Return to search

Análise experimental de bloco de fundação sobre duas estacas, sob carga centrada, para estruturas pré-fabricadas

Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Engenharia Civil / Made available in DSpace on 2012-10-23T15:39:18Z (GMT). No. of bitstreams: 1
254972.pdf: 3212263 bytes, checksum: 21bd70024bb518a31562b3dbee4a3dad (MD5) / Este trabalho analisa e discute o comportamento de blocos de fundação para estruturas pré-fabricadas de concreto sobre duas estacas submetidos à ação de força centrada. Como ligação pilar-fundação utilizouse o cálice de fundação com interface rugosa. O Modelo de Bielas e Tirantes é utilizado para modelar a transmissão de esforços do pilar para as estacas e a avaliação experimental verifica a validade desses modelos. A investigação experimental dos blocos teve como objetivo observar a colaboração do comprimento de embutimento do pilar para o dimensionamento da base do bloco e as diferenças na formação dos campos e trajetórias de tensões. Foram ensaiados três blocos em escala 1:2 sendo três alturas de colarinho diferentes. Para a instrumentação utilizou-se extensômetros elétricos posicionados nas armaduras principais de tração no bloco e na armadura principal do pilar e transdutores de deslocamento posicionados nas faces do bloco. Para o dimensionamento dos modelos foram seguidas as recomendações sugeridas por MELO (2004) assim como as indicações contidas na NBR 6118 (2003) e NBR 9062 (1985). Em função dos resultados obtidos por meio da análise experimental fica claro que não é necessário se considerar a altura de 2/3 do comprimento de embutimento do pilar para a transferência das forças por atrito, no caso específico de ação de força centrada, limite esse indicado por MELLO (2004). A partir dessas conclusões se torna possível desenvolver modelos de bielas e tirantes mais apropriados a esse tipo de bloco sobre duas estacas.

This work analyses and discusses the pile caps behavior for concrete
precast structures on two piles submitted to the action of centered force. As column-foundation connection, rough interface foundation socket was used. The strut-and-tie model is used to shape the effort transmission from the column to the pile-caps, confirmed by the experimental analyses. This investigation observed the cooperation of the column embendding for the pile caps basis design and the differences in the formation of regions and trajectories of stress. In the procedure, there were three 1:2 scale pile caps, in three different heights of pedestal walls. For the instrumentalization were used strain gages positioned on the principal stress reinforcement, on the pile caps and on the principal reinforcement column. LVDT´s were ositioned on the surface of the pile caps, also. For the models design were followed the indications from MELO (2004) as well as the indications from the rules NBR 6118 (2003) and NBR 9062 (1985). The obtained results from the experimental analyses show that it is not necessary to consider the 2/3 embendding length height of the pile caps for the friction forces transference, in case of load centered action, indicated by MELO (2004). As a conclusion, it is possible to develop strut-and-tie models appropriated to two pile caps.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufsc.br:123456789/90822
Date January 2007
CreatorsCampos, Leonardo Alves de
ContributorsUniversidade Federal de Santa Catarina, Marcellino, Narbal Ataliba
PublisherFlorianópolis, SC
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatvii, 150 f.| il., grafs., tabs.
Sourcereponame:Repositório Institucional da UFSC, instname:Universidade Federal de Santa Catarina, instacron:UFSC
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0019 seconds