Conselho Nacional de Desenvolvimento Científico e Tecnológico / O objetivo deste trabalho foi avaliar o efeito de um diodo emissor de luz (LED) Smart Lite PS (Dentsply) e da lâmpada halógena convencional Curing Light XL 3000 (3M) na efetividade de polimerização do compômero Dyract Ap (Dentsply) e da resina composta TPH Spectrum (Dentsply) por meio de testes de microdureza Knoop, resistência à compressão e resistência flexural e caracterização dos materiais. Foram confeccionadas 100 amostras e divididas em 12 grupos de acordo com o teste aplicado, a luz de polimerização e o material utilizado. A lâmpada halógena convencional selecionada, Curing Light XL 3000 (3M), tinha intensidade de 470mW/cm2 e comprimento de onda entre 400 e 510nm; o LED Smart Lite PS (Dentsply) tinha intensidade de 950mW/cm2 e comprimento de onda entre 450 e 490nm. O tempo de fotopolimerização para cada incremento com 2mm de espessura foi de 40 s. para a lâmpada halógena convencional e 10 s. para o LED. Para os testes de microdureza Knoop foram confeccionadas 20 amostras numa matriz cilíndrica com 8,0mm de diâmetro e 2,0mm de altura. As leituras da microdureza foram realizadas nas superfícies superiores e inferiores das amostras utilizando um microdurômetro Micromet 2003, com uma carga de 50 gf por 15 s. Para o teste de resistência à compressão foram confeccionadas 40 amostras numa matriz cilíndrica com 4,0mm de diâmetro e 8,0mm de altura. A resistência foi medida na máquina de teste universal de ensaios Emic DL 10.000 com uma célula de carga 500Kgf e velocidade de carregamento de 0,5 mm/min. Para o teste de resistência flexural foram construídas 40 amostras numa matriz em forma de caixa com 25,0mm de comprimento, 2,0mm de altura e 2,0mm de largura. A resistência foi medida na máquina de teste universal de ensaios Emic DL 10.000 com uma célula de carga 50Kgf e velocidade de carregamento de 0,5 mm/min. Cada material foi caracterizado pela termogravimetria, espectrometria no infravermelho, espectrometria de ressonância magnética nuclear, teor de cinzas, fluorescência de raios-X e microscopia eletrônica de varredura. Os resultados foram tratados por ANOVA e teste de SNK (p<0,05). Os resultados de microdureza Knoop, resistência à compressão e resistência flexural providos pela luz halógena foram melhores que os dos LED. A resina composta apresentou melhor performance que o compômero em todos os testes. / The goal of this work was to evaluate the effects of the blue light emitting diodes (LEDs) Smart Lite PS (Dentsply) and the conventional halogen lamp Curing Light XL 3000 (3M) on the polymerization effectiveness of the Dyract Ap compomer (Dentsply) and the TPH Spectrum composite resin (Dentsply) by the Knoop microhardness, compressive strength, flexural strength and material characterization tests. A hundred samples were prepared and divided into 12 groups according to the test applied, the polymerization light and the material. The conventional halogen lamp light had power of 470mW/cm and wavelength between 400 and 510nm; the LED light had power of 950mW/cm and wavelength between 450 and 490nm. The polymerization time for each material 2mm buildup was 40 seconds for the conventional halogen lamp and 10 seconds for LED. For the Knoop microhardness tests the 20 samples were cylinder shaped, 8mm diameter and 2mm height. The hardness was read in the upper and lower side of the samples by a micrometer (Micromet 2003), with 50 gf for 15 seconds. For the compressive strength test the 40 samples were cylinder shaped, 4mm diameter and 8mm height. The strength was measured in an universal testing machine Emic DL 10.000 with 500Kgf and cross-head speed of 0,5 mm/min. For the flexural strength test the 40 samples were box shaped, 25mm length, 2mm width and 2mm height. The strength was measured in an universal testing machine Emic DL 10.000 machine with 50Kgf and cross-head speed of 0,5 mm/min. Each material was characterized by Thermogravimetry, FT-IR analysis, Nuclear Magnetic Resonance, Ash Content Test, X-Ray Fluorescence and Scanning Electron Microscopy. The results were treated by ANOVA and SNK tests (p<0,05). The Knoop microhardness, compressive strength and flexural strength results provided by the halogen light lamp were better than the LED ones. The composite resin performed better than the compomer in all mechanical tests.
Identifer | oai:union.ndltd.org:IBICT/urn:repox.ist.utl.pt:BDTD_UERJ:oai:www.bdtd.uerj.br:368 |
Date | 15 September 2006 |
Creators | Cecy Martins Silva |
Contributors | Katia Regina Hostilio Cervantes Dias, Luis Claudio Mendes, Mauro Sayão de Miranda, Élio Vaz da Silva, Márcio Antônio Paraizo Borges, Ivo Carlos Corrêa, Rodrigo Sant'Anna Aguiar dos Reis |
Publisher | Universidade do Estado do Rio de Janeiro, Programa de Pós-Graduação em Odontologia, UERJ, BR |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Format | application/pdf |
Source | reponame:Biblioteca Digital de Teses e Dissertações da UERJ, instname:Universidade do Estado do Rio de Janeiro, instacron:UERJ |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0074 seconds