• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • Tagged with
  • 31
  • 31
  • 25
  • 25
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determinação de macro e microelementos em crustáceos catado comercializados em Salvador, Bahia, Brasil

Prazeres, Marcionila Alexandre Gomes dos January 2011 (has links)
98f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-10T15:28:07Z No. of bitstreams: 1 Dissertação versão final. 2012.pdf: 2926493 bytes, checksum: 7c8eb202f8e1d49db66d28957c7f2ad6 (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-05-10T15:54:03Z (GMT) No. of bitstreams: 1 Dissertação versão final. 2012.pdf: 2926493 bytes, checksum: 7c8eb202f8e1d49db66d28957c7f2ad6 (MD5) / Made available in DSpace on 2013-05-10T15:54:03Z (GMT). No. of bitstreams: 1 Dissertação versão final. 2012.pdf: 2926493 bytes, checksum: 7c8eb202f8e1d49db66d28957c7f2ad6 (MD5) Previous issue date: 2011 / CAPES / Devido a aspectos nutricionais e socioeconômicos os crustáceos possuem grande importância no cenário nacional por serem alimentos usualmente consumidos na região costeira. O objetivo deste trabalho foi avaliar as concentrações de elementos essenciais e não essenciais em amostras de caranguejo, siri e aratu, na forma catada, comercializados em feiras livres na cidade de Salvador, Bahia, Brasil, de forma a traçar um perfil comparativo em termos de concentrações macro e microelementos. As amostras foram adquiridas nos principais pontos de comercialização de pescados da cidade Feira de São Joaquim, Mercado Popular, Feira dois de Julho e CEASA, sendo oriundas de diversas regiões da Baía de Todos os Santos. No pré-tratamento, as amostras foram secas em liofilizador, a moagem foi realizada com moinhos de bolas e o preparo das amostras foi realizado utilizando forno microondas com cavidade, usando uma mistura de ácido nítrico e peróxido de hidrogênio. Para a determinação dos elementos foi empregada a espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). As concentrações encontradas nas amostras variaram expressivamente mesmo quando as mesmas foram indicadas ser de mesmo local de captura. Foram obtidos os seguintes teores médios de concentração, em μg.g-1: para aratu Cu (64,5 ± 1,5), Fe (65,7 ± 2,0), Mn (2,91 ± 0,25), Zn (163 ± 4); para as amostras de caranguejo Cu (53,3 ± 2,5), Fe (69,8 ± 6,0), Mn (3,69 ± 0,31), Zn (309 ± 6); e para as amostras de siri Cu (67,4 ± 3,3), Fe (31,5 ± 3,6), Mn (7,48 ± 2,51), Zn (184 ± 8). As concentrações de todos os elementos analisados mostraram contribuir para o teor de ingestão diária recomendada (IDR). No entanto, as concentrações de Cu e Zn para todas as amostras estão acima do limite máximo de tolerância estabelecido pela ANVISA. Estudos complementares estão sendo realizados visando contribuir para o desenvolvimento de medidas práticas de gerenciamento de modo a proteger a saúde da população. / Salvador
2

Determinação de glifosato e AMPA nas águas superficiais da Bacia do Paraná 3 /

Mendonça, Cintia Franco Rodrigues. January 2018 (has links)
Orientadora: Aline Theodoro Toci / Coorientadora: Helena Redigolo / Banca: Paulo Clairmont Feitosa de Lima Gomes / Banca: Mario Henrique Gonzalez / Resumo: Atualmente, o glifosato é o herbicida de maior uso para o controle de ervas daninhas, sendo muito utilizado em culturas resistentes, como soja e milho. O glifosato é aplicado diretamente sobre a folhagem das plantas, porém uma parte acaba indo para o solo. Do solo, tanto o glifosato quanto seu metabólito, ácido aminometilfosfônico (AMPA) podem ser lixiviados para águas superficiais ou subterrâneas. Por conta disto, têm se gerado preocupações quanto ao seu potencial tóxico. A presente dissertação teve como objetivo avaliar a contaminação com glifosato e AMPA das águas superficiais de microbacias situadas na Bacia do Paraná 3 (Paraná-BR). Selecionou-se microbacias situadas próximas a regiões com plantios de soja e milho, assim como o período de coleta das amostras foi escolhido dentro do época de plantio destas culturas. Estudou-se dois métodos de preparo das amostras de água: reação de derivatização com cloroformiato de 9- fluorenilmetila (FMOC-Cl) seguida de extração e pré-concentração dos analitos com extração em fase sólida (SPE) utilizando cartuchos C18; pré-concentração dos analitos por liofilização seguida de reação de derivatização com FMOC-Cl. Para a determinação de glifosato e AMPA empregou-se cromatografia líquida de alta eficiência (HPLC) com detector de fluorescência. Os resultados demonstraram que a liofilização apresenta maior eficiência no preparo das amostras. Após a escolha do método de preparo realizou-se sua avaliação de desempenho pelos parâmetros de repeti... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Today, glyphosate is the herbicide of greatest consumption for the control o f weeds, widely used in resistant crops such as soybean and corn . Glyphosate is applied directly to the foliage of plants, but part of it ends up going to the soil. From the soil, both glyphosate and its metabolite, aminomethylphosphonic acid ( AMPA ) can be carried to surface water or under ground water. Because of this, concerns have been raised about its toxic potential. In this dissertation, the objective is to evaluate the contamination of surface waters of watersheds located in the Paraná Basin 3 (Paraná - BR) with glyphosate and AMPA. Microbasin located near regions with soybean and corn plantations were chosen, as well as the period of sampling was chosen within the time of planting of these crops . Two methods of preparation of the water samples were stud ied: 9 - Fluorenylmethyl chloroformate ( FMOC - Cl ) derivatization reaction and extraction and pre - concentration of analytes with s olid p hase e xtraction (SPE) using C 18 cartridges; pre - concentration of the analytes with lyophilization followed by derivatization reaction with FMOC - Cl. High p erformance l iquid c hromatography (HPLC) with fluorescence detector was used f or glyphosate and AMPA analysis . The results showed that lyophilization has a better performance in the preparation of the samples. After the choice of the preparation method, its performance evaluation was performed based on evaluation of repeatability, select... (Complete abstract click electronic access below) / Mestre
3

