Return to search

Resistência de três tipos de fixação utilizados no tratamento das fraturas do ângulo mandibular / Resistance of three types of fixation in the treatment of fractures of the mandibular angle

Orientadores: Alexandre Elias Trivellato, Marcio de Moraes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T07:03:24Z (GMT). No. of bitstreams: 1
Cavalieri-Pereira_Lucas_D.pdf: 1578055 bytes, checksum: 8c7fc995f3dac6a8d0d45c1bc49f3175 (MD5)
Previous issue date: 2012 / Resumo: Fraturas do ângulo mandibular são muito freqüentes dentre as fraturas mandibulares e um das formas de tratamento é a utilização de fixação interna com placas e parafusos. Neste estudo o objetivo foi avaliar comparativamente a resistência de três tipos de fixação em réplicas de mandíbula de poliuretano, empregando-se a técnica de Champy. Foram utilizadas 63 mandíbulas dentadas, submetidas aa seccionamento simulando uma fratura linear e favorável de ângulo mandibular esquerdo. As fixações foram realizadas com placas retas do sistema 2,0 mm, dispostas da seguinte forma: uma placa com quatro furos, uma com cinco furos e uma com quatro furos e extensão (ponte). A estabilização e fixação foram realizadas com adaptação da placa e quatro parafusos de 6,0 mm de comprimento, sobre a linha oblíqua da mandíbula. Foram elaborados 9 grupos, com 7 mandíbulas cada um, sendo 3 grupos fixados com placa de 5 furos, 3 com placa reta de 4 furos com extensão e 3 com placa reta de 4 furos. Cada conjunto foi submetido ao teste de carregamento linear com aplicação de carga no sentido súpero-inferior em três pontos distintos da mandíbula, de modo não simultâneo (região de molar ipsilateral à secção, incisivos centrais e molar contralateral) em máquina de ensaio universal EMIC DL 2000. Foram mensurados valores de carga no deslocamento de 1 mm, 2 mm e final e anotado o deslocamento final. Os resultados obtidos foram submetidos à análise estatística, utilizando a análise de variância (ANOVA), seguido do teste de Tukey, nível de significância de 5%. Nos valores de cargas obtidos, tanto quando aplicada no molar ipsilateral ao seccionamento, no molar contralateral ao seccionamento e entre incisivos centrais, foi verificada diferença estatística somente no momento do deslocamento final, na qual a placa com 5 furos e com 4 com extensão foi superior a placa com quatro furos. Não houve diferença entre placa com 5 furos e com 4 com extensão / Abstract: Mandibular angle fractures are very frequent among the mandibular fractures and a form of treatment is the use of internal fixation with plates and screws. In this study, the objective was to evaluate the resistance of three types of fixation in mandibular replicas of polyurethane, using the technique of Champy. Sixty three toothed mandibles were used, subject to sectioning simulating a linear and favorable fracture of left mandibular angle. The fixations were performed with straight plates system 2.0 mm, prepared as follows: one plate with 4-holes, one with 5-holes and one 4-holes and extension (bridge). Stabilization and adjustment were performed with locking plate and four screws of 6.0 mm in length, about the oblique line of the mandible. Nine groups were elaborated, with 7 each, which 3 groups being fixed with 5-holes plates, 3 groups with 4-holes plates with extension and 3 groups with 4-holes plates. Each set was submitted for loading test with load application towards in three distinct points of the mandible, so do not simultaneously (molar region on the side ipsilateral of section, the central incisors and contralateral molar) in universal testing machine EMIC DL 2000. Load values were measured at offset 1 mm, 2 mm and final and was noted the final dislocation. The results were submitted to statistical analysis, using analysis of variance (ANOVA) followed by Tukey test, a significance level of 5%. The values obtained, when loads were applied in the ipsilateral molar, contralateral molar and incisors, was verified statistically only at the final dislocation, in which the 5-holes plates and 4-holes with extension was more resistant than 4-holes plates. There was no difference between plate with 5-holes and 4-holes with extension / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/287857
Date08 January 2012
CreatorsCavalieri-Pereira, Lucas, 1982-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Moraes, Marcio de, 1966-, Trivellato, Alexandre Elias, Albergaria-Barbosa, José Ricardo de, Filho, Valfrido Antonio Pereira, Sverzut, Cassio Edvard, Kluppel, Leandro Eduardo
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format49 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0032 seconds