• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • Tagged with
  • 31
  • 31
  • 25
  • 25
  • 25
  • 20
  • 19
  • 10
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Otimização de metodologia para determinação de molibdênio / Optimize of methodology of extraction and determination of molybdenum in soils

Andrade, Carlos Eduardo Oliveira 28 February 2005 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-10-05T17:02:44Z No. of bitstreams: 1 texto completo.pdf: 205064 bytes, checksum: a10319acb7df6610f6c87215a892e994 (MD5) / Made available in DSpace on 2016-10-05T17:02:44Z (GMT). No. of bitstreams: 1 texto completo.pdf: 205064 bytes, checksum: a10319acb7df6610f6c87215a892e994 (MD5) Previous issue date: 2005-02-28 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Foi desenvolvido um procedimento para a determinação espectrofotométrica de molibdênio, usando a técnica de extração ponto nuvem. Nesta técnica o complexo de molibdênio com tiocianato, em meio ácido, e na presença de um agente redutor é extraído pelo surfactante Triton X-100 ou X- 114. A separação de fases se dá por aquecimento acima de uma temperatura crítica em que ocorre a turvação da solução e por isso essa técnica recebe o nome de “separação ponto nuvem”, do inglês “Cloud point”. Neste processo são formadas duas fases isotrópicas, uma delas aquosa (ou fase pobre em surfactante) e a outra fase rica em surfactante, onde se encontra a espécie a ser extraída. O fenômeno é reversível, e sob resfriamento, uma única fase é novamente obtida. Umas das principais características da reação entre o molibdênio e tiocianato é o estado de oxidação do molibdênio que deve estar em V para que ele possa formar um complexo sem carga com o tiocianato, com isto a necessidade de no meio reacional haver a presença de um agente redutor, que possa fazer a redução do molibdênio de VI à V. Dentre os agentes redutores estudados ácido ascórbico 1,0% (m/v), cloridrato de hidroxilamina 1,0 % (m/v) e zinco em pó (0,10 g), o cloridrato de hidroxilamina e o zinco em pó foram os que apresentaram melhores resultados. A solução de cloridrato de hidroxilamina 1,0 % (m/v) apresentou algumas vantagens em relação ao zinco em pó. O zinco, além de reagir com o íon molibdato, reage também com o íon H3O+, podendo ser todo consumido por este íon acarretando o problema da reoxidação de Fe2+ a Fe3+ que é um interferente potencial. Por outro lado o cloridrato de hidroxilamina não é oxidado pelo íon H3O+, e neste caso, permanece na solução durante todo o processo, além disso o zinco em pó permanece insolúvel. Vários níveis de concentração dos surfactantes triton X- 100 e triton X-114 foram estudados, observando-se que as concentrações dos surfactantes que produziram melhores resultados foram 2,0 % (m/v) para o triton X-100 e 1,0 % (m/v) para o triton X-114. O complexo apresenta banda espectral na região da luz visível com uma absorção máxima em 470 nm na presença do triton X-100 e 490 nm na presença do triton X-114. O Triton X-114 foi escolhido para extração do molibdênio, pois na utilização do Triton X-100 ocorreu o inconveniente da formação de HCN no meio que é um gás altamente tóxico, comprovado pelo ensaio do azul-da-prússia, o mesmo não se verificou quando da utilização do Triton X-114, além disso a temperatura em que ocorre a separação de fases para o triton X-100 é muito elevada. Os efeitos dos reagentes NH4SCN, H3NOHCl e HCl sobre a resposta, absorvância, e as relações entre eles foram estudadas utilizando um planejamento fatorial 23. Com isso foi possível chegar às concentrações de 0,1 mol L-1 de NH4SCN , 0,5 % (m/v) de H3NOHCl e 1,0 % (v/v) de HCl que otimizam a determinação de molibdênio com tiocianato. Foi estudado a interferência das espécies Cr6+ e Fe3+, constatando que o Fe3+ é sério interferente, pois reage com o íon SCN- formando um complexo vermelho e o Cr6+ não apresentou interferência dentro da faixa estudada. Foi utilizada uma resina de troca catiônica para eliminar a interferência do Fe3+ constatando que todo o ferro foi retido na resina para uma concentração de até 100 vezes maior que a concentração do molibdênio estudada. O procedimento foi usado na determinação de molibdênio em duas amostras de solos da região de Sete Lagoas – MG, onde os resultados mostraram uma concentração de 3,29 ± 0,06 μg g-1 no latossolo vermelho e no latossolo vermelho amarelo não foi detectado a presença de molibdênio. Os resultados mostraram que o método é bastante preciso, pois o teor de molibdênio determinado pelo método proposto se aproximou do encontrado por absorção atômica de 3,42 ± 0,04 μg g-1 na amostra de latossolo vermelho. Este método tornou-se menos trabalhoso uma vez que não é necessária a utilização da extração com solventes orgânicos. / A procedure was developed for spectrophotometric determination of molybdenum, using the extraction technique of cloud point. In this technique the molybdenum complex with thiocyanate in acid solution and in the presence of a reducing agent Triton X-100 or X-114 is extracted by the surfactant. The separation of phases is given with the heating at an above critical temperature where the turbidity of the solution occurs and therefore this technique is named "cloud point separation". In this process, two isotropic phases are formed, one of them in aqueous solution, poor in surfactant, contrasting to the other, rich in surfactant, where the species to be extracted are found. The phenomenon is reversible and an unique phase is obtained again at low temperatures. One of the main characteristics of the reaction between the molybdenum and thiocyanate is the oxidation condition of the molybdenum that should be in V so that it can form a compound without load to the thiocyanate, that ́s why it is made necessary the presence of a reducing agent in the reaction, to reduce the molybdenum from VI to V. Among the reducing agents studied, ascorbic acid 1.0% (w/v), hydroxylamine chloride 1.0% (w/v) and zinc powder (0.10g), the hydroxylamine chloride and zinc powder were the ones that presented better results, but the hydroxylamine chloride 1.0% (w/v) solution showed some advantages in comparison to the zinc powder. The zinc powder, besides reacting with the molybdate ion, also reacts with the H3O+ ion and might be consumed by this ion leading to the problem of reoxidation of Fe3+, a potential interference. The hydroxylamine chloride is not rusted by the H3O+ ion and in this case, it stays in solution during the whole process. Above all, the zinc powder does not dissolve remaining insoluble. Several level of triton X-100 and triton X-114 concentration were studied, and was observed that the best results was those where the surfactant concentration was 2.0% (w/v) for the triton X- 100 and 1.0% (w/v) for the triton X-114. The complex shows a spectrum band in the UV-visible region with maximum absorbtion in 470o nm in the presence of triton X-100 and 490o nm, in triton X-114. The triton X-114 was chosen for the molybdenum extraction because with Triton X-100 was the inconvenience of the HCN formed which is a highly poisonous gas, identified by the Prussian blue test; the same didn ́t happen when Triton X-100 was used. On the other hand the phase separation for triton X-100 occurs at a very high temperature. The effects of the reagentes NH4SCN, H3NOHCl and HCl about the answer, absorbtion and the relationships among them were studied using a factorial planning 23. With that it was possible to get to the concentrations of 0.1 mol L-1 of NH4SCN, 0.5% (m/v) of H3NOHCl and 1.0% (v/v) of HCl that optimizes the molybdenum determination with thiocyanate. The interference study on the species Cr6+ and Fe3+ has shown that Fe3+ interfers seriously by reacting with the SCN- ion forming a red complex, while Cr6+ did not interfer within the range studied. A resin of cation exchanging was used to eliminate the interference of Fe3+. It was observed that the latter species was kept in the resin for a concentration up to 100 times higher than the one used for molybdenum in this work. The procedure was carried out in two soil samples from Sete Lagoas - MG in order to identify the molybdenum. The results have shown a concentration of 3.29 ± 0.055 mg g-1 from the red latossol. The molybdenum was not detected in the red yellow latossol. The results showed that the method is quite necessary because the concept of certain molybdenum determination by the proposed method approximated to the found by atomic absorbtion of 3.42 ± 0.04 mg g-1 in the sample of red latossol. This method became less difficult, once it is not necessary extraction with organic solvents. / Não foi localizado o cpf do autor.
2

Extração e fracionamento de proteinas de plasma sanguineo baseada no procedimento do ponto nuvem / Extration and fractionation of blood plasma proteins based on cloud point procedure

Lopes, Aline Soriano 15 July 2005 (has links)
Orientador: Marco Aurelio Zezzi Arruda / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-04T22:51:49Z (GMT). No. of bitstreams: 1 Lopes_AlineSoriano_M.pdf: 3574562 bytes, checksum: 6e7d02685ed814950db0ef3f76b933c4 (MD5) Previous issue date: 2005 / Mestrado / Quimica Analitica / Mestre em Química
3

Pre-concentração por electrostacking e por ponto nuvem para determinação de arsenio e cadmio em amostras ambientais e biologicas / Pre-concentration by electrostacking and by cloud point for determination of metallic ions in environmental and biological samples

Coelho, Luciana Melo 17 June 2005 (has links)
Orientador: Marco Aurelio Zezzi Arruda / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-04T21:48:44Z (GMT). No. of bitstreams: 1 Coelho_LucianaMelo_D.pdf: 3258414 bytes, checksum: bf5794c1897da59a91597510c34ed02a (MD5) Previous issue date: 2005 / Doutorado / Quimica Analitica / Doutor em Quimica
4

Aplicação de extração em ponto nuvem com di-2-piridil cetona saliciloilhidrazona visando à determinação de íons metálicos

Garcia, Samara January 2013 (has links)
Orientador: Ivanise Gaubeur / Tese (doutorado) - Universidade Federal do ABC. Programa de Pós-Graduação em Ciência e Tecnologia/Química, 2013.
5

Desenvolvimento de procedimentos limpos para extração de íons metálicos em ponto nuvem / Development of green analytical procedures for cloud-point extraction of metal ions

Silva, Sidnei Gonçalves da 28 February 2008 (has links)
O presente trabalho enfoca o desenvolvimento de procedimentos analíticos limpos através da extração e pré-concentração de íons metálicos em ponto nuvem para aumento de sensibilidade, melhoria de seletividade e substituição de solventes tóxicos. Cobre(II), ferro(II) e níquel(II) foram extraídos simultaneamente em digeridos de materiais vegetais, utilizando como agente extrator o Triton X-114, após formarem complexos hidrofóbicos com o 1,2-tiazolilazo-2-naftol (TAN). Os analitos foram determinados por espectrometria de absorção atômica com chama (Cu, Fe e Ni) ou por espectrofotometria de absorção molecular (Fe). A determinação de Cu e Ni por espectrofotometria de absorção molecular foi inviabilizada por interferências espectrais causadas pela formação de complexos com diversos íons metálicos encontrados nos digeridos dos materiais vegetais. Nas medidas por FAAS, os limites de detecção (99,7 % de confiança) foram estimados em 1,10 e 5 µg L-1 para cobre, ferro e níquel, respectivamente. Respostas lineares foram observadas para cobre e ferro na faixa de concentração de 25-200 µg L-1 e para o níquel entre 5 e 80 µg L-1 . O fator de enriquecimento foi estimado em 30 e a extração dos analitos foi quantitativa, de acordo com medidas efetuadas no sobrenadante após extração. Na determinação de ferro por espectrofotometria de absorção molecular, o limite de detecção foi estimado em 1 µg L-1 , com resposta linear entre 6 e 60 µg L-1 e fator de enriquecimento estimado em 20. Após digestão com ácidos diluídos em forno de microondas, o procedimento proposto foi aplicado à determinação dos analitos em digeridos de materiais de referência certificados, sendo os resultados concordantes com os valores certificados a nível de confiança de 95 %. O consumo de reagentes foi estimado em 50 mg Triton X-114 e 150 µg TAN por determinação. / This work is focused on the development of green analytical procedures for cloud-point extraction and concentration of metal ions, aiming increasing sensitivity, improving selectivity and avoiding the use of toxic solvents. Copper(II), iron(II) and nickel(II) were simultaneously extracted from plant materials digests, by using Triton X-114 as extracting agent, after formation of hydrophobic complexes with 1,2- tiazolylazo-2-naphthol (TAN). The analytes were determined by flame atomic absorption spectrometry (Cu, Fe and Ni) or by molecular absorption spectrophotometry (Fe). The determination of Cu and Ni by UV-vis spectrophotometry was hindered by spectral interferences caused by the formation of complexes with several metal ions in the sample digests. In the measurements by FAAS, the detection limits (99.7 % confidence level) were estimated as 1, 10 and 5 µg L-1 for copper, iron and nickel, respectively. Linear responses were observed in the 25-200 µg L-1 range for copper and iron and 5-80 µg L-1 for nickel. The enrichment factor was estimated as 30 and the extraction was quantitative, as evaluated by measurements in the supernatant solution after extraction. For iron determination by UV-vis spectrophotometry, the detection limit was estimated as 1 µg L-1 , with linear response within 6 and 60 µg L-1 and enrichment factor of 20. After digestion with diluted acids in microwave oven, the procedure was applied to the determination of the metals in reference materials and the results agreed with the certified values at the 95 % confidence level. The reagent consumption was estimated as 50 mg Triton X-114 and 150 µg TAN per determination.
6

Dissulfoton: avaliação da mobilidade e extração ponto nuvem / Disulfoton: evaluation of the mobility and cloud point extraction

Faria, Anízio Márcio de 18 July 2003 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-10-04T11:22:22Z No. of bitstreams: 1 texto completo.pdf: 2562929 bytes, checksum: 7bd846169c21752e1d29034853f56a15 (MD5) / Made available in DSpace on 2016-10-04T11:22:22Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2562929 bytes, checksum: 7bd846169c21752e1d29034853f56a15 (MD5) Previous issue date: 2003-07-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Foram conduzidos dois projetos distintos neste trabalho com o inseticida sistêmico organofosforado Dissulfoton. Na primeira série de experimentos, foi avaliada a possibilidade de contaminação de águas subterrâneas pelo Dissulfoton e seus produtos de degradação, avaliando a mobilidade do inseticida, na sua forma pura, em um latossolo vermelho-amarelo. Para tal, foram montados sistemas de percolação constituídos de 10 séries de colunas de 15 cm de altura, divididas em três camadas de 5 cm cada, preenchidas com solo. As colunas foram submetidas a simulações de eventos de chuva, por um período de 90 dias. A cada 10 dias, um evento de chuva era simulado e a mobilidade do Dissulfoton era avaliada pela quantificação do mesmo e de seus produtos de degradação em cada camada das colunas de solo e na água percolada. Técnicas de extração líquido-líquido e líquido-sólido, previamente otimizadas, foram empregadas para a extração do Dissulfoton das matrizes (água e solo). Após 90 dias de experimento, os resultados mostraram que o Dissulfoton foi detectado somente na camada superficial do solo, de 0 a 5 cm. Após a primeira simulação de chuva, o inseticida sofre degradação contínua até o 60o dia de experimento, a partir do qual o composto não é mais detectado no solo. Após esse período são encontrados apenas os produtos finais de sua rota de degradação, o Dissulfoton sulfona e seu análogo oxigenado. Estes compostos, ao contrário do Dissulfoton, são encontrados nas camadas mais profundas de solo, de 5 a 10 e 10 a 15 cm, e também na água percolada. A quantidade destes dois compostos aumenta continuamente, chegando a um total de 92 % da quantidade do Dissulfoton aplicada, no 90o dia de experimento. Quanto à água percolada, somente o Dissulfoton sulfona e seu análogo oxigenado foram detectados, em quantidades inferiores a 5 % da massa de Dissulfoton aplicada inicialmente. Conclui-se então, que a possibilidade de se encontrar o Dissulfoton em águas subterrâneas é pequena, devido a sua baixa mobilidade no solo e sua rápida degradação a outros compostos. Porém o Dissulfoton sulfona e seu análogo oxigenado são mais persistentes e apresentam alta mobilidade, aumentando a probabilidade de serem lixiviados ou percolados pelo solo e contaminar águas mais profundas. O uso de quantidades excessivas de solventes orgânicos, aliado a outros problemas relacionados com a extração líquido-líquido, tem limitado o emprego desta técnica. Tornou-se imprescindível, então, o desenvolvimento de metodologias alternativas de extração que possibilitem a redução destes problemas. Na segunda série de experimentos deste trabalho, foi desenvolvida uma metodologia de extração de Dissulfoton de águas, baseada nas características anfifílicas das moléculas de surfactantes. Esta técnica é conhecida como extração ponto nuvem (“cloud point extraction”). A técnica de extração do Dissulfoton em água consistiu em acrescentar a amostra aquosa contendo Dissulfoton, uma certa quantidade de surfactante. Em condições otimizadas, a mistura foi separada por centrifugação e a fase rica em surfactante separada para a análise. Para possibilitar as análises dos extratos por cromatografia gasosa, foi otimizado um sistema de “cleanup”, com colunas cromatográficas, para a remoção do surfactante, Triton X-114, do material extraído. Os adsorventes que proporcionaram os melhores resultados foram a sílica-gel e o Florisil, dispostos em duas colunas em série. A mistura de metanol:hexano (1:1) foi o eluente com que se obtiveram os melhores resultados. A quantidade de surfactante necessária para a extração do Dissulfoton foi avaliada e a que proporcionou maior percentagem de recuperação, acima de 90 %, foi uma solução de Triton X-114 a 1,0 % (m/v). Verificou-se, também, a influência de alguns fatores na eficiência da extração do Dissulfoton na água, tais como a variação do pH da amostra, o aumento da força iônica e a presença de outros surfactantes. A força iônica foi o fator de maior influência, aumentando a percentagem de recuperação do Dissulfoton para valores próximos de 100 %, enquanto que a presença de outros surfactantes, como o Triton X-100 e o SDS, reduziu a eficiência de extração do método. A metodologia de extração ponto nuvem do Dissulfoton de água, acoplada a um sistema de “cleanup”, composto de colunas de sílica-gel e Florisil, se mostrou, pelos parâmetros de validação avaliados, pelo menos, comparável ao método convencional, além de ser um método simples e de fácil execução. Devido à redução significativa do volume de solvente empregado, se mostrou também, econômica e ecologicamente viável. / In this work two distinct projects with the systemic organophosphorus insecticide Disulfoton have been carried out. In one series of experiments, the possibility of underground water contamination by Disulfoton and its products of degradation was evaluated, using the mobility of the insecticide, in its pure form, on a red-yellow latossolo. For such, percolation systems constituted of 10 series of columns of 15 cm of height were mounted, divided in three layers of 5 cm each, filled with soil. The columns were submitted to simulated rain events over a period of 90 days. Every 10 days, a rain event was simulated and the mobility of Disulfoton was evaluated for its quantification and that of its products of degradation, in each layer of the columns of soil and in the percolated water. Techniques of liquid-liquid and liquid-solid extraction, previously optimized, were employed for the extraction of the Dissulfotons from the matrices (water and soil). After 90 days of experiments, the results show that Disulfoton was only detected in the superficial layer of the soil, of 0 to 5 cm. After the first rain simulation, the insecticide suffers a continuous degradation until the 60th day of the experiment, after which the compound is no longer found in the soil layer. After this period only the last products of its route of degradation, Disulfoton sulfone and its oxygenated analog are found. These compounds, in contrast of Disulfoton, are found in the deepest soil layers, of 5 to 10 and 10 to 15 cm, and also in the percolated water. The mass of these two compounds increases continuously, arriving at a total of 92 % of the amount of Disulfoton applied, in 90th day of experiment. With respect to the percolated water, only the Disulfoton sulfone and its oxygenated analog were detected, in amounts inferior to 5 % of the mass of Disulfoton initially applied. It was concluded then, that the possibility to find Disulfoton in underground waters is small, due its low mobility in the soil and its fast degradation to other compounds. However, the Disulfoton sulfone and its oxygenated analog are more persistent and present high mobility, increasing their probability to be leached or percolated in the soil and to contaminate deeper waters. The use of large amounts of organic solvents, allied to other problems related with liquid-liquid extraction, has limited the use of this technique. It then became essential to develop alternative methodologies of extraction that make the reduction of these problems possible. In the other series of experiments of this work, a methodology of extraction of Disulfoton from waters was developed, based on the amphiphilic characteristics of surfactant molecules. This technique is known as cloud point extraction. The technique of extraction of Disulfoton in water consisted of adding to the aqueous sample containing Disulfoton a certain amount of surfactant. In optimized conditions, the mixture was separated by centrifugation and the surfactant-rich phase separated for the analyses. To make possible the analyses of extracts by gas chromatography, a system of "cleanup" with small chromatographic columns was optimized for the removal of the surfactant Triton X-114 from the extracted material. The adsorvents that provided the best results were silica-gel and Florisil, disposed in two columns in series. A methanol:hexane mixture (1:1) was the eluent that it got the best results. The amount of surfactant necessary for the extraction of Disulfoton was evaluated and that which provided the greatest recovery percentage above 90 % was 1.0 % (w/v) of Triton X-114. It was verified, also, the influence of some factors in the efficiency of the extraction of Disulfoton from water, such as variation of the pH of the sample, the increase of the ionic strength and the presence of other surfactants. The ionic strength was the factor of largest influence, increasing the percentage of recovery of Disulfoton to nearly 100 %, while the presence of other surfactants, such as Triton X-100 or SDS, reduced the efficiency of extraction of the method. The cloud point extraction of Disulfoton from water, coupled to a system of "cleanup", composed of silica-gel and Florisil columns, was shown, for the evaluated parameters of validation, to be at least comparable to the conventional method, besides being a simple method with easy execution. Due to significant reduction of the volume of solvent employed, it also was, economical and ecologically viable.
7