Avaliação de terapias imunossupressoras em transplantes renais com uma abordagem metabolômica / Assessment of immunosuppressive therapies with a metabolomic approach

Cruz, Pedro Luis Rocha da 23 June 2017 (has links)
O aprimoramento das técnicas analíticas viabilizou a metabolômica, uma área da ciência que busca compreender, de forma comparativa, os metabólitos envolvidos nas vias bioquímicas. A metabolômica está inserida no contexto das \"ômicas\", que teve início na \"Era Genômica\", a qual permitiu a identificação de diversos genes. Em seguida, o interesse dos pesquisadores centrou no estudo dos metabólitos (metabolômica) mostrando ser uma ferramenta valiosa na pesquisa do transplante renal, que exige um tratamento medicamentoso por meio de imunossupressores. A combinação destes imunossupressores pode minimizar a rejeição do órgão transplantado, reforçando a necessidade de um estudo metabolômico, a fim de avaliar e comparar as mudanças ocorridas após o transplante em nível molecular, melhorando o conhecimento sobre a influência destes regimes e dando subsídios sobre prognósticos possíveis na área de transplante renal. Nesta tese foram avaliadas 2 terapias: Everolimo/ Prednisona/Tacrolimo (grupo 1) e Micofenolato mofetil/Prednisona/Tacrolimo (grupo 2) a partir de uma abordagem untargeted. No presente trabalho foram coletadas amostras de urina de pacientes ao longo de 6 meses. Foi necessário determinar a melhor condição para análise das amostras de urina dos pacientes. Desta forma, foram realizados estudos sobre alguns parâmetros que impactam no preparo de amostra abordando a influência da urease, tipos e proporção de solventes para precipitação de proteína, seleção do melhor agente derivatizante e tratamento de dados. A avaliação da medida de qualidade dos tratamentos com urease foi feita a partir do desvio padrão relativo (RSD) dos valores de intensidade de pico. A concentração de 10 mg mL-1 apresentou o melhor resultado. O estudo mostrou também que o teor de ureia na urina pode influenciar na identificação dos compostos. O número de compostos identificados foi menor quando a urina não foi tratada com urease, com aproximadamente 10 compostos a menos em relação à amostra tratada com a enzima, na mesma concentração de ureia adicionada. Dos solventes orgânicos testados para precipitação de proteínas nas amostras de urina, o isopropanol mostrou ser o solvente mais adequado na proporção 1:6 urina:solvente (v/v), utilizando-se 100 &#181;L de urina. Foram testados dois protocolos de derivatização para análises por GC-MS: metoximação e sililação utilizando BSTFA e cloroformiato de metila. A comparação mostrou que o procedimento por BSTFA, com 40 metabólitos identificados, foi superior ao cloroformiato de metila, com 13 compostos identificados. No tratamento de dados com o software XCMS, os seguintes parâmetros foram avaliados: largura a meia altura do pico (fwhm), largura da banda (bw) e threshold (sntresh). Para avaliar a melhor combinação destes parâmetros, foi feita uma variação univariada destes valores. A qualidade do resultado de cada combinação foi monitorada pelos valores gerados de número de missing values, quantidade de picos com RSD <15% e número de valores duplicados. Os valores ótimos foram obtidos para a combinação: fwhm=4, bw=2 e threshold=5. A abordagem do estudo dos dois grupos de pacientes baseou-se inicialmente na comparação entre o dia 7 da terapia com os demais períodos (dia 14, mês 1, mês 3 e mês 6) e posteriormente avaliou-se a evolução temporal. A partir do mês 3 os valores de correlação e predição dos modelos de PLS-DA são melhores e já é eficaz na diferenciação entre os dois grupos. Foram observadas perturbações no metabolismo de carboidratos em ambos os grupos, como açúcares, glicerol e N-acetil-D-manosamina. No grupo 1, foram observados metabólitos discriminantes da classe dos poliois e das vias do ciclo do ácido cítrico e degradação de xenobióticos, enquanto que, no grupo 2, foi observada alteração do hidroxibutirato, um corpo cetônico. Neste grupo, foi observado também um aumento do ácido hipúrico, ácido acetamido butírico, ácido benzoico, entre outros. Nesta tese foi possível demonstrar que a metabolômica é uma ferramenta importante para comparar metabólitos discriminantes entre dois regimes imunossupressores, sendo um estudo piloto que visa fornecer subsídios para avaliação da influência destas terapias no prognóstico de transplante renal. / The improvement of analytical techniques enabled the emergence of metabolomics, which aims to compare the metabolites involved in biochemical pathways, in certain biological conditions. Metabolomics is inserted in the \"omics\" context, which began in the \"Genomic Age\", and allowed the identification of several genes. After that, the researchers focused on the study of metabolites. Among several applications, metabolomics can be a valuable tool in renal transplant research, which requires a drug treatment through immunosuppressants. The combination of these immunosuppressants can minimize toxicity and rejection of the transplanted organ, reinforcing the need for a metabolomic study, in order to evaluate and compare changes after transplantation at the molecular level, improving knowledge about the influence of these regimens and giving subsidies on prognosis in the area of renal transplantation. In this thesis two immunosuppressive therapies were evaluated by an untargeted approach: Everolimus/Prednisone/Tacrolimus (group 1) and Mycophenolate mofetil/Prednisone/Tacrolimus (group 2). In this study, urine samples were collected from patients over 6 months. It was necessary to determine the best condition for analysis of patients\' urine samples. Thus, studies were carried out on some parameters that impact on sample preparation, evaluating the influence of urease, types and proportion of solvents for protein precipitation, selection of the best derivatizing agent, and data treatment. The evaluation of the quality measure of the urease treatments was made from the relative standard deviation (RSD) of the peak intensity values. The concentration of 10 mg mL-1 presented the best result. The study also showed that urine urea content may influence the identification of the compounds. The number of identified compounds was lower when urine was not treated with urease, with approximately 10 compounds less than the enzyme-treated sample, at the same concentration of urea added. In the evaluation of the organic solvents tested for protein precipitation in the urine samples, isopropanol was the most suitable solvent in the ratio 1: 6 urine:solvent (v/v), using 100 &#181;L of urine. Two derivatization protocols were tested for GC-MS analysis: metoximation and silylation with BSTFA and methyl chloroformate. The comparison between the two derivatization protocols showed that the BSTFA procedure, with 40 identified metabolites, was superior to methyl chloroformate with 13 compounds identified. In data processing with the XCMS software, the following parameters were evaluated: full width at half maximum of the peak (fwhm), bandwidth (bw) and threshold (sntresh). To evaluate the best combination of these parameters, a univariate variation of these values was made. The quality of the result of each combination was monitored by the number of missing values, number of peaks with RSD <15%, and number of duplicate values. The optimal values were obtained for the combination: fwhm=4, bw=2 and threshold =5. The study of the two groups of patients was initially based on the comparison between day 7 of the therapy with the other periods (day 14, month 1, month 3 and month 6) and later the temporal evolution was evaluated. From month 3 the values of correlation and prediction of the PLS-DA models are better and already effective in the differentiation between the two groups. Disorders in carbohydrate metabolism were observed in both groups with sugars and glycerol and N-acetyl-D-mannosamine as discriminant metabolites. In group 1, discriminant metabolites of the class of polyols and citric acid cycle pathways and degradation of xenobiotics were observed, and in group 2 alteration of hydroxybutyrate, a ketone body, was observed. In this group an increase of hippuric acid, acetamido butyric acid, benzoic acid, among others, was also observed. In this thesis it was possible to demonstrate that metabolomics is an important tool to compare discriminant metabolites between two immunosuppressive regimens, being a pilot study that aims to provide future subsidies to evaluate the influence of these therapies on the renal transplant prognosis
4

