Return to search

Reforço parcial de abertura transversal em vigas de concreto armado por meio de adição de fibras metálicas à massa do concreto.

Submitted by Haroudo Xavier Filho (haroudo.xavierfo@ufpe.br) on 2016-04-15T18:13:42Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertação - Paulo Rodrigo Lopes de Souza.pdf: 3087983 bytes, checksum: 88991d54c050c5fbdd84af04c1508190 (MD5) / Made available in DSpace on 2016-04-15T18:13:42Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertação - Paulo Rodrigo Lopes de Souza.pdf: 3087983 bytes, checksum: 88991d54c050c5fbdd84af04c1508190 (MD5)
Previous issue date: 2015-10-09 / A falta de compatibilização de projetos na construção civil pode gerar interferências entre os diversos projetos de uma edificação e o projeto estrutural, uma destas interferências é a passagem de tubulações na alma de vigas. Na maioria das vezes só é constatado que uma tubulação irá passar no meio de uma viga após a mesma já ter sido concretada e nessa situação muitos construtores realizam uma abertura ou furo na viga para realizar a passagem da tubulação na maior parte das vezes sem a devida consulta a um engenheiro calculista e sem respeitar as prescrições da norma ABNT NBR 6118:2014 no que diz respeito às dimensões e posicionamento na alma da viga ocasionando perda da resistência dessas vigas. Com base no exposto, foi analisada neste trabalho a possibilidade de se adicionar fibras de aço à massa do concreto para atuar como reforço parcial junto ao local do furo. Para avaliar a capacidade das fibras que atua como reforços parciais foram conduzidos ensaios experimentais que consistiram na moldagem de vigas de concreto armado com iguais dimensões onde todas elas foram instrumentadas com extensômetros elétricos e medidores de deslocamento tipo LVDT. As vigas possuíam adição de fibras de aço em diferentes teores e uma abertura transversal de igual geometria e posição na alma. Para realização de um estudo comparativo foram analisadas duas vigas, uma de referência sem adição de fibras à massa do concreto e sem abertura transversal na alma e uma sem adição de fibras de aço à massa do concreto, com abertura transversal na alma, porém, com um reforço em armadura de aço junto ao local da abertura que foi calculado pelo método das Bielas e dos Tirantes. Todas as vigas foram analisadas quando a capacidade de carga, deformações do concreto e do aço além de flecha no meio do vão. Os resultados mostraram que as vigas com adição de fibras de aço à massa do concreto, em alguns locais da viga, alcançaram até a carga de ruptura uma discreta melhora na rigidez, que mostra que as fibras de aço foram eficientes no controle da fissuração, porém as fibras de aço sozinhas não conseguiram manter a mesma capacidade de carga da viga de referência. Sugere-se então a utilização da técnica da adição de fibras de aço à massa do concreto em conjunto com um reforço em armadura de aço junto ao local da abertura calculado pelo método das bielas e dos tirantes. / The lack of compatibility of projects in a civil construction can cause interference among the various projects of a building and the structural project, one of these are interferences in the passage of pipes in the beam’s web. In most cases it is only ascertained that a pipe will go through a beam after it has already been concreted, and in this situation many builders perform an opening or hole in the beam to get the pipes through at most times without proper refers to a calculating engineer and without complying with the requirements of the Brazilian standard NBR 6118: 2014 with regard to the dimensions and positioning the beam’s web causing loss of strength on them. Based on this fact presented above, it was analyzed in this study the possibility of adding steel fibers to the concrete mass to act as partial reinforcement at the place of the hole. To evaluate the ability of the fibers act as partial reinforcement, experimental trials were conducted, which consisted of molding reinforced concrete beams with equal dimensions where all of them were instrumented with electric strain gages and LVDT displacement meters. The beams had addition of steel fibers at different levels and a transverse opening of the same geometry and position in the web. To conduct a comparative study two beams were analyzed, one of them being a reference without addition of fiber to the concrete mass and without transverse opening in the web. The other without the addition of steel fibers to the concrete mass, with cross opening in the web, however, with an increase in steel armor at the place of opening which was calculated by the struts an tie method. All beams were analyzed for the load capacity of concrete and steel strains plus arrow in the middle of the span. The results showed that the beams with added steel fibers to the concrete mass, in some places the beam, reached to a discrete breaking load improvement in rigidity, which shows that steel fibers were effective in controlling cracking, but the steel fibers alone do not show the same load capacity of the reference beam. It is then suggested to use the technique of adding steel fibers to the concrete mass together with a reinforcement of steel armor at the place of the opening calculated by the struts and tie method.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpe.br:123456789/16643
Date09 October 2015
CreatorsSOUZA, Paulo Rodrigo Lopes de.
ContributorsLIMA JÚNIOR, Humberto Correia de
PublisherUniversidade Federal de Pernambuco, Programa de Pos Graduacao em Engenharia Civil e Ambiental, UFPE, Brasil
Source SetsIBICT Brazilian ETDs
LanguageBreton
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFPE, instname:Universidade Federal de Pernambuco, instacron:UFPE
RightsAttribution-NonCommercial-NoDerivs 3.0 Brazil, http://creativecommons.org/licenses/by-nc-nd/3.0/br/, info:eu-repo/semantics/openAccess

Page generated in 0.0028 seconds