Return to search

Influence of anatomical location and FOV size on cone-beam computed tomography gray values = Análise da influência da localização anatômica e tamanho do FOV nos valores de cinza em imagens de tomografia computadorizada de feixe cônico / Análise da influência da localização anatômica e tamanho do FOV nos valores de cinza em imagens de tomografia computadorizada de feixe cônico

Orientador: Guilherme Monteiro Tosoni / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T22:12:50Z (GMT). No. of bitstreams: 1
Oliveira_MatheusLimade_D.pdf: 24389100 bytes, checksum: b2e18d1167061c00f8285f26e1f8d746 (MD5)
Previous issue date: 2013 / Resumo: O objetivo deste estudo foi avaliar a influência da região anatômica e do tamanho do FOV (field of view) nos valores de cinza em imagens de tomografia computadorizada de feixe cônico (TCFC). Soluções homogêneas de fosfato de potássio dibásico (K2HPO4) foram preparadas em sete diferentes concentrações e armazenadas separadamente em tubos de polipropileno. Um phantom de uma cabeça humana teve seis dentes extraídos - um incisivo central um primeiro prémolar e um primeiro molar da maxila e da mandíbula - e substituídos por esses tubos, que foram escaneados separadamente pelos aparelhos NewTom 3G, NewTom 5G e 3D Accuitomo 170, sob diferentes tamanhos de FOV. Em cortes axiais, valores médios de cinza foram obtidos em cinco níveis diferentes dentro de cada tubo de polipropileno e a média foi calculada. Para cada aparelho, análise de regressão linear avaliou a relação entre os valores médios de cinza e a concentração de K2HPO4 em seis regiões anatômicas, sob os diferentes FOVs. Coeficiente de determinação (R2) foi calculado. Nos três aparelhos, a correlação linear entre os valores de cinza e as concentrações de K2HPO4 variou entre as regiões anatômicas e os tamanhos de FOV (0,93 < R2 < 0,99). Desse modo, pode se concluir que a relação entre os valores de cinza em imagens de TCFC e a densidade do objeto não é uniforme por todo o arco dentário e é influenciada pelo tamanho do FOV nos três aparelhos de TCFC testados. A comparação desses valores obtidos em diferentes regiões anatômicas e com diferentes tamanhos de FOV não é confiável / Abstract: The aim of this study was to evaluate the influence of anatomical location and FOV (field of view) size in CBCT numbers. Homogeneous solutions of dipotassium phosphate (K2HPO4) were prepared at seven different concentrations and stored separately in polypropylene tubes. Six teeth were extracted from a human head phantom - the upper and lower central incisors, first premolars and first molars - and replaced by the tubes, which were scanned separately by NewTom 3G, NewTom 5G and 3D Accuitomo 170 under different FOV sizes. In axial sections, CBCT numbers were obtained at five levels within each polypropylene tube, and the average was calculated. For each CBCT unit, linear regression analysis evaluated the relationship between CBCT numbers and the concentration of K2HPO4 in six anatomical regions, under different FOVs. Coefficient of determination (R2) was calculated. Linear correlation between CBCT numbers and concentrations of K2HPO4 ranged between anatomical regions and FOV sizes (0.93 < R2 <0.99). Thus, it can be concluded that the relationship between CBCT numbers and object density is not uniform throughout the dental arch, and is influenced by the FOV size on the three CBCT units tested in this study. The comparison of CBCT numbers from different anatomical regions and with different FOV sizes is unreliable / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289200
Date02 May 2013
CreatorsOliveira, Matheus Lima de, 1984-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Tosoni, Guilherme Monteiro, Júnior, Luiz Roberto Coutinho Manhães, Gonçalves, Andrea, França, Deborah Queiroz de Freitas, Almeida, Solange Maria de
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Radiologia Odontológica
Source SetsIBICT Brazilian ETDs
LanguageMultilíngua
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format45 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.016 seconds