Emprego de um polímero de impressão molecular restrito à ligação com macromoléculas por meio de revestimento com albumina para extração on-line de ivermectina em carne bovina seguido de análise por HPLC-UV

LIMA, Marcela Marília de 21 January 2014 (has links)
A ivermectina (IVM) é um antiparasitário mundialmente utilizado na criação de animais. No entanto, quando o tempo de carência não é respeitado, resíduos de IVM são encontrados nos produtos de origem animal podendo causar danos à saúde humana. Assim, foi estabelecido em diversos países um limite máximo de resíduo (LMR) para este fármaco. Portanto, amostras de carne contendo IVM acima dos valores estabelecidos são consideradas adulteradas e têm sido a causa do embargo das exportações de carne bovina do Brasil, que é atualmente o maior país exportador deste produto no mundo. Os níveis de resíduos de IVM nos tecidos geralmente são muito baixos, pois este fármaco é capaz de produzir efeito terapêutico em pequenas doses. Assim, é necessário o emprego de técnicas sensíveis e seletivas de preparo de amostras e análise para verificar a presença de IVM em carne. Neste sentido, o principal objetivo deste trabalho foi sintetizar um polímero de impressão molecular restrito à ligação com macromoléculas por meio de revestimento com albumina (RAMIP-BSA), e empregar o mesmo na extração on-line de IVM em extratos proteicos de carne bovina, seguido de análise por cromatografia líquida de alta eficiência (CLAE) com detector por absorção no ultravioleta (UV). A IVM foi inicialmente extraída de amostras de carne moída empregando-se uma mistura de metanol:água (70:30, v/v), e o extrato resultante foi diretamente analisado pelo sistema on-line de extração e separação. O método apresentou linearidade na faixa de 50 a 500 μg kg-1 com precisão de 3,8 a 17,0% e exatidão de -18,5 a 22,0%. Os limites de detecção e quantificação foram de 30 e 50 μg kg-1, respectivamente, sendo menores que o LMR para IVM em carne bovina que é de 100 μg kg-1. O método foi considerado robusto e seletivo, tendo sido empregado com sucesso na monitorização de IVM em amostras de carne bovina. / Ivermectn (IVM) is an antiparasitic drug worldwide used in livestock. However, when the grace period is not respected, IVM residues can be found in animal source products and can cause damages to the human health. Thus, it was established in many countries a maximum limit of residue (MRL) to this drug. Therefore, meat samples that contain IVM above the established values are considered adulterated and have been the cause of exportations embargo of meat from Brazil. IVM is able to produce a therapeutic effect even in lower doses. Hence, the residues levels in the tissues are usually very low, which makes necessary the use of selective and sensitive techniques of sample preparation and analysis. Thus, the main objective of this work was to synthesize a restricted access molecularly imprinted polymer coated with bovine serum albumin (RAMIP-BSA) and to employ it in the on-line extraction of IVM in minced meat samples, followed by a high performance liquid chromatography (HPLC) with an UV detector. The method has shown linearity from 50 to 500 μg kg-1, with precision and accuracy ranging from 3.8 to 17.0 and from -18.5 to 22.0, respectively. The detection and quantification limits were 30 e 50 μg kg-1 respectively. The method can be used in the monitoring of IVM in beef samples.
5

Avaliação de terapias imunossupressoras em transplantes renais com uma abordagem metabolômica / Assessment of immunosuppressive therapies with a metabolomic approach