Desenvolvimento de Procedimento Analítico para Extração e Pré-Concentração de Ferro em Amostras de Água de Produção Usando Extração em Ponto Nuvem e Espectrometria de Absorção Atômica com Chama / Analytical Procedure Development paragraph Extraction and Pre - Iron Concentration in Production Water Samples Using Cloud Point Extraction and Atomic Absorption Spectrometry Flame

Gondim, Tamyris de Aquino January 2015 (has links)
GONDIM, Tamyris de Aquino. Desenvolvimento de Procedimento Analítico para Extração e Pré-Concentração de Ferro em Amostras de Água de Produção Usando Extração em Ponto Nuvem e Espectrometria de Absorção Atômica com Chama. 2015. 90 f. Dissertação (mestrado em química)- Universidade Federal do Ceará, Fortaleza-CE, 2015. / Submitted by Elineudson Ribeiro (elineudsonr@gmail.com) on 2016-04-05T17:08:18Z No. of bitstreams: 1 2016_dis_tagondim.pdf: 2153557 bytes, checksum: 3791b8d59c11fb4e6c75bcb2d87f2de7 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa (jairo@ufc.br) on 2016-05-20T17:47:10Z (GMT) No. of bitstreams: 1 2016_dis_tagondim.pdf: 2153557 bytes, checksum: 3791b8d59c11fb4e6c75bcb2d87f2de7 (MD5) / Made available in DSpace on 2016-05-20T17:47:10Z (GMT). No. of bitstreams: 1 2016_dis_tagondim.pdf: 2153557 bytes, checksum: 3791b8d59c11fb4e6c75bcb2d87f2de7 (MD5) Previous issue date: 2015 / Produced water from petroleum industry is characterized by their high salinity and its complex composition. Depending on its origin, the produced water may contain a variety of chemicals such as organic salts, aliphatic hydrocarbons, polycyclic aromatic hydrocarbons (HPA), potentially toxic metals and radioactive materials. Therefore, the disposal of these production waters can be considered a major problem for the oil industry, since the produced water must be characterized and treated before being discarded at sea. This characterization includes evaluating the concentration of inorganic elements; however, the determination of these elements is not a simple procedure because of the complexity of the sample matrix, which has high salinity causing scattering and suppression of analytical signal in spectrometric analysis. This work proposes a methodology to iron quantification in saline produced water from oil industry by flame atomic absorption spectrometry (FAAS) after cloud point extraction (EPN). The procedure is based on the cloud point extraction using PAN as complexing agent and Triton X-114 as surfactant. The parameters that can influence the CPE were studied and optimized using a Box-Behnken design in order to get the best conditions for iron extraction. The CPE has the advantage of being a simple, low cost, in accordance with the green chemistry, selective and preconcentration factor compatible with other traditional methods. The proposed method was validated by obtaining a limit of quantification of 0.010 mg L-1 and detection limit of 0.003 mg L-1. Linear response within 0,02 and 0,40 mg L-1 . The precision of the method was evaluated in terms of repeatability, obtaining a coefficient of variation of CVm 0.67 %. The accuracy of the method was assessed by recovery experiments of Fe fortification in three concentration levels that presented recovery of Rm 101.58 %. The method applied with satisfactory performance to determine iron production waters. / Águas de produção são caracterizadas pela alta salinidade e sua composição complexa. Dependendo da sua origem, as águas de produção podem conter uma variedade de substâncias químicas, tais como sais orgânicos, hidrocarbonetos alifáticos, hidrocarbonetos aromáticos policíclicos (HAP), metais potencialmente tóxicos e materiais radioativos. Portanto, o descarte dessas águas de produção pode ser considerado um grande problema para a indústria petrolífera, visto que as águas de produção têm de ser caracterizadas e tratadas antes de serem rejeitadas no mar. Essa caracterização inclui a avaliação da concentração de elementos inorgânicos, entretanto, a determinação desses elementos não é um procedimento simples devido à complexidade da matriz da amostra, a qual possui alta salinidade provocando espalhamento e supressão de sinal analítico em análises espectrométricas. No presente trabalho é proposto um procedimento para a determinação ferro em água de produção derivada da indústria do petróleo por espectrometria de absorção atômica com chama (FAAS). O procedimento baseia-se na extração em ponto nuvem (EPN) utilizando PAN como agente complexante e Triton X-114 como surfactante. Os parâmetros que podem influenciar na EPN foram estudados e otimizados utilizando-se um planejamento Box-Behnken a fim de obter as melhores condições para extração de Ferro. A EPN tem como vantagens ser um método simples, de baixo custo, em acordo com a química verde, seletivo e com fator de pré-concentração compatível com outros métodos tradicionais. O método proposto foi validado obtendo um limite de quantificação de 0,010 mg L-1, limite de detecção 0,003 mg L-1. Resposta linear foi observada no intervalo de 0,02 a 0,40 mg L-1. A precisão do método foi verificada em termos de repetitividade, obtendo um coeficiente médio de variação (CVm 0,67 %). A exatidão do método foi averiguada por meio de ensaios de recuperação, onde foi realizada a fortificação em três níveis de concentração apresentando Rm 101,58 %. O método foi aplicado com bons resultados para determinação de ferro em águas de produção.
8

