• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da efetividade da fotoativação de dois materiais resinosos com diferentes fontes de luz, por meio da microdureza Knoop, resistência à compressão, resistência flexural e caracterização dos materiais / Evaluation of the effect of the light source on the photo polymerization of two resin material by the Knoop microhardness, compressive strength, flexural strength and material characterization

Cecy Martins Silva 15 September 2006 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / O objetivo deste trabalho foi avaliar o efeito de um diodo emissor de luz (LED) Smart Lite PS (Dentsply) e da lâmpada halógena convencional Curing Light XL 3000 (3M) na efetividade de polimerização do compômero Dyract Ap (Dentsply) e da resina composta TPH Spectrum (Dentsply) por meio de testes de microdureza Knoop, resistência à compressão e resistência flexural e caracterização dos materiais. Foram confeccionadas 100 amostras e divididas em 12 grupos de acordo com o teste aplicado, a luz de polimerização e o material utilizado. A lâmpada halógena convencional selecionada, Curing Light XL 3000 (3M), tinha intensidade de 470mW/cm2 e comprimento de onda entre 400 e 510nm; o LED Smart Lite PS (Dentsply) tinha intensidade de 950mW/cm2 e comprimento de onda entre 450 e 490nm. O tempo de fotopolimerização para cada incremento com 2mm de espessura foi de 40 s. para a lâmpada halógena convencional e 10 s. para o LED. Para os testes de microdureza Knoop foram confeccionadas 20 amostras numa matriz cilíndrica com 8,0mm de diâmetro e 2,0mm de altura. As leituras da microdureza foram realizadas nas superfícies superiores e inferiores das amostras utilizando um microdurômetro Micromet 2003, com uma carga de 50 gf por 15 s. Para o teste de resistência à compressão foram confeccionadas 40 amostras numa matriz cilíndrica com 4,0mm de diâmetro e 8,0mm de altura. A resistência foi medida na máquina de teste universal de ensaios Emic DL 10.000 com uma célula de carga 500Kgf e velocidade de carregamento de 0,5 mm/min. Para o teste de resistência flexural foram construídas 40 amostras numa matriz em forma de caixa com 25,0mm de comprimento, 2,0mm de altura e 2,0mm de largura. A resistência foi medida na máquina de teste universal de ensaios Emic DL 10.000 com uma célula de carga 50Kgf e velocidade de carregamento de 0,5 mm/min. Cada material foi caracterizado pela termogravimetria, espectrometria no infravermelho, espectrometria de ressonância magnética nuclear, teor de cinzas, fluorescência de raios-X e microscopia eletrônica de varredura. Os resultados foram tratados por ANOVA e teste de SNK (p<0,05). Os resultados de microdureza Knoop, resistência à compressão e resistência flexural providos pela luz halógena foram melhores que os dos LED. A resina composta apresentou melhor performance que o compômero em todos os testes. / The goal of this work was to evaluate the effects of the blue light emitting diodes (LEDs) Smart Lite PS (Dentsply) and the conventional halogen lamp Curing Light XL 3000 (3M) on the polymerization effectiveness of the Dyract Ap compomer (Dentsply) and the TPH Spectrum composite resin (Dentsply) by the Knoop microhardness, compressive strength, flexural strength and material characterization tests. A hundred samples were prepared and divided into 12 groups according to the test applied, the polymerization light and the material. The conventional halogen lamp light had power of 470mW/cm and wavelength between 400 and 510nm; the LED light had power of 950mW/cm and wavelength between 450 and 490nm. The polymerization time for each material 2mm buildup was 40 seconds for the conventional halogen lamp and 10 seconds for LED. For the Knoop microhardness tests the 20 samples were cylinder shaped, 8mm diameter and 2mm height. The hardness was read in the upper and lower side of the samples by a micrometer (Micromet 2003), with 50 gf for 15 seconds. For the compressive strength test the 40 samples were cylinder shaped, 4mm diameter and 8mm height. The strength was measured in an universal testing machine Emic DL 10.000 with 500Kgf and cross-head speed of 0,5 mm/min. For the flexural strength test the 40 samples were box shaped, 25mm length, 2mm width and 2mm height. The strength was measured in an universal testing machine Emic DL 10.000 machine with 50Kgf and cross-head speed of 0,5 mm/min. Each material was characterized by Thermogravimetry, FT-IR analysis, Nuclear Magnetic Resonance, Ash Content Test, X-Ray Fluorescence and Scanning Electron Microscopy. The results were treated by ANOVA and SNK tests (p<0,05). The Knoop microhardness, compressive strength and flexural strength results provided by the halogen light lamp were better than the LED ones. The composite resin performed better than the compomer in all mechanical tests.
2