Pedro Luis Rocha da Cruz 23 June 2017 (has links)
O aprimoramento das técnicas analíticas viabilizou a metabolômica, uma área da ciência que busca compreender, de forma comparativa, os metabólitos envolvidos nas vias bioquímicas. A metabolômica está inserida no contexto das \"ômicas\", que teve início na \"Era Genômica\", a qual permitiu a identificação de diversos genes. Em seguida, o interesse dos pesquisadores centrou no estudo dos metabólitos (metabolômica) mostrando ser uma ferramenta valiosa na pesquisa do transplante renal, que exige um tratamento medicamentoso por meio de imunossupressores. A combinação destes imunossupressores pode minimizar a rejeição do órgão transplantado, reforçando a necessidade de um estudo metabolômico, a fim de avaliar e comparar as mudanças ocorridas após o transplante em nível molecular, melhorando o conhecimento sobre a influência destes regimes e dando subsídios sobre prognósticos possíveis na área de transplante renal. Nesta tese foram avaliadas 2 terapias: Everolimo/ Prednisona/Tacrolimo (grupo 1) e Micofenolato mofetil/Prednisona/Tacrolimo (grupo 2) a partir de uma abordagem untargeted. No presente trabalho foram coletadas amostras de urina de pacientes ao longo de 6 meses. Foi necessário determinar a melhor condição para análise das amostras de urina dos pacientes. Desta forma, foram realizados estudos sobre alguns parâmetros que impactam no preparo de amostra abordando a influência da urease, tipos e proporção de solventes para precipitação de proteína, seleção do melhor agente derivatizante e tratamento de dados. A avaliação da medida de qualidade dos tratamentos com urease foi feita a partir do desvio padrão relativo (RSD) dos valores de intensidade de pico. A concentração de 10 mg mL-1 apresentou o melhor resultado. O estudo mostrou também que o teor de ureia na urina pode influenciar na identificação dos compostos. O número de compostos identificados foi menor quando a urina não foi tratada com urease, com aproximadamente 10 compostos a menos em relação à amostra tratada com a enzima, na mesma concentração de ureia adicionada. Dos solventes orgânicos testados para precipitação de proteínas nas amostras de urina, o isopropanol mostrou ser o solvente mais adequado na proporção 1:6 urina:solvente (v/v), utilizando-se 100 &#181;L de urina. Foram testados dois protocolos de derivatização para análises por GC-MS: metoximação e sililação utilizando BSTFA e cloroformiato de metila. A comparação mostrou que o procedimento por BSTFA, com 40 metabólitos identificados, foi superior ao cloroformiato de metila, com 13 compostos identificados. No tratamento de dados com o software XCMS, os seguintes parâmetros foram avaliados: largura a meia altura do pico (fwhm), largura da banda (bw) e threshold (sntresh). Para avaliar a melhor combinação destes parâmetros, foi feita uma variação univariada destes valores. A qualidade do resultado de cada combinação foi monitorada pelos valores gerados de número de missing values, quantidade de picos com RSD <15% e número de valores duplicados. Os valores ótimos foram obtidos para a combinação: fwhm=4, bw=2 e threshold=5. A abordagem do estudo dos dois grupos de pacientes baseou-se inicialmente na comparação entre o dia 7 da terapia com os demais períodos (dia 14, mês 1, mês 3 e mês 6) e posteriormente avaliou-se a evolução temporal. A partir do mês 3 os valores de correlação e predição dos modelos de PLS-DA são melhores e já é eficaz na diferenciação entre os dois grupos. Foram observadas perturbações no metabolismo de carboidratos em ambos os grupos, como açúcares, glicerol e N-acetil-D-manosamina. No grupo 1, foram observados metabólitos discriminantes da classe dos poliois e das vias do ciclo do ácido cítrico e degradação de xenobióticos, enquanto que, no grupo 2, foi observada alteração do hidroxibutirato, um corpo cetônico. Neste grupo, foi observado também um aumento do ácido hipúrico, ácido acetamido butírico, ácido benzoico, entre outros. Nesta tese foi possível demonstrar que a metabolômica é uma ferramenta importante para comparar metabólitos discriminantes entre dois regimes imunossupressores, sendo um estudo piloto que visa fornecer subsídios para avaliação da influência destas terapias no prognóstico de transplante renal. / The improvement of analytical techniques enabled the emergence of metabolomics, which aims to compare the metabolites involved in biochemical pathways, in certain biological conditions. Metabolomics is inserted in the \"omics\" context, which began in the \"Genomic Age\", and allowed the identification of several genes. After that, the researchers focused on the study of metabolites. Among several applications, metabolomics can be a valuable tool in renal transplant research, which requires a drug treatment through immunosuppressants. The combination of these immunosuppressants can minimize toxicity and rejection of the transplanted organ, reinforcing the need for a metabolomic study, in order to evaluate and compare changes after transplantation at the molecular level, improving knowledge about the influence of these regimens and giving subsidies on prognosis in the area of renal transplantation. In this thesis two immunosuppressive therapies were evaluated by an untargeted approach: Everolimus/Prednisone/Tacrolimus (group 1) and Mycophenolate mofetil/Prednisone/Tacrolimus (group 2). In this study, urine samples were collected from patients over 6 months. It was necessary to determine the best condition for analysis of patients\' urine samples. Thus, studies were carried out on some parameters that impact on sample preparation, evaluating the influence of urease, types and proportion of solvents for protein precipitation, selection of the best derivatizing agent, and data treatment. The evaluation of the quality measure of the urease treatments was made from the relative standard deviation (RSD) of the peak intensity values. The concentration of 10 mg mL-1 presented the best result. The study also showed that urine urea content may influence the identification of the compounds. The number of identified compounds was lower when urine was not treated with urease, with approximately 10 compounds less than the enzyme-treated sample, at the same concentration of urea added. In the evaluation of the organic solvents tested for protein precipitation in the urine samples, isopropanol was the most suitable solvent in the ratio 1: 6 urine:solvent (v/v), using 100 &#181;L of urine. Two derivatization protocols were tested for GC-MS analysis: metoximation and silylation with BSTFA and methyl chloroformate. The comparison between the two derivatization protocols showed that the BSTFA procedure, with 40 identified metabolites, was superior to methyl chloroformate with 13 compounds identified. In data processing with the XCMS software, the following parameters were evaluated: full width at half maximum of the peak (fwhm), bandwidth (bw) and threshold (sntresh). To evaluate the best combination of these parameters, a univariate variation of these values was made. The quality of the result of each combination was monitored by the number of missing values, number of peaks with RSD <15%, and number of duplicate values. The optimal values were obtained for the combination: fwhm=4, bw=2 and threshold =5. The study of the two groups of patients was initially based on the comparison between day 7 of the therapy with the other periods (day 14, month 1, month 3 and month 6) and later the temporal evolution was evaluated. From month 3 the values of correlation and prediction of the PLS-DA models are better and already effective in the differentiation between the two groups. Disorders in carbohydrate metabolism were observed in both groups with sugars and glycerol and N-acetyl-D-mannosamine as discriminant metabolites. In group 1, discriminant metabolites of the class of polyols and citric acid cycle pathways and degradation of xenobiotics were observed, and in group 2 alteration of hydroxybutyrate, a ketone body, was observed. In this group an increase of hippuric acid, acetamido butyric acid, benzoic acid, among others, was also observed. In this thesis it was possible to demonstrate that metabolomics is an important tool to compare discriminant metabolites between two immunosuppressive regimens, being a pilot study that aims to provide future subsidies to evaluate the influence of these therapies on the renal transplant prognosis
6

Comparação de métodos de tratamento de amostras de biodiesel para determinação de Sódio usando espectrometria de absorção atômica com chama / Comparison of treatment methods for biodiesel samples for determination of Sodium using flame atomic absorption spectrometry

Leonardo, Ana Cristina de Almeida 22 July 2016 (has links)
Submitted by Rosivalda Pereira (mrs.pereira@ufma.br) on 2017-06-02T19:35:12Z No. of bitstreams: 1 AnaLeonardo.pdf: 617676 bytes, checksum: b538fd3ffdb436a8e246ec2a0e138840 (MD5) / Made available in DSpace on 2017-06-02T19:35:12Z (GMT). No. of bitstreams: 1 AnaLeonardo.pdf: 617676 bytes, checksum: b538fd3ffdb436a8e246ec2a0e138840 (MD5) Previous issue date: 2016-07-22 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPQ) / Most analytical methods require a sample preparation to make it compatible with the technique and the equipment used. This paper proposes a comparison between alkaline solubilization using TMAH 25% and acid extraction with heating using HNO3 0.1 mol L -1 as preparation of biodiesel samples in order to determine sodium. The analytical technique used in this study was Flame Atomic Absorption Spectrometry - FAAS. The biodiesel samples used were synthesized from three commercially available oils: babassu oil, corn and soybeans. The interlaboratory biodiesel sample used to compare the proposed method with the official NBR 15556:2008, was provided by Laboratory of Analysis and Research in Analytical Chemistry of Petroleum and Biofuels - LAPQAP/UFMA. The final solution after solubilization with 25% TMAH in methanol was incompatible with FAAS technique. The high viscosity of the sample influenced directly in the aspiration causing significant variations in the readings and making it impossible to continue the analysis. Acid extraction HNO3 0.1mol.L -1 yielded better results, in addition, the physical conditions of the final solution were consistent with FAAS. The LOD and LOQ values were respectively 0.02 and 0.07 mg.Kg-1 for sodium. The obtained recoveries were between 102 and 110% at three different levels of fortification. In comparison with the dilution of biodiesel in xylene established by official standards, quantified concentrations showed values very close. The simplicity, accuracy, precision, less toxicity and low cost of the acidic extraction method suggest that this may be a good alternative for treating biodiesel sample to determine sodium. / A maioria dos métodos analíticos precisa de um preparo da amostra para torná-la compatível com a técnica e o equipamento utilizado. Este trabalho propõe uma comparação entre a solubilização alcalina usando TMAH 25% e a extração ácida com aquecimento usando HNO3 0,1 mol.L-1 como preparo das amostras de biodiesel visando a determinação de sódio. A técnica analítica utilizada no presente trabalho foi Espectrometria de Absorção Atômica com Chama FAAS. As amostras de biodiesel utilizadas foram sintetizadas a partir de três óleos vegetais disponíveis no comércio: babaçu, milho e soja. O Biodiesel interlaboratorial usado na comparação do método proposto com a norma oficial NBR 15556:2008, foi cedido pelo Laboratório de Análise e Pesquisa em Química Analítica de Petróleo e Biocombustíveis - LAPQAP/UFMA. A solução final após a solubilização com TMAH 25% em metanol foi incompatível com FAAS. A alta viscosidade da amostra influenciou diretamente na aspiração causando variações significativas nas leituras impossibilitando a continuidade das análises. A extração ácida com HNO3 0,1mol.L-1 proporcionou melhores resultados, além disso, as condições físicas da solução final foram consistentes com FAAS. Os valores de LD e LQ foram respectivamente: 0,02 e 0,07 mg.Kg-1 para sódio. A recuperação obtida foi entre 102 e 110 % em três níveis diferentes de fortificação. Na comparação com a diluição do biodiesel em xileno estabelecido pelas normas oficiais, as concentrações quantificadas apresentaram valores bem próximos. A simplicidade, exatidão, precisão, menor toxicidade e baixo custo do método de extração ácida, sugerem que esta pode ser uma boa alternativa de tratamento de amostra de biodiesel para determinação de sódio.
7

Estudo comparativo de m?todos de extra??o para determina??o de fluazuron em plasma bovino por cromatografia l?quida de alta efici?ncia com detec??o em ultravioleta. / Comparison of extraction methods for determining fluazuron in bovine plasma by high-performance liquid chromatography with UV detection.