Analytical Procedure Development paragraph Extraction and Pre - Iron Concentration in Production Water Samples Using Cloud Point Extraction and Atomic Absorption Spectrometry Flame / Desenvolvimento de Procedimento AnalÃtico para ExtraÃÃo e PrÃ-ConcentraÃÃo de Ferro em Amostras de Ãgua de ProduÃÃo Usando ExtraÃÃo em Ponto Nuvem e Espectrometria de AbsorÃÃo AtÃmica com Chama

Tamyris de Aquino Gondim 20 January 2015 (has links)
CoordenaÃÃo de AperfeÃoamento de Pessoal de NÃvel Superior / Produced water from petroleum industry is characterized by their high salinity and its complex composition. Depending on its origin, the produced water may contain a variety of chemicals such as organic salts, aliphatic hydrocarbons, polycyclic aromatic hydrocarbons (HPA), potentially toxic metals and radioactive materials. Therefore, the disposal of these production waters can be considered a major problem for the oil industry, since the produced water must be characterized and treated before being discarded at sea. This characterization includes evaluating the concentration of inorganic elements; however, the determination of these elements is not a simple procedure because of the complexity of the sample matrix, which has high salinity causing scattering and suppression of analytical signal in spectrometric analysis. This work proposes a methodology to iron quantification in saline produced water from oil industry by flame atomic absorption spectrometry (FAAS) after cloud point extraction (EPN). The procedure is based on the cloud point extraction using PAN as complexing agent and Triton X-114 as surfactant. The parameters that can influence the CPE were studied and optimized using a Box-Behnken design in order to get the best conditions for iron extraction. The CPE has the advantage of being a simple, low cost, in accordance with the green chemistry, selective and preconcentration factor compatible with other traditional methods. The proposed method was validated by obtaining a limit of quantification of 0.010 mg L-1 and detection limit of 0.003 mg L-1. Linear response within 0,02 and 0,40 mg L-1 . The precision of the method was evaluated in terms of repeatability, obtaining a coefficient of variation of CVm 0.67 %. The accuracy of the method was assessed by recovery experiments of Fe fortification in three concentration levels that presented recovery of Rm 101.58 %. The method applied with satisfactory performance to determine iron production waters. / Ãguas de produÃÃo sÃo caracterizadas pela alta salinidade e sua composiÃÃo complexa. Dependendo da sua origem, as Ãguas de produÃÃo podem conter uma variedade de substÃncias quÃmicas, tais como sais orgÃnicos, hidrocarbonetos alifÃticos, hidrocarbonetos aromÃticos policÃclicos (HAP), metais potencialmente tÃxicos e materiais radioativos. Portanto, o descarte dessas Ãguas de produÃÃo pode ser considerado um grande problema para a indÃstria petrolÃfera, visto que as Ãguas de produÃÃo tÃm de ser caracterizadas e tratadas antes de serem rejeitadas no mar. Essa caracterizaÃÃo inclui a avaliaÃÃo da concentraÃÃo de elementos inorgÃnicos, entretanto, a determinaÃÃo desses elementos nÃo à um procedimento simples devido à complexidade da matriz da amostra, a qual possui alta salinidade provocando espalhamento e supressÃo de sinal analÃtico em anÃlises espectromÃtricas. No presente trabalho à proposto um procedimento para a determinaÃÃo ferro em Ãgua de produÃÃo derivada da indÃstria do petrÃleo por espectrometria de absorÃÃo atÃmica com chama (FAAS). O procedimento baseia-se na extraÃÃo em ponto nuvem (EPN) utilizando PAN como agente complexante e Triton X-114 como surfactante. Os parÃmetros que podem influenciar na EPN foram estudados e otimizados utilizando-se um planejamento Box-Behnken a fim de obter as melhores condiÃÃes para extraÃÃo de Ferro. A EPN tem como vantagens ser um mÃtodo simples, de baixo custo, em acordo com a quÃmica verde, seletivo e com fator de prÃ-concentraÃÃo compatÃvel com outros mÃtodos tradicionais. O mÃtodo proposto foi validado obtendo um limite de quantificaÃÃo de 0,010 mg L-1, limite de detecÃÃo 0,003 mg L-1. Resposta linear foi observada no intervalo de 0,02 a 0,40 mg L-1. A precisÃo do mÃtodo foi verificada em termos de repetitividade, obtendo um coeficiente mÃdio de variaÃÃo (CVm 0,67 %). A exatidÃo do mÃtodo foi averiguada por meio de ensaios de recuperaÃÃo, onde foi realizada a fortificaÃÃo em trÃs nÃveis de concentraÃÃo apresentando Rm 101,58 %. O mÃtodo foi aplicado com bons resultados para determinaÃÃo de ferro em Ãguas de produÃÃo
9

