Return to search

Desenvolvimento de sistema de supervis?o para um duto de testes de PIGs

Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-02-02T14:03:32Z
No. of bitstreams: 1
VictorCarvalhoGalvaoDeFreitas_DISSERT.pdf: 9256729 bytes, checksum: 2b7fb909aa180b8bef8f5de69a706540 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-02-08T20:20:54Z (GMT) No. of bitstreams: 1
VictorCarvalhoGalvaoDeFreitas_DISSERT.pdf: 9256729 bytes, checksum: 2b7fb909aa180b8bef8f5de69a706540 (MD5) / Made available in DSpace on 2017-02-08T20:20:54Z (GMT). No. of bitstreams: 1
VictorCarvalhoGalvaoDeFreitas_DISSERT.pdf: 9256729 bytes, checksum: 2b7fb909aa180b8bef8f5de69a706540 (MD5)
Previous issue date: 2016-09-30 / Diversas ferramentas de manuten??o t?m sido empregadas para garantir o correto funcionamento da malha dutovi?ria de transporte de petr?leo, g?s natural e derivados, devido ao importante papel que ela desempenha na cadeia de abastecimento e distribui??o da ind?stria de energia. Entre essas ferramentas, podemos destacar o uso de PIGs (Pipeline Inspection Gauge): dispositivos que viajam no interior dos dutos e s?o capazes de realizar desde uma simples limpeza at? uma inspe??o detalhada de integridade da tubula??o. Neste trabalho, desenvolvemos um sistema de medi??o e supervis?o para um duto de testes cujo principal objetivo ? pesquisar t?cnicas de controle de velocidade para PIGs. Usamos transdutores de press?o ao longo do duto a fim de determinar a posi??o e a velocidade m?dia do PIG. O sistema de supervis?o foi implementado no Elipse SCADA, respons?vel pela visualiza??o e registro de vari?veis do sistema. A interface entre esse sistema e os transdutores foi realizada por meio de um CLP. Os resultados obtidos demonstram que o deslocamento do PIG afeta significativamente o comportamento da press?o no duto e, assim, podem ser usados para estimar a posi??o e a velocidade m?dia do dispositivo por meio dos sensores utilizados. / Several maintenance tools have been employed to ensure the correct operation of the
pipeline network to transport oil and gas, due to the important role it plays in the chain
of supply and distribution of the energy industry. Among these tools, we can highlight the
use of PIG (Pipeline Inspection Gauge) ? a device that travels inside the pipeline and is
capable of performing from a simple cleaning to a detailed inspection of pipe integrity. In
this work, we developed a measurement and monitoring system for a test pipeline whose
main objective is to research PIG speed control techniques. We use pressure transducers
along the pipeline in order to determine the position and the average speed of PIG.
The supervisory system was implemented in Elipse SCADA, responsible for viewing and
recording system variables. The interface between this system and the transducers was
done using a Programmable Logic Controller. The results show that displacement of the
PIG significantly affects the behavior of the pressure in the pipeline and thus can be used
to estimate the position and the average speed of the device by means of the sensors used.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufrn.br:123456789/21910
Date30 September 2016
CreatorsFreitas, Victor Carvalho Galv?o de
Contributors51618362968, Maitelli, Andr? Laurindo, 42046637100, Gabriel Filho, Oscar, 11376040697, Salazar, Andres Ortiz
PublisherPROGRAMA DE P?S-GRADUA??O EM CI?NCIA E ENGENHARIA DE PETR?LEO, UFRN, Brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFRN, instname:Universidade Federal do Rio Grande do Norte, instacron:UFRN
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0013 seconds