• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Developing a method for estimating Body Segment Parameters using Dual Photon Absorptiometry, Magnetic Resonance Imaging, and Photogrammetry

Mercuri, Mat 03 1900 (has links)
<p> An accurate estimation of Body Segment Parameters (BSPs) is needed to understand human movement. These include segment mass, centre of mass, and moment of inertia about the centre of mass. Bone density scanners, such as DPX, can measure BSPs, but are limited to only two dimensions. MRI produces images in three dimensions, but cannot directly measure mass. For this study, MRI was used in conjunction with a DPX scan of the human body. The result was the development of a method to estimate mass, and subsequently, centre of mass, and moment of inertia from MRI images. Next, ellipses were created from the dimensions of transverse plane slices (produced from MRI). Three different density profiles were applied to the ellipses, and mass, centre of mass and moment of inertia about the centre of mass of each slice was calculated. It was found that constant density transverse plane ellipses could be used to estimate BSPs for most regions of the body. Photogrammetry can also be used to generate the dimensions of ellipses that represent transverse plane slices. Therefore, the suitability of photogrammetry to estimate slice BSPs was tested. It was found that depending on the density profile used, photogrammetry is an effective method for estimating BSPs. An exception to this estimation was in the chest, where ellipses may not be representative of the body. </p> / Thesis / Master of Science (MSc)
2

Avaliação da composição corporal em pacientes com a forma clássica da hiperplasia adrenal congênital por deficiência da enzima 21-hidroxilase / Assessment of body composition in patients with classic congenital adrenal hyperplasia due to 21-hydroxylase deficiency

Gonçalves, Ezequiel Moreira, 1977- 19 August 2018 (has links)
Orientador: Gil Guerra Júnior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-19T19:08:43Z (GMT). No. of bitstreams: 1 Goncalves_EzequielMoreira_D.pdf: 5365817 bytes, checksum: 7f7c98bf013498181e9a1d0f32614cfc (MD5) Previous issue date: 2012 / Resumo: Objetivos: a) Validar equações com base nas espessuras de dobras cutâneas (EDC) para estimar o percentual de massa gorda (%MG) e na impedância bioelétrica (BIA) para a massa isenta de gordura (MIG) em pacientes com hiperplasia adrenal congênita por deficiência da enzima 21-hidroxilase (HAC-D21OH); b) desenvolver equações específicas para estes pacientes para estimar o %MG e MIG, utilizando os valores determinados pela absorciometria por dupla emissão de raio X (DXA) como referência; e c) avaliar a relação entre os parâmetros da massa óssea (MO) determinados pela ultrassonometria quantitativa (QUS) das falanges proximais e sua capacidade de diagnosticar a baixa MO para a idade cronológica em comparação ao DXA em pacientes com HAC-D21OH. Casuística: Foram avaliados 71 pacientes de ambos os sexos, com idades entre seis e 27 anos. Métodos: Foram realizadas medidas antropométricas, de BIA, de DXA e de QUS em um mesmo dia. Foram testadas quatro equações (Eq. 1, 2, 3 e 4), previamente publicadas para a estimativa do %MG e quatro equações (Eq. 5, 6, 7, e 8) para a estimativa da MIG em kg, todas específicas para o sexo e faixa etária. Foram utilizados o teste t de Student, os parâmetros da regressão linear simples e a concordância entre os métodos para testar a validade das equações, regressão linear múltipla para desenvolver os novos modelos e a análise dos parâmetros da curva ROC para avaliar a capacidade diagnóstica do QUS. Resultados: Eq. 1, 2, 3, e 4, apresentaram alta correlação (R>0,80), porém subestimaram significativamente (p<0,01) os valores de %MG em comparação ao DXA. Com relação à MIG, apesar de todas as equações apresentarem R> 0,95, no geral apenas uma apresentou validade considerada aceitável (Eq. 6, grupo masculino). Foram desenvolvidas e validadas quatro equações propostas no presente estudo específicas para a estimativa do %MG e uma para a estimativa da MIG em pacientes HAC-D21OH. Os parâmetros do QUS apresentaram valores variando entre: 0,57-0,74 (R), 62,5-100% (sensibilidade) e 21-64,4% (especificidade) em relação ao DXA. Conclusão: As equações específicas para indivíduos com HAC-D21OH demonstraram maior validade para estimar a MIG e principalmente o %MG, comparadas as equações previamente publicadas e desenvolvidas a partir de amostras com pessoas saudáveis. O QUS apresentou relação significativa, porém moderada e baixa capacidade de diagnosticar a baixa MO para a idade cronológica quando comparado ao DXA nestes pacientes / Abstract: Objectives: a) To evaluate the accuracy of skinfold-based models, to estimate the percentage of fat mass (%FM) and the bioelectrical impedance analysis (BIA) to estimate fat-free mass (FFM) in patients with congenital adrenal hyperplasia due to 21-hydroxylase deficiency (CAH-21OHD); b) to develop specific equations for these patients to estimate the % MG and MIG using dual-energy X-ray absorptiometry (DXA) as the reference method; and c) to evaluate the relationship between the parameters of bone mass (BM) determined by quantitative ultrasound of proximal phalanges (QUS) and the ability to diagnose low bone mass for chronological age in comparison to DXA in patients with CAH-21OHD. Patients: Seventy one patients of both genders, with age ranged from six and 27 years were inclued. Methods: Anthropometric measurements, BIA, DXA and to QUS were evaluated in the same day. Four equations (Eq. 1, 2, 3 and 4) previously published to estimate the %FM, and four equations (Eq. 5, 6, 7, and 8) to estimated the FFM, all specific for sex and age, the Student t test, the parameters of simple linear regression and the agreement between methods were used to test the validity of the equations, multiple linear regression to develop the new model and the parameters of the ROC curve to evaluate the diagnostic ability of QUS. Results: The four equations (Eq. 1, 2, 3, and 4) were highly correlated (R>0.80), but the %FM values were significantly underestimated (p<0.01) when compared to DXA. With respect to MIG, despite all the equations presented R>0.95, only one had acceptable validity (Eq. 6 for males). Four new specific equations to estimated %FM and one FFM were developed and validate in patients with CAH-21OHD. QUS parameters showed values ranging from 0.57 to 0.74 (R), 62.5 to 100% (sensitivity) and 21 to 64.4% (specificity) compared to DXA. Conclusion: The new specific equations for patients with CAH-21OHD showed greater validity to estimate FFM and mainly the %FM compared to previously equations published and developed with samples from healthy pearsons. The QUS showed a significant relationship, but moderate and low ability to diagnose low bone mass for chronological age when compared to DXA in these patients / Doutorado / Saude da Criança e do Adolescente / Doutor em Saude da Criança e do Adolescente
3