Avaliação e caracterização de sistemas baseados em ponto nuvem visando a remoção de albumina do plasma sanguineo / Evaluation and characterization of cloud point based systems for albumin removal from blood plasma

Silva, Marcelo Anselmo Oseas da, 1982- 25 February 2008 (has links)
Orientador: Marco Aurelio Zezzi Arruda / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-10T13:14:37Z (GMT). No. of bitstreams: 1 Silva_MarceloAnselmoOseasda_M.pdf: 1369513 bytes, checksum: 35e33836144e52420b1164f512aa97e9 (MD5) Previous issue date: 2008 / Resumo: Nesta dissertação foi estudado o comportamento de partição da albumina, proteína presente em elevada concentração no plasma sangüíneo e que interfere na determinação em diversas técnicas analíticas. No estudo efetuado foram avaliados diferentes sistemas aquosos de duas fases, explorando um fenômeno denominado ponto nuvem. Tais sistemas empregam surfactantes, sob condições experimentais específicas, obtendo-se a formação de duas fases imiscíveis: uma rica e outra pobre em tensoativo. Observou-se que devido às características hidrofílicas da albumina, bem como à dimensão dos agregados formados, sua extração para fase rica em tensoativo apresenta valores de coeficiente de partição que não ultrapassam 0,66 o que representa uma eficiência de extração de ca.40%. A extração da proteína apresentou-se viável mediante a utilização de uma mistura composta por um tensoativo não-iônico (Triton® X-114), que possibilita a separação de fases em temperatura biocompatível, na presença de outro tensoativo iônico (dodecil sulfato de sódio - SDS), que atua favorecendo as interações eletrostáticas entre os agregados e as moléculas protéicas, desde que se trabalhe em meio com pH abaixo de 5,0. Análises de dicroísmo circular complementaram o estudo e fornecerem evidências de que a aplicação do sistema baseado na mistura composta por Triton® X-114 e SDS causava desnaturação parcial da proteína, o que não inviabilizou sua aplicação para extração da mesma em uma amostra real. A eficiência deste sistema foi, então, avaliada para a remoção de albumina em plasma sangüíneo. Um coeficiente de partição de 1,1 foi obtido, indicando que ca.51% das proteínas encontravam-se na fase rica em tensoativo. As amostras submetidas ao procedimento de extração também foram avaliadas frente à técnica de eletroforese em gel, sendo que a fase pobre em sufactante apresentou um perfil eletroforético mais detalhado quando comparada a uma amostra que não foi submetida ao procedimento proposto. Já na fase rica em surfactante, foi observada a presença majoritária de albumina e, em menor concentração, outras proteínas de grande abundância no plasma tais como imunoglobulina G e transferrina. Por fim, o método apresentou desempenho semelhante ao de sistemas disponíveis comercialmente para remoção de albumina, tal como o sistema da Millipore®, apresentado neste trabalho / Abstract: In this work the partition behavior of albumin was studied, which is found at high concentrations in blood plasma, which interferes in many analytical techniques determinations. The present study evaluated different aqueous two-phase systems, exploiting a phenomenon called of cloud point. These systems employ surfactants under specific experimental conditions, enabling formation of two immiscible phases: one rich and another poor in surfactant. Due to the hydrophilic characteristcs of albumin, as well as its aggregate dimensions, its extration to the surfactant rich phase presented partition coefficients lower than 0.66, representing and extraction efficiency of ca. 40%. Protein extraction was feasible by applying a mixture comprised of a nonionic surfactant (Triton® X-114), which allowed the phase separation at biocompatible temperatures, and an ionic one (sodium dodecylsufate - SDS), wich promotes eletrostatic interactions between aggregates and protein molecules, since the extraction procedure is carried out at pH 5.0. Circular dichroism analysis complemented the study and it showed that a system based on a Triton® X-114 and SDS mixture causes partial protein denaturation, but its application for a real sample is feasible. The efficiency of this was evaluated for albumin removal from blood plasma. A partition coefficient of 1.1 was obtained, indicating that ca. 51% of proteins were contained in the surfactant rich phase. Albumin depleted samples were submitted to gel eletrophoresis and the surfactant poor phase presented a more detailed gel electrophoresis profile, when compared with a crude sample. The surfactant rich phase reveled that albumin is the predominant protein present, but it is possible to find other highly concentrated plasmatic proteins including immunoglobulin G and transferrin. Finally, the method presented similar performance when compared with commercially available systems for albumin removal, such as the Millipore® system, wich was also evaluated in this work / Mestrado / Quimica Analitica / Mestre em Química
10

