Return to search

Estimulação multidirecional de celulas cardiacas : instrumentação e experimentação / Multidirectional stimulation of cardiac cells : instrumentation and experimentation

Orientadores: Jose Wilson Magalhaes Bassani, Rosana Almada Bassani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-15T01:38:31Z (GMT). No. of bitstreams: 1
Fonseca_AlexandraValenzuelaSantelicesda_M.pdf: 1311974 bytes, checksum: ab061a6f8d63a1175d6a3c9281e0704e (MD5)
Previous issue date: 2009 / Resumo: O procedimento mais efetivo para reverter arritmias cardíacas consiste na aplicação de choques elétricos de alta intensidade, como e o caso da desfibrilação. Estimulação com campos elétricos (E) elevados, entretanto, exerce efeitos deletérios sobre o músculo cardíaco, podendo causar disfunções elétrica e contrátil e até a morte celular. Privilegiar a estimulação na direção longitudinal, para qual o limiar de excitação das células cardíacas e menor, seria uma forma de se reduzir a amplitude do estimulo sem perder a efetividade da estimulação. Para isto, foi desenvolvido e testado, em miócitos ventriculares orientados de maneira aleatória, um sistema de estimulação multidirecional automática que permite o chaveamento controlado de estímulos sequênciais para três diferentes pares de eletrodos (cada um correspondendo a uma direção) em um intervalo de tempo inferior a duração do potencial de ação (período em que a célula se encontra eletricamente refrataria). A estimulação multidirecional com uma intensidade de E 20% acima do limiar estimulatório (1,2× ETM) dobrou o recrutamento (excitação) de células (80 vs. 40% com estimulação unidirecional, p<0,001). Adicionalmente, o recrutamento com a estimulação multidirecional automática foi maior (p< 0,001) do que a soma dos recrutamentos obtidos com a estimulação em cada direção individualmente (sem intersecção), o que sugere que a estimulação sublimiar durante o procedimento automático pode aumentar a excitabilidade celular. Foi observado também que, para uma dada amplitude do estimulo, o uso da forma de onda bipolar (para a qual o valor de ETM foi menor que para pulsos monopolares: 3,2 ± 0,1 vs. 3,9 ± 0,1 V/cm; p< 0,001) promoveu um recrutamento maior do que com o pulso monopolar (recrutamento de 50% das células foi obtido com 2,97 ± 0,04 e 4,18 ± 0,05 V/cm para pulsos bipolares e monopolares, respectivamente; p< 0,05). A combinação da estimulação multidirecional automática com o uso da forma de onda bipolar permitiu, portanto, uma redução de cerca de 50% no valor do E absoluto (3,8 vs. 7,8 V/cm com estimulação unidirecional e pulso monopolar) para um recrutamento de ~80% das células. A aplicação destes procedimentos na
estimulação cardíaca (marcapasso e desfibrilação) pode otimizar o processo, levando a uma melhor eficiência e uma menor incidência de lesão. / Abstract: The most effective procedure to revert cardiac arrhythmias consists in the application of high intensity electric discharge, such as in cardiac defibrillation. Nevertheless, stimulation using high electric fields (E) may cause injury to the cardiac muscle, generating electric and contractile dysfunctions and even cell death. A possible way to reduce the stimulus intensity while maintaining the stimulation effectiveness would be stimulate cardiac cells with E applied parallel to the cell major axis, in which case the stimulation threshold is lower. To test this possibility, a multidirectional stimulation system was developed and tested on randomly-oriented rat ventricular myocytes. The system allows the controlled switching of sequential stimuli delivered to three different pairs of electrodes (each one corresponding to one direction), in a period shorter than the action potential duration (when cell is electrically refractory). The multidirectional stimulation with E intensity 20% above the stimulation threshold (1.2× ETM) doubled the percentage of recruited (excited) cells (~80 vs. ~40 % with unidirectional stimulation, p<0.001). Additionally, recruitment with automatic multidirectional stimulation was greater (p< 0.001) than the sum of recruitments obtained from stimulation of each direction individually (without intersection), which is suggestive that subthreshold stimulation during the automatic procedure might enhance cell excitability. Moreover, it was observed that for a given absolute stimulus amplitude, the use of biphasic waveforms (for which ETM was lower than for monophasic pulses: 3.2 ± 0.1 vs. 3.9 ± 0.1 V/cm; p< 0.001) promoted higher recruitment than monophasic stimuli (50% recruitment was attained with 2.97 ± 0.04 and 4.18 ± 0.05 V/cm with biphasic and monophasic pulses, respectively; p< 0.05). Thus, the association of automatic multidirectional stimulation and biphasic waveform enabled a 50% reduction of the absolute E value (3.8 vs. 7.8 V/cm with unidirectional stimulation and monopolar pulse) to evoke excitation in ~80% of the cells. The application of these procedures to cardiac stimulation (pacemaker and defibrillation) might optimize the process, leading to greater efficiency and lower injury incidence. / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/259396
Date12 March 2009
CreatorsFonseca, Alexandra Valenzuela Santelices da
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Bassani, Rosana Almada, 1955-, Bassani, José Wilson Magalhães, 1953-, Junior, Wilson Nadruz, Costa, Eduardo Tavares
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format70 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0029 seconds