Return to search

Réparation ou renforcement des poutres en béton armé corrodées ou non par l'insertion de joncs de carbone dans la surface du béton (NSM technique) : étude expérimentale et modélisation par éléments finis. / Strengthening of corroded reinforced concrete (RC) beams with near surface mounted (NSM) technique using carbon fiber polymer (CFRP) rods : an experimental and finite element (FE) modelling study

Cette thèse s’intéresse à l’efficacité des renforcements par matériaux composites à base de fibres carbone (CFRP : Carbon Fiber Reinforced Polymer) par la technique NSM (Near Surface Mounted ; réalisation d’engravures sur la surface du béton) pour requalifier les structures corrodées. Elle est composée d’une partie expérimentale et d’une partie modélisation par la méthode des Eléments Finis (EF). La technique NSM consiste à réaliser des engravures sur la surface du béton où sont insérés les joncs de carbone rendus adhérents par remplissage d’une résine époxy. Les éléments étudiés dans cette thèse sont des poutres en béton armé naturellement corrodées pendant 28 années d’exposition à un environnement salin. Dans cette thèse, nous nous intéressons aux modes de rupture et à la capacité portante à la fois : en flexion et à l’effort tranchant. Le degré de corrosion a été mesuré par la méthode de perte de masses locales après la fin des essais mécaniques sur les barres longitudinales ainsi que sur les cadres d’effort tranchant. La première partie présente les résultats expérimentaux obtenus sur une poutre corrodée et une poutre témoin réparée ou renforcée en flexion par un jonc de carbone de 6 mm de diamètre inséré dans la surface tendue par la technique NSM. Les essais ont pour objectif d’étudier la capacité portante, la flèche à la ruine, la rigidité en flexion et le mode de ruine des deux poutres afin de vérifier l’efficacité du renforcement ou de la réparation... La seconde partie présente les résultats expérimentaux obtenus sur des poutres courtes permettant de mettre en avant la résistance vis à vis de l’effort tranchant. A partir des poutres longues testées dans la première partie, deux poutres courtes corrodées et deux poutres courtes témoins sont extraites. Une poutre courte corrodée et une poutre témoin sont réparées ou renforcées en flexion et une poutre corrodée et une poutre témoin sont en plus réparées ou renforcées vis-à-vis à l’effort tranchant par des joncs de carbone de 6 mm de diamètre par la technique NSM. L’éventuel glissement des armatures longitudinales sur les appuis a été mesuré durant les essais de flexion 3 points. Les résultats expérimentaux montrent que la corrosion des armatures longitudinales et la corrosion des cadres d’effort tranchant n’affectent pas le mode de ruine et modifient très peu les capacités portantes. La réparation vis-à-vis de l’effort tranchant avec la technique NSM change le mode de ruine de la formation d’une fissure diagonale due au glissement des barres d’acier tendues, à la formation d’une large fissure de flexion à mi-travée suivie de l’écrasement du béton comprimé... La troisième partie s’intéresse à la modélisation par la méthode de modélisation par EF du comportement global en flexion. Une première approche 2D est élaborée avec le code FEMIX développé à l’Université de Minho par le professeur Barros. Cinq poutres sont modélisées : 3 corrodées dont une réparée par la technique NSM et 2 témoins dont une renforcée par la technique NSM. La modélisation par EF donne de bons résultats sauf dans le cas de la poutre corrodée réparée dont le mode de ruine est non conventionnel (séparation du béton d’enrobage)... La quatrième et dernière partie est consacrée à l’étude numérique des poutres courtes. Quatre poutres sont modélisées : 2 corrodées réparées dont une réparée vis-à-vis de l’effort tranchant et 2 témoins renforcées dont une renforcée vis-à-vis de l’effort tranchant. La modélisation par EF est faite en 3D en utilisant le code FEMIX. Les résultats numériques reproduisent correctement les aspects importants du comportement force-flèche ainsi que les modes de fissuration à la ruine pour les poutres réparées vis-à-vis de l’effort tranchant ou non. / The thesis is composed of an experimental and Finite Element Modeling (FEM) study, investigating the effectiveness of the (Near Surface Mounted CFRP rods technique (NSM)) on the corroded RC beams. In the NSM technique, the CFRP rods are placed inside pre-cut grooves and are bonded to the concrete with epoxy adhesive. The thesis studies the failure modes and the mechanical performance of the corroded RC beams due to steel corrosion and finally, the prediction of the mechanical behaviour of the repaired corroded RC beams using nonlinear models based on FE numerical modelling. The corroded RC beams studied here in this study were exposed to natural corrosion for more than 28 years. The first part includes experimental results which were obtained on two beams: (one corroded and one control beams, both are 3 metres long) repaired or strengthened in bending with one 6-mm-diameter NSM CFRP rod. The beams were tested in a three-point bending test up to failure. Overall stiffness was studied. Ultimate capacity, ductility and failure modes were also reviewed. Finally some comparisons were made between repaired and non-repaired beams in order to assess the effectiveness of the NSM technique... The second part discusses the experimental results of two short corroded beams, which were tested under three-point bending until failure, along with two short control beams of the same characteristics (age, length and cross-section). One RC corroded deep beam was repaired in bending and the other one was repaired in both bending and shear with NSM CFRP rods. After the beams had been tested up to failure, the main steel bars and the stirrups were extracted from the beams and the loss of mass was measured and plotted for both the longitudinal and transverse reinforcement. The slip of tensile reinforcement at the end of the beams was also measured during the tests. The effect of corrosion and the effect of repairing with CFRP NSM rods in bending and shear on the behaviour of deep beams are discussed. Experimental results showed that both corroded and control deep beams repaired only in bending failed due to shear failure mode(diagonal tension failure), while corroded and control beams repaired in both bending and shear failed due to concrete crushing. The test results also showed that the corrosion of both longitudinal and transversal reinforcement hardly modified the mechanical response of deep beams... The third part shows experimental results and numerical modelling results of 2D finite element model using the FEMIX computer code were obtained on five, 3-metre-long beams: three corroded RC beams and two control beams. Two beams, one corroded and one control were repaired or strengthened in bending with NSM CFRP rod and were then tested in three-point bending up to failure. The FE numerical modelling results from FEMIX were compatible with the experimental ones except for the repaired corroded beam, for which a three-dimensional model using the commercial software ABAQUS was required... Finally, the last part presents 3D numerical modelling results in terms of load-deflection curves, and failure modes for 4 short corroded beams: two corroded beams and two control beams, half of the beams were let repaired or strengthened in bending only with NSM CFRP rods while the others were repaired or strengthened in both bending and shear with NSM technique. Results showed that the FE model was able to capture the main aspects of the experimental load-deflection curves of the RC beams, moreover it has presented the experimental failure modes and FE numerical modelling crack patterns and both gave similar results for both shear-repaired and non-shear repaired beams, three dimensional crack patterns were produced for shear-repaired beams in order to investigate the splitting cracks occurred at the middle of the beams and near the support.

Identiferoai:union.ndltd.org:theses.fr/2015ISAT0009
Date04 June 2015
CreatorsAlmassri, Belal
ContributorsToulouse, INSA, Al Mahmoud, Firas, François, Raoul
Source SetsDépôt national des thèses électroniques françaises
LanguageEnglish
Detected LanguageFrench
TypeElectronic Thesis or Dissertation, Text

Page generated in 0.0086 seconds