Ferreira, Thais Paes 11 May 2016 (has links)
Submitted by Leticia Schettini (leticia@ufrrj.br) on 2016-10-04T13:00:01Z No. of bitstreams: 1 2016 - Thais Paes Ferreira.pdf: 1131707 bytes, checksum: c98267296d6293f703188fe1291622db (MD5) / Made available in DSpace on 2016-10-04T13:00:01Z (GMT). No. of bitstreams: 1 2016 - Thais Paes Ferreira.pdf: 1131707 bytes, checksum: c98267296d6293f703188fe1291622db (MD5) Previous issue date: 2016-05-11 / Fluazuron is a benzoylphenylurea acarine growth inhibitor that is marketed for the control of cattle tick. Although the growth regulators are widely studied class, the number of papers describing analytical methods for determining the fluazuron in plasma samples is reduced. The development of a simple and fast analytical method for quantifying fluazuron in bovine plasma by HPLC-UV enables the evaluation of drug plasma profile and can be applied on bioavailability analysis of formulations containing fluazuron. In recent years there has been a technological breakthrough for chromatographic instrumentation, providing rapid, robust and sensitive methods, but the pretreatment of the sample stage becomes the limiting factor in this process. New extraction methods have been developed, however are often complex, expensive methods and are not as sophisticated to handle complex matrices, such as plasma. The aim of this study was a comparative study of three extraction methods: LLE, SPE and matrix solid phase dispersion (MSPD). Pooled plasma samples were used as biological material, partly as raw samples and partly spiked with concentrations of fluazuron. For each extraction method (with exception of DMFS) was conducted using various solvents (ethyl acetate, dichloromethane, diethyl ether, hexane and acetonitrile) in order to evaluate the best extractor solvent. After the extractions the samples were concentrated and analyzed by HPLC/UV. The chromatographic separation was achieved on Kromasil C18 column preceded by guard column of matching chemistry, with mobile phase of acetonitrile: water (80:20, v/v) at flow rate of 1.0 mL/min. The comparative analysis of the extraction procedures was based on selectivity, precision and accuracy of the method. Results showed that LLE not presented accuracy (< 80 and >120%) and precision (CV > 15%) with any solvent tested. SPE method showed good accuracy (80-120%) and precision (CV < 15%) for ethyl acetate, dichloromethane and diethyl ether. MSPD method using ethyl acetate solvent showed good accuracy and precision. However, SPE also allows a lower solvent consumption and shorter analysis time. The validation of the analytical method showed linearity, selectivity, precision, accuracy and, absence matrix effects and residual, thus proving it as suitable for routine analysis; This method showed to be an important investigative tool in the analysis of fluazuron plasma concentration in cattle. Fluazuron topical administration in bovine reached the systemic circulation (Cmax=62,8 ng/mL), was absorbed (tmax=48 hs), while maintaining quantifiable blood plasma levels for up to 14 days after the treatment with a 2,5 mg/Kg dosage. / Fluazuron ? um inibidor do crescimento da classebenzoilfenilur?ia, sendo comercializado para o controle de carrapatos do gado. Embora a classe de reguladores de crescimento sejam amplamente estudada, o n?mero de artigos que descrevem os m?todos anal?ticos para a determina??o do fluazurom em amostras de plasma ? escasso. O desenvolvimento de um m?todo anal?tico simples e r?pido para quantificar fluazuron em plasma bovino por CLAEUV permite a avalia??o do perfil plasm?tico do f?rmaco e pode ser aplicado na an?lise de biodisponibilidade de formula??es contendo fluazurom. Nos ?ltimos anos, tem acontecido um avan?o tecnol?gico para a instrumenta??o cromatogr?fica, proporcionando m?todos r?pidos, eficazes e sens?veis, mas a etapa de pr?-tratamento da amostra torna-se o fator limitante neste processo. Novos m?todos de extra??o t?m sido desenvolvidos, no entanto, muitas das vezes s?om?todos complexos, caros e n?o t?o sofisticados para matrizes complexas como o plasma. O objetivo deste estudo foi um estudo comparativo de tr?s m?todos de extra??o: extra??o l?quido-l?quido (ELL), extra??o em fase s?lida (EFS) e dispers?o de matriz em fase s?lida (DMFS). Ums mistura de amostras de plasma foi utilizada como material biol?gico, uma parte como amostra bruta e outra parcialmente enriquecida com concentra??es de fluazuron. Para cada m?todo de extra??o (exceto DMFS) foram analisadosdiversos solventes (acetato de etila, diclorometano, ?ter diet?lico, hexano e acetonitrila), a fim de avaliar o melhor solvente extrator. Ap?s as extra??es, as amostras foram concentradas e analisadas por CLAE/UV. A separa??o cromatogr?f ica foi obtida na coluna Kromasil C18 precedida de pr?-coluna de fase qu?mica correspondente, com fase m?vel de acetonitrila: ?gua (80:20, v/v) a um fluxo de 1,0 mL /min. A an?lise comparativa dos procedimentos de extra??o foi baseada na seletividade, precis?o e exatid?o do m?todo. Os resultados mostraram que a precis?o ELL n?o apresentou exatid?o (<80 e> 120%) e precis?o (CV> 15%) com nenhum dos solventes analisados. O m?todo EFS mostrou boa exatid?o (80-120%) e precis?o (CV <15%) para o acetato de etila, diclorometano e ?ter diet?lico. O m?todo de DMFS utilizando o solvente acetato de etila mostrou boa exatid?o e precis?o. No entanto, a EFS tamb?m permite um menor consumo de solventes e um tempo curto de an?lise; A valida??o do m?todo anal?tico mostrou linearidade, seletividade, precis?o, exatid?o e, aus?ncia de efeitos de matriz e residual, demonstrando-se adequado para an?lises de rotina; Este m?todo mostrou-se uma ferramenta de investiga??o importante na an?lise de concentra?? plasm?tica em bovinos. Fluazuron administrado por via t?pica em bovinos atingiu a circula??o sist?mica (Cmax = 62,8 ng /ml) e foi absorvido (Tm?x = 48 Hs), se mantendo quantificav?l em n?veis plasm?ticos por at? 14 dias ap?s o tratamento com uma dosagem de 2,5 mg / kg.
8

Emprego de sistema em fluxo a altas temperatura e pressão no preparo de amostras de leite e sangue de bovinos / Use of high temperature and high pressure flow system for bovine milk and blood sample preparation