Desenvolvimento de procedimentos limpos para extração de íons metálicos em ponto nuvem / Development of green analytical procedures for cloud-point extraction of metal ions

Sidnei Gonçalves da Silva 28 February 2008 (has links)
O presente trabalho enfoca o desenvolvimento de procedimentos analíticos limpos através da extração e pré-concentração de íons metálicos em ponto nuvem para aumento de sensibilidade, melhoria de seletividade e substituição de solventes tóxicos. Cobre(II), ferro(II) e níquel(II) foram extraídos simultaneamente em digeridos de materiais vegetais, utilizando como agente extrator o Triton X-114, após formarem complexos hidrofóbicos com o 1,2-tiazolilazo-2-naftol (TAN). Os analitos foram determinados por espectrometria de absorção atômica com chama (Cu, Fe e Ni) ou por espectrofotometria de absorção molecular (Fe). A determinação de Cu e Ni por espectrofotometria de absorção molecular foi inviabilizada por interferências espectrais causadas pela formação de complexos com diversos íons metálicos encontrados nos digeridos dos materiais vegetais. Nas medidas por FAAS, os limites de detecção (99,7 % de confiança) foram estimados em 1,10 e 5 µg L-1 para cobre, ferro e níquel, respectivamente. Respostas lineares foram observadas para cobre e ferro na faixa de concentração de 25-200 µg L-1 e para o níquel entre 5 e 80 µg L-1 . O fator de enriquecimento foi estimado em 30 e a extração dos analitos foi quantitativa, de acordo com medidas efetuadas no sobrenadante após extração. Na determinação de ferro por espectrofotometria de absorção molecular, o limite de detecção foi estimado em 1 µg L-1 , com resposta linear entre 6 e 60 µg L-1 e fator de enriquecimento estimado em 20. Após digestão com ácidos diluídos em forno de microondas, o procedimento proposto foi aplicado à determinação dos analitos em digeridos de materiais de referência certificados, sendo os resultados concordantes com os valores certificados a nível de confiança de 95 %. O consumo de reagentes foi estimado em 50 mg Triton X-114 e 150 µg TAN por determinação. / This work is focused on the development of green analytical procedures for cloud-point extraction and concentration of metal ions, aiming increasing sensitivity, improving selectivity and avoiding the use of toxic solvents. Copper(II), iron(II) and nickel(II) were simultaneously extracted from plant materials digests, by using Triton X-114 as extracting agent, after formation of hydrophobic complexes with 1,2- tiazolylazo-2-naphthol (TAN). The analytes were determined by flame atomic absorption spectrometry (Cu, Fe and Ni) or by molecular absorption spectrophotometry (Fe). The determination of Cu and Ni by UV-vis spectrophotometry was hindered by spectral interferences caused by the formation of complexes with several metal ions in the sample digests. In the measurements by FAAS, the detection limits (99.7 % confidence level) were estimated as 1, 10 and 5 µg L-1 for copper, iron and nickel, respectively. Linear responses were observed in the 25-200 µg L-1 range for copper and iron and 5-80 µg L-1 for nickel. The enrichment factor was estimated as 30 and the extraction was quantitative, as evaluated by measurements in the supernatant solution after extraction. For iron determination by UV-vis spectrophotometry, the detection limit was estimated as 1 µg L-1 , with linear response within 6 and 60 µg L-1 and enrichment factor of 20. After digestion with diluted acids in microwave oven, the procedure was applied to the determination of the metals in reference materials and the results agreed with the certified values at the 95 % confidence level. The reagent consumption was estimated as 50 mg Triton X-114 and 150 µg TAN per determination.

Page generated in 0.0454 seconds