Influence of anatomical location and FOV size on cone-beam computed tomography gray values = Análise da influência da localização anatômica e tamanho do FOV nos valores de cinza em imagens de tomografia computadorizada de feixe cônico / Análise da influência da localização anatômica e tamanho do FOV nos valores de cinza em imagens de tomografia computadorizada de feixe cônico

Oliveira, Matheus Lima de, 1984- 02 May 2013 (has links)
Orientador: Guilherme Monteiro Tosoni / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T22:12:50Z (GMT). No. of bitstreams: 1 Oliveira_MatheusLimade_D.pdf: 24389100 bytes, checksum: b2e18d1167061c00f8285f26e1f8d746 (MD5) Previous issue date: 2013 / Resumo: O objetivo deste estudo foi avaliar a influência da região anatômica e do tamanho do FOV (field of view) nos valores de cinza em imagens de tomografia computadorizada de feixe cônico (TCFC). Soluções homogêneas de fosfato de potássio dibásico (K2HPO4) foram preparadas em sete diferentes concentrações e armazenadas separadamente em tubos de polipropileno. Um phantom de uma cabeça humana teve seis dentes extraídos - um incisivo central um primeiro prémolar e um primeiro molar da maxila e da mandíbula - e substituídos por esses tubos, que foram escaneados separadamente pelos aparelhos NewTom 3G, NewTom 5G e 3D Accuitomo 170, sob diferentes tamanhos de FOV. Em cortes axiais, valores médios de cinza foram obtidos em cinco níveis diferentes dentro de cada tubo de polipropileno e a média foi calculada. Para cada aparelho, análise de regressão linear avaliou a relação entre os valores médios de cinza e a concentração de K2HPO4 em seis regiões anatômicas, sob os diferentes FOVs. Coeficiente de determinação (R2) foi calculado. Nos três aparelhos, a correlação linear entre os valores de cinza e as concentrações de K2HPO4 variou entre as regiões anatômicas e os tamanhos de FOV (0,93 < R2 < 0,99). Desse modo, pode se concluir que a relação entre os valores de cinza em imagens de TCFC e a densidade do objeto não é uniforme por todo o arco dentário e é influenciada pelo tamanho do FOV nos três aparelhos de TCFC testados. A comparação desses valores obtidos em diferentes regiões anatômicas e com diferentes tamanhos de FOV não é confiável / Abstract: The aim of this study was to evaluate the influence of anatomical location and FOV (field of view) size in CBCT numbers. Homogeneous solutions of dipotassium phosphate (K2HPO4) were prepared at seven different concentrations and stored separately in polypropylene tubes. Six teeth were extracted from a human head phantom - the upper and lower central incisors, first premolars and first molars - and replaced by the tubes, which were scanned separately by NewTom 3G, NewTom 5G and 3D Accuitomo 170 under different FOV sizes. In axial sections, CBCT numbers were obtained at five levels within each polypropylene tube, and the average was calculated. For each CBCT unit, linear regression analysis evaluated the relationship between CBCT numbers and the concentration of K2HPO4 in six anatomical regions, under different FOVs. Coefficient of determination (R2) was calculated. Linear correlation between CBCT numbers and concentrations of K2HPO4 ranged between anatomical regions and FOV sizes (0.93 < R2 <0.99). Thus, it can be concluded that the relationship between CBCT numbers and object density is not uniform throughout the dental arch, and is influenced by the FOV size on the three CBCT units tested in this study. The comparison of CBCT numbers from different anatomical regions and with different FOV sizes is unreliable / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica

Page generated in 0.0892 seconds