Avaliação da efetividade da fotoativação de dois materiais resinosos com diferentes fontes de luz, por meio da microdureza Knoop, resistência à compressão, resistência flexural e caracterização dos materiais / Evaluation of the effect of the light source on the photo polymerization of two resin material by the Knoop microhardness, compressive strength, flexural strength and material characterization

Cecy Martins Silva 15 September 2006 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / O objetivo deste trabalho foi avaliar o efeito de um diodo emissor de luz (LED) Smart Lite PS (Dentsply) e da lâmpada halógena convencional Curing Light XL 3000 (3M) na efetividade de polimerização do compômero Dyract Ap (Dentsply) e da resina composta TPH Spectrum (Dentsply) por meio de testes de microdureza Knoop, resistência à compressão e resistência flexural e caracterização dos materiais. Foram confeccionadas 100 amostras e divididas em 12 grupos de acordo com o teste aplicado, a luz de polimerização e o material utilizado. A lâmpada halógena convencional selecionada, Curing Light XL 3000 (3M), tinha intensidade de 470mW/cm2 e comprimento de onda entre 400 e 510nm; o LED Smart Lite PS (Dentsply) tinha intensidade de 950mW/cm2 e comprimento de onda entre 450 e 490nm. O tempo de fotopolimerização para cada incremento com 2mm de espessura foi de 40 s. para a lâmpada halógena convencional e 10 s. para o LED. Para os testes de microdureza Knoop foram confeccionadas 20 amostras numa matriz cilíndrica com 8,0mm de diâmetro e 2,0mm de altura. As leituras da microdureza foram realizadas nas superfícies superiores e inferiores das amostras utilizando um microdurômetro Micromet 2003, com uma carga de 50 gf por 15 s. Para o teste de resistência à compressão foram confeccionadas 40 amostras numa matriz cilíndrica com 4,0mm de diâmetro e 8,0mm de altura. A resistência foi medida na máquina de teste universal de ensaios Emic DL 10.000 com uma célula de carga 500Kgf e velocidade de carregamento de 0,5 mm/min. Para o teste de resistência flexural foram construídas 40 amostras numa matriz em forma de caixa com 25,0mm de comprimento, 2,0mm de altura e 2,0mm de largura. A resistência foi medida na máquina de teste universal de ensaios Emic DL 10.000 com uma célula de carga 50Kgf e velocidade de carregamento de 0,5 mm/min. Cada material foi caracterizado pela termogravimetria, espectrometria no infravermelho, espectrometria de ressonância magnética nuclear, teor de cinzas, fluorescência de raios-X e microscopia eletrônica de varredura. Os resultados foram tratados por ANOVA e teste de SNK (p<0,05). Os resultados de microdureza Knoop, resistência à compressão e resistência flexural providos pela luz halógena foram melhores que os dos LED. A resina composta apresentou melhor performance que o compômero em todos os testes. / The goal of this work was to evaluate the effects of the blue light emitting diodes (LEDs) Smart Lite PS (Dentsply) and the conventional halogen lamp Curing Light XL 3000 (3M) on the polymerization effectiveness of the Dyract Ap compomer (Dentsply) and the TPH Spectrum composite resin (Dentsply) by the Knoop microhardness, compressive strength, flexural strength and material characterization tests. A hundred samples were prepared and divided into 12 groups according to the test applied, the polymerization light and the material. The conventional halogen lamp light had power of 470mW/cm and wavelength between 400 and 510nm; the LED light had power of 950mW/cm and wavelength between 450 and 490nm. The polymerization time for each material 2mm buildup was 40 seconds for the conventional halogen lamp and 10 seconds for LED. For the Knoop microhardness tests the 20 samples were cylinder shaped, 8mm diameter and 2mm height. The hardness was read in the upper and lower side of the samples by a micrometer (Micromet 2003), with 50 gf for 15 seconds. For the compressive strength test the 40 samples were cylinder shaped, 4mm diameter and 8mm height. The strength was measured in an universal testing machine Emic DL 10.000 with 500Kgf and cross-head speed of 0,5 mm/min. For the flexural strength test the 40 samples were box shaped, 25mm length, 2mm width and 2mm height. The strength was measured in an universal testing machine Emic DL 10.000 machine with 50Kgf and cross-head speed of 0,5 mm/min. Each material was characterized by Thermogravimetry, FT-IR analysis, Nuclear Magnetic Resonance, Ash Content Test, X-Ray Fluorescence and Scanning Electron Microscopy. The results were treated by ANOVA and SNK tests (p<0,05). The Knoop microhardness, compressive strength and flexural strength results provided by the halogen light lamp were better than the LED ones. The composite resin performed better than the compomer in all mechanical tests.
3

"Efeitos de bebidas com baixo pH e da escovação dental simulada sobre os materiais restauradores utilizados em lesões cervicais não cariosas" / Effect of acidic beverages and toothbrushing upon restorative materials used in noncarious cervical lesion