Barros, Allen Lopes de 17 October 2008 (has links)
No presente trabalho, um sistema em fluxo operando sob altas temperaturas e pressão foi avaliado, com o objetivo de solubilizar amostras de sucos, leite e sangue de bovinos para a determinação de constituintes inorgânicos. O sistema emprega uma bomba de alta pressão utilizada em cromatografia líquida para o transporte dos líquidos através de um tubo capilar metálico aquecido e de um capilar restritor de menor diâmetro interno, com a finalidade de se obter digeridos ácidos das amostras em estudo. A eficiência da digestão foi avaliada a partir da determinação do carbono residual, realizada por espectrometria de emissão óptica com plasma de argônio indutivamente acoplado. Espectrometria de absorção atômica com chama e geração de hidretos voláteis foi usada para as determinações de selênio. Foram exploradas diferentes configurações relacionadas ao sistema, tais como emprego de um capilar restritor e da bobina digestora construída em aço inoxidável com diferentes comprimentos, pressões de trabalho e formas de introdução das amostras, além da proposta alternativa para a inserção de amostras que permitiu contornar a inconveniente precipitação das proteínas antes da entrada das amostras no sistema. Para isso, configuração que possibilitou mistura entre a amostra e os reagentes por confluência no interior do sistema sem prévia mistura foi avaliada. Os resultados indicaram a viabilidade do sistema, com a redução do carbono residual em mais de 60 %. Porém, problemas relacionados a perdas de elementos por volatilização necessitam ser contornados. / A flow injection system, operated under high temperature and high pressure conditions has been evaluated concerning the dissolution of fruit juices and samples of bovine milk and blood for the determination of inorganic constituents. In this system, a high pressure liquid chromatography pump was used for the transportation of liquid samples through a stainless steel heated capillary and finally through a restrictor capillary, which has a shorter inner diameter, so that the digestion of the samples could be attained. The residual carbon contents were determined by inductively coupled plasma atomic emission spectrometry. Hydride generation flame atomic absorption spectrometry was used for selenium determinations. Different configurations for the flow system were evaluated, such as variable lengths for the restrictor and digestion capillaries. Different working pressures as well as different ways for the sample introduction were tried out, being reached an alternative that avoided the precipitation of proteins before the introduction of the samples in the system. For this purpose, a configuration in which the contact between sample and reagents occurs inside the system, with no previous mixture, was evaluated. The results indicated the viability of the system which used the confluence configuration. Although digestion efficiency of 60 % was observed for milk samples, problems related to volatilization have to be circumvented.
9

Avaliação de estratégias para melhoria da sensibilidade em análises por espectrometria de emissão óptica com plasma induzido por laser / Evaluation of strategies to improve sensitivity in analyzes by laser induced breakdown spectroscopy

Lázaro, Maisa Cristina [UNESP] 09 August 2017 (has links)
Submitted by MAISA CRISTINA LAZARO null (maisalazaro_mcl@hotmail.com) on 2017-09-05T15:09:44Z No. of bitstreams: 1 Dissertação Mestrado_Repositório.pdf: 1448238 bytes, checksum: f02ad2ea0e02cac8044c4645b5fd43f7 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-09-06T16:16:31Z (GMT) No. of bitstreams: 2 lazaro_mc_me_araiq_par.pdf: 540678 bytes, checksum: 2e6053c1e59ea8b435722b01fd52317a (MD5) lazaro_mc_me_araiq_int.pdf: 1448238 bytes, checksum: f02ad2ea0e02cac8044c4645b5fd43f7 (MD5) / Made available in DSpace on 2017-09-06T16:16:31Z (GMT). No. of bitstreams: 2 lazaro_mc_me_araiq_par.pdf: 540678 bytes, checksum: 2e6053c1e59ea8b435722b01fd52317a (MD5) lazaro_mc_me_araiq_int.pdf: 1448238 bytes, checksum: f02ad2ea0e02cac8044c4645b5fd43f7 (MD5) Previous issue date: 2017-08-09 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A espectrometria de emissão óptica em plasma induzido por laser (LIBS) é uma técnica que vem se desenvolvendo cada vez mais para determinações analíticas multielementares, com aplicações em diversas áreas. Possui várias vantagens, como por exemplo, ser uma técnica de análise rápida, minimamente destrutiva e ambientalmente amigável, enquanto que a maior dificuldade está baseada na sua relativa baixa sensibilidade. Muitos estudos têm sido desenvolvidos com a finalidade de melhorar a sensibilidade, porém os aprimoramentos elaborados demandam equipamentos mais sofisticados, aumentando o custo e comprometendo a portabilidade da técnica. O presente trabalho avaliou estratégias simples para melhorar a sensibilidade das medidas em LIBS, permitindo o uso de instrumentos compactos de pulso simples. As estratégias desenvolvidas se baseiam na proposição da introdução de uma etapa simples de pré-tratamento da amostra, capaz de agir na fragilização de estruturas químicas que por consequência levem ao aumento das intensidades de emissão das espécies componentes da amostra. As etapas de pré-tratamentos buscam em sua essencialidade não descaracterizar as vantagens analíticas de LIBS, tais como a simplicidade e a não utilização de reagentes potencialmente tóxicos, além de serem aplicáveis à diversos tipos de amostras. A ação da temperatura sobre a modificação de estruturas químicas foi avaliada utilizando aquecimento em mufla para amostra de material vegetal, solo e liga metálica e em forno de micro-ondas para amostra vegetal. Os tratamentos empregados utilizando aquecimento em mufla resultaram em aumentos nas intensidades de emissão em toda região espectral para todas as amostras avaliadas; para a amostra de folha, material para o qual foram obtidos os melhores resultados, foram verificados aumentos de 47x com relação à área de pico da linha de Ca I em 612,14 nm, além do aparecimento de linhas antes não observadas, como a de Sr II em 407,82 nm. Para a amostra de liga, a área da linha de Fe I em 489,22 nm teve um aumento de 8x e para a amostra de solo, a linha de Na em 588,89 nm, por exemplo, teve seu valor de área aumentado em 4x com a aplicação do tratamento térmico. O aquecimento em micro-ondas forneceu incrementos de intensidade menos pronunciados, comparados ao aquecimento em mufla. Adicionalmente foi avaliada a introdução de fundente à amostra de solo com o intuito de melhorar processos físicos, os quais poderiam culminar em aumento dos processos de emissão dos analitos da amostra, entretanto, esta estratégia não atingiu o objetivo proposto. Por fim, o tratamento térmico em mufla foi aplicado no desenvolvimento de um método para determinação de Sr em material foliar utilizando LIBS. O método desenvolvido apresentou curva analítica linear com coeficiente de correlação igual a 0,997, limite de detecção igual a 4,23 mg kg-1 e limite de quantificação igual a 14,09 mg kg-1. A análise de material de referência certificado foliar pelo método proposto indicou que a concentração de Sr determinada é concordante com o valor certificado a 95% de confiança (test t pareado). / Laser-induced breakdown spectroscopy (LIBS) is an analytical technique in development, increasingly applied for multielemental determinations in several areas. It shows several advantages, such as rapidity, minimally destructive and environmentally friendly, although the greatest difficulty is based on its relatively low sensitivity. Many efforts have been expended to improve LIBS sensitivity, but several proposals require more sophisticated equipment, increasing the cost and compromising the portability of the technique. The present work evaluated simple strategies to improve the sensitivity of LIBS measurements allowing the use of compact single pulse instruments. The proposed strategies are based on a simple sample pretreatment, able to promotes simplification of chemical structures, which could lead to an increase of emission intensities. The proposed pretreatment steps aimed to preserve the interesting LIBS analytical advantages, such as its simplicity and non-use of toxic reagents, and its applicability to several types of samples. Then the temperature action on the simplification of chemical structures was evaluated using conventional muffle oven, for samples of plant leaves, soil and metal alloy. Additionally, microwave oven heating was evaluated for plant leaves. The muffle oven treatments resulted in important increases of the emission intensities for all spectral region of all evaluated samples; for the plant leaves, material for which the best results were observed, the integrated peak area of the Ca I line at 612.14 nm was increased about 47x after the thermic treatment. Moreover, new emission lines, not observed before, such as Sr II line at 407.82 nm, appeared. In the alloy sample, the integrated area of Fe I line at 489.22 nm showed an increase of 8x and in soil sample the Na I line at 588.89 nm, showed an increasing of 4x. The microwave heating provided less pronounced intensity increments compared to the muffle heating. The mixture of the soil sample with chemical modifier was also evaluated in order to improve physical processes, which could lead to an increasing of the emission signals. Nevertheless, this strategy did not reach the expected. Finally, the heat treatment in muffle was applied in the development of a method for determination of Sr in leaf material using LIBS. The developed method presented a linear analytical curve with correlation coefficient of 0.997, limit of detection of 4.23 mg kg -1 and limit of quantification of 14.09 mg kg-1 . Analysis of leaf reference material by the proposed method indicated the determined concentration of Sr is in agreement with the certified value at 95% confidence (paired t-test). / CNPq: 830856/1999-4
10

