Return to search

Avaliação e caracterização de sistemas baseados em ponto nuvem visando a remoção de albumina do plasma sanguineo / Evaluation and characterization of cloud point based systems for albumin removal from blood plasma

Orientador: Marco Aurelio Zezzi Arruda / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-10T13:14:37Z (GMT). No. of bitstreams: 1
Silva_MarceloAnselmoOseasda_M.pdf: 1369513 bytes, checksum: 35e33836144e52420b1164f512aa97e9 (MD5)
Previous issue date: 2008 / Resumo: Nesta dissertação foi estudado o comportamento de partição da albumina, proteína presente em elevada concentração no plasma sangüíneo e que interfere na determinação em diversas técnicas analíticas. No estudo efetuado foram avaliados diferentes sistemas aquosos de duas fases, explorando um fenômeno denominado ponto nuvem. Tais sistemas empregam surfactantes, sob condições experimentais específicas, obtendo-se a formação de duas fases imiscíveis: uma rica e outra pobre em tensoativo. Observou-se que devido às características hidrofílicas da albumina, bem como à dimensão dos agregados formados, sua extração para fase rica em tensoativo apresenta valores de coeficiente de partição que não ultrapassam 0,66 o que representa uma eficiência de extração de ca.40%. A extração da proteína apresentou-se viável mediante a utilização de uma mistura composta por um tensoativo não-iônico (Triton® X-114), que possibilita a separação de fases em temperatura biocompatível, na presença de outro tensoativo iônico (dodecil sulfato de sódio - SDS), que atua favorecendo as interações eletrostáticas entre os agregados e as moléculas protéicas, desde que se trabalhe em meio com pH abaixo de 5,0. Análises de dicroísmo circular complementaram o estudo e fornecerem evidências de que a aplicação do sistema baseado na mistura composta por Triton® X-114 e SDS causava desnaturação parcial da proteína, o que não inviabilizou sua aplicação para extração da mesma em uma amostra real. A eficiência deste sistema foi, então, avaliada para a remoção de albumina em plasma sangüíneo. Um coeficiente de partição de 1,1 foi obtido, indicando que ca.51% das proteínas encontravam-se na fase rica em tensoativo. As amostras submetidas ao procedimento de extração também foram avaliadas frente à técnica de eletroforese em gel, sendo que a fase pobre em sufactante apresentou um perfil eletroforético mais detalhado quando comparada a uma amostra que não foi submetida ao procedimento proposto. Já na fase rica em surfactante, foi observada a presença majoritária de albumina e, em menor concentração, outras proteínas de grande abundância no plasma tais como imunoglobulina G e transferrina. Por fim, o método apresentou desempenho semelhante ao de sistemas disponíveis comercialmente para remoção de albumina, tal como o sistema da Millipore®, apresentado neste trabalho / Abstract: In this work the partition behavior of albumin was studied, which is found at high concentrations in blood plasma, which interferes in many analytical techniques determinations. The present study evaluated different aqueous two-phase systems, exploiting a phenomenon called of cloud point. These systems employ surfactants under specific experimental conditions, enabling formation of two immiscible phases: one rich and another poor in surfactant. Due to the hydrophilic characteristcs of albumin, as well as its aggregate dimensions, its extration to the surfactant rich phase presented partition coefficients lower than 0.66, representing and extraction efficiency of ca. 40%. Protein extraction was feasible by applying a mixture comprised of a nonionic surfactant (Triton® X-114), which allowed the phase separation at biocompatible temperatures, and an ionic one (sodium dodecylsufate - SDS), wich promotes eletrostatic interactions between aggregates and protein molecules, since the extraction procedure is carried out at pH 5.0. Circular dichroism analysis complemented the study and it showed that a system based on a Triton® X-114 and SDS mixture causes partial protein denaturation, but its application for a real sample is feasible. The efficiency of this was evaluated for albumin removal from blood plasma. A partition coefficient of 1.1 was obtained, indicating that ca. 51% of proteins were contained in the surfactant rich phase. Albumin depleted samples were submitted to gel eletrophoresis and the surfactant poor phase presented a more detailed gel electrophoresis profile, when compared with a crude sample. The surfactant rich phase reveled that albumin is the predominant protein present, but it is possible to find other highly concentrated plasmatic proteins including immunoglobulin G and transferrin. Finally, the method presented similar performance when compared with commercially available systems for albumin removal, such as the Millipore® system, wich was also evaluated in this work / Mestrado / Quimica Analitica / Mestre em Química

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/248577
Date25 February 2008
CreatorsSilva, Marcelo Anselmo Oseas da, 1982-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Arruda, Marco Aurelio Zezzi, 1965-, Rosias, Maria Fernanda Georgina Gine, Kubota, Lauro Tatsuo
Publisher[s.n.], Universidade Estadual de Campinas. Instituto de Química, Programa de Pós-Graduação em Química
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format113p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds