, n. 2, p. 195?204, 2014. FARHADI, K.; FIRUZI, M.; HATAMI, M. Stir bar sorptive extraction of propranolol from plasma samples using a steel pin coated with a polyaniline and multiwall carbon nanotube composite. Microchimica Acta, v. 182, n. 1-2, p. 323?330, 2015. FERN?NDEZ, P. et al. A rapid ultrasound-assisted dispersive liquid?liquid microextraction followed by ultra-performance liquid chromatography for the simultaneous determination of seven benzodiazepines in human plasma samples. Analytica Chimica Acta, v. 767, p. 88?96, 2013. FSCJ - FOOD SAFETY COMISION OF JAPAN. Risk assessment report Fluazuron ? veterinary medicinal productsFS/732/2015Food Safety Commission of Japan Report. [s.l: s.n.]. Dispon?vel em: <http://www.fsc.go.jp/english/evaluationreports/vetmedicine/fluazuron_fs732_2015.pdf>. HUI-YING, D. et al. Determination of 11 Benzoylurea Insecticides Residues in Vegetable by LC-MS/MS. Journal of Instrumental Analysis, n. 08, 2009. JARDIM, I. C. S. F. Extra??o em Fase S?lida : Fundamentos Te?ricos e Novas Estrat?gias para Prepara??o de Fases S?lidas. Scientia Chromatographica, v. 2, n. 1, p. 13?25, 2010. KOLLIPARA, S. et al. International guidelines for bioanalytical method validation: A comparison and discussion on current scenario. Chromatographia, v. 73, n. 3-4, p. 201?217, 2011. KUMAR, A. et al. Development and validation of an RP-HPLC method for the quantitation of odanacatib in rat plasma and its application to a pharmacokinetic study. Biomedical Chromatography, v. 27, n. 12, p. 1590?1594, 2013. KUMAR, S.; LATHER, V.; PANDITA, D. Stability indicating simplified HPLC method for simultaneous analysis of resveratrol and quercetin in nanoparticles and human plasma. Food Chemistry, v. 197, p. 959?964, 2016. LAN?AS, F. M. Extra??o em fase s?lida (SPE). 1. ed. S?o Carlos: RiMa Editora, 2004. LCGC. Overview of Sample Preparation. LCGC:Liquid Chromatgraphy, Gas Chromatography North America, v. 33, n. Special, p. 1?7, 2015. LEITE, F. Valida??o em an?lise qu?mica. 5a. ed. Campinas: Editora ?tomo, 2008. LUXINLUN. Study on the Pharmacokinetics of Fluazuron and Its Residue Elimination in Cattle Tissues. [s.l.] Disserta??o de mestrado,University Yangzhou, 2011. MAFFEI, D. F. Determina??o de res?duos de pesticidas em plasma bovino por cromatografia gasosa-espectrometria de massas. Quimica Nova, v. 32, n. 7, p. 1713?1716, 2009. MAJORS, R. E. Trends in sample preparation. LCGC: Liquid Chromatography, Gas Chromatography, v. 14, n. 9, p. 754?766, 1996. MAJORS, R. E. SamplePreparation Fundamentals for chromatography. Wilmington: Agilent Techonologies, 2014. MARTINS, M. L. et al. Microextra??o L?quido-L?quido Dispersiva ( DLLME ): fundamentos e aplica??es. Scientia Chromatographica, v. 4, n. 1, p. 35?51, 2012. MERCOLINI, L. et al. A fast and feasible microextraction by packed sorbent (MEPS) procedure for HPLC analysis of the atypical antipsychotic ziprasidone in human plasma. Journal of Pharmaceutical and Biomedical Analysis, v. 88, p. 467?471, 2014. MITRA, S. Sample Preparation Techniques In Analytical Chemistry. New Jersey: John Wiley & Sons, Inc, 2003. NAVARRETE, A. et al. Simultaneous online SPE?HPLC?MS/MS analysis of docetaxel, temsirolimus and sirolimus in whole blood and human plasma. Journal of Chromatography B, v. 921, p. 35?42, 2013. NCBI. PubChem Compound Database. Dispon?vel em: <https://pubchem.ncbi.nlm.nih.gov/compound>. Acesso em: 7 abr. 2016. NOGUEIRA, M. et al. T?cnicas de preparo de amostras biol?gicas com interesse forense. Scientia Chromatographica, v. 7, n. 2, p. 125?143, 2015. PANCHAGNULA, R.; THOMAS, N. S. Biopharmaceutics and pharmacokinetics in drug research. International journal of pharmaceutics, v. 201, n. 2, p. 131?50, 2000. PARKER, S. L. et al. A validated method for the quantification of fosfomycin on dried plasma spots by HPLC-MS/MS: Application to a pilot pharmacokinetic study in humans. Journal of Pharmaceutical and Biomedical Analysis, v. 115, p. 509?514, 2015. PEDROSO, R. C. R. Desenvolvimento de m?todos de an?lise por CLAE-UV sulfametoxazol e trimetoprima utilizando sistemas de pr?-concentra??o. [s.l.] Disserta??o de Mestrado,Instituto de Qu?mica,Universidade Federal do Rio Grande do Sul, 2007. PRETO, R. Extra??o em ponteiras descart?veis : fundamentos te?ricos e aplica??es. Scientia Chromatographica, v. 7, n. 2, p. 101?108, 2015. QUEIROZ, S. C. N.; COLLINS, C. H.; JARDIM, I. C. S. F. M?todos de extra??o e/ou concentra??o de compostos encontrados em fluidos biol?gicos para posterior determina??o cromatogr?fica. Quimica Nova, v. 24, n. 1, p. 68?76, 2001. RODRIGUES, M. et al. First liquid chromatographic method for the simultaneous determination of amiodarone and desethylamiodarone in human plasma using microextraction by packed sorbent ( MEPS ) as sample preparation procedure. Journal of Chromatography B, v. 913-914, p. 90?97, 2013. SAID, R. et al. Determination of remifentanil in human plasma by liquid chromatography ? tandem mass spectrometry utilizing micro extraction in packed syringe ( MEPS ) as sample preparation. Journal of Chromatography B, v. 879, n. 11-12, p. 815?818, 2011. SNYDER, L. R.; KIRKLAND, J. J.; DOLAN, J. W. Introduction to Modern Liquid Chromatography. Hoboken, NJ, USA: John Wiley & Sons, Inc., 2009. STORPIRTIS, S. et al. Biofarmacot?cnica. Rio de Janeiro: Guanabara Koogan S.A., 2009. SVANSTR?M, C. et al. Development and validation of a method using supported liquid extraction for the simultaneous determination of midazolam and 1?-hydroxy-midazolam in human plasma by liquid chromatography with tandem mass spectrometry detection. Journal of Pharmaceutical and Biomedical Analysis, v. 58, p. 71?77, 2012. TANKIEWICZ, M.; FENIK, J.; BIZIUK, M. Solventless and solvent-minimized sample preparation techniques for determining currently used pesticides in water samples: A review. Talanta, v. 86, n. 1, p. 8?22, 2011. YAMADA, R. et al. Simultaneous determination of residual veterinary drugs in bovine, porcine, and chicken muscle using liquid chromatography coupled with electrospray ionization tandem mass spectrometry. Bioscience, biotechnology, and biochemistry, v. 70, n. 1, p. 54? 65, 2006. ZHANG, Y. et al. Development of a high-performance liquid chromatography method for quantification of fluazuron in cattle tissues. n. October 2014, p. 2559?2567, 2013.