Avaliação de métodos analíticos para determinação da composição mineral em derivados de soja empregando técnicas espectrométricas

Barbosa, José Tiago Pereira 04 1900 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-09-12T17:29:38Z No. of bitstreams: 1 Dissertação José Tiago Pereira Barbosa.pdf: 1750358 bytes, checksum: e01d971ee45a1ab67fd25d7981b87383 (MD5) / Approved for entry into archive by NUBIA OLIVEIRA (nubia.marilia@ufba.br) on 2016-09-12T18:21:30Z (GMT) No. of bitstreams: 1 Dissertação José Tiago Pereira Barbosa.pdf: 1750358 bytes, checksum: e01d971ee45a1ab67fd25d7981b87383 (MD5) / Made available in DSpace on 2016-09-12T18:21:31Z (GMT). No. of bitstreams: 1 Dissertação José Tiago Pereira Barbosa.pdf: 1750358 bytes, checksum: e01d971ee45a1ab67fd25d7981b87383 (MD5) / CAPEs / A proteína texturizada de soja possui alto conteúdo protéico e é usualmente utilizada como alternativa na substituição de uma porção de carne. O objetivo deste trabalho foi avaliar três procedimentos de decomposição úmida, visando determinação multielementar (Ca, K, Mg, P, Cr, Cu, Fe, Mn, Ni e Zn) em amostras de proteína texturizada de soja por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Nos procedimentos usando chapa aquecedora (PC) e bloco digestor (PB) foi utilizada a mistura de HNO3 e H2O2, enquanto que para o procedimento com forno de microondas focalizadas (PF) foi necessária a introdução também de H2SO4. As figuras analíticas de mérito, tais como precisão, limites de detecção (LOD) e quantificação (LOQ) e efeito de matriz, foram avaliadas para os procedimentos propostos. As concentrações de Al, Cd, Co e Pb, encontraram-se abaixo do LOQ dos procedimentos para as amostras. A exatidão foi verificada com material de referência certificado e por comparação com método de referência da AOAC. Além disso, foi otimizado um sistema miniaturizado de análise por injeção em fluxo visando a determinação de ferro nos digeridos com o reagente 1,10- fenantrolina e os resultados foram concordantes com o método de referência. / The texturized soy protein is a good source of protein and is usually used as an alternative to meat. The aim of this study was the evaluation of three wet decomposition procedures for multi-element analytical determination (Ca, K, Mg, P, Cr, Cu, Fe, Mn, Ni e Zn) in texturized soy protein samples using inductively coupled plasma optical emission spectrometry (ICP OES). In procedures using hot plate (PC) and heating block (PB), a mixture of HNO3 and H2O2 was used, whereas for decomposition in a focused-microwave-oven (PF), the use of H2SO4 was necessary. The analytical figures of merit of the developed analytical procedures such as precision, accuracy and matrix effect, were statistically assessed. The concentrations of Al, Cd, Co and Pb were found below oh the LOQ. The accuracy of the results was demonstrated using one certified reference material (spinach leaves NIST 1570a) and comparison with recommended AOAC official method. Moreover, a flow injection analysis microsystem for determination of iron with 1,10-phenantroline was optimized and the results were concordant with those obtained with the reference method.

Page generated in 0.1063 seconds