Braga, Sheila Regina Maia 07 June 2005 (has links)
O presente estudo analisou in vitro o efeito de bebidas com baixo pH (suco de laranja, Coca-Cola e uísque) e da escovação dental simulada sobre os materiais restauradores utilizados em lesões cervicais não cariosas: resina composta microhíbrida Filtek Z250/3M, resina composta de micropartículas Durafill VS/Heraeus Kulzer, resina composta flow Natural Flow/DFL, compômero Dyract AP/Dentsply, cimento de ionômero de vidro resino-modificado Vitremer/3M. Os materiais foram avaliados quanto à alteração de peso e rugosidade superficial, em balança analítica e em rugosímetro, respectivamente. Foram confeccionados vinte corpos-de-prova de 10 mm de diâmetro e 4 mm de espessura, de cada material. Cinco corpos-de-prova de cada material foram imersos nas bebidas testadas, por 10 dias a 37 °C, com trocas diárias das bebidas. A água destilada foi utilizada como controle. Após a imersão, os corpos-de-prova foram submetidos a 20.000 ciclos de escovação, utilizando escovas de cerdas macias e solução creme dental/água destilada na proporção 1:2. A alteração de peso foi determinada pela porcentagem correspondente à diferença de peso inicial e total (após erosão + escovação). A alteração da rugosidade superficial foi determinada pela diferença entre a rugosidade inicial e total (após erosão + escovação). Os resultados obtidos foram submetidos à análise de ANOVA e Tukey com p<0,05. A imersão em suco de laranja e Coca-Cola, seguida pela escovação, causou maior alteração de peso, estatisticamente significante para o Dyract (-2,55%/-1,72%) e para o Vitremer (-5,03%/-2,42%) comparados às RC Z250 (0,33%/0,20%), Durafill (0,17%/-0,18%) e Natural Flow (-0,14%/-0,17%).O CIVRM Vitremer apresentou as maiores alterações de rugosidade superficial (2,96 mm/1,59 mm) após imersão em suco de laranja e Coca-Cola, seguida de escovação. Houve correlação entre alteração de peso e rugosidade superficial / This study evaluated in vitro the effect of acidic beverages (orange juice, Coca-Cola soft drink, whisky) and toothbrushing upon restorative materials used in noncarious cervical lesions: one hybrid composite (Filtek Z250/3M), one microfill composite (Durafill VS/Heraeus Kulzer), one flow composite (Natural Flow/DFL), one compomer (Dyract/Dentsply) and one resin-modified glass ionomer (Vitremer/3M). Twenty standardized cylindrical specimens (10 mm in diameter and 4 mm thickness) of each material was made. In this research, measures of the changes in weight and roughness surface were carried out using a analytical scale and a rugosimeter, respectively. Five specimens of each material were immersed in test solutions for a 10-day period at a temperature of 37 °C. Distilled water was used like a control. After erosion, the specimens were submitted to 20,000 strokes of toothbrus hing using soft bristles tips and a slurry contained a 1:2 mixture of toothpaste and distilled water. The changes of weight was calculated by percentage corresponded of difference between initial and total weights (before and after erosion + toothbrusing). The changes of roughness was determined by difference between initial and total roughness (before and after erosion + toothbrushing). The data were analyzed using analysis of variance (ANOVA) and Tukey Test at level of p<0.05. The immersion in orange juice and Coca-Cola followed by toothbrushing caused higher changes of weight, statistically significant, for Dyract (-2.55%/-1.72%) and Vitremer (-5.03%/-2.42%) compared to Z250 (0.33%/0.20%), Durafill (0.17%/-0.18%) and Natural Flow (-0.14%/-0.17%). Vitremer presented the highest changes of surface roughness (2.96 mm/1.59 mm) after immersion in orange juice and Coca-Cola followed by toothbrushing. There was correlation between changes of weight and roughness.
4

"Efeitos de bebidas com baixo pH e da escovação dental simulada sobre os materiais restauradores utilizados em lesões cervicais não cariosas" / Effect of acidic beverages and toothbrushing upon restorative materials used in noncarious cervical lesion

Sheila Regina Maia Braga 07 June 2005 (has links)
O presente estudo analisou in vitro o efeito de bebidas com baixo pH (suco de laranja, Coca-Cola e uísque) e da escovação dental simulada sobre os materiais restauradores utilizados em lesões cervicais não cariosas: resina composta microhíbrida Filtek Z250/3M, resina composta de micropartículas Durafill VS/Heraeus Kulzer, resina composta flow Natural Flow/DFL, compômero Dyract AP/Dentsply, cimento de ionômero de vidro resino-modificado Vitremer/3M. Os materiais foram avaliados quanto à alteração de peso e rugosidade superficial, em balança analítica e em rugosímetro, respectivamente. Foram confeccionados vinte corpos-de-prova de 10 mm de diâmetro e 4 mm de espessura, de cada material. Cinco corpos-de-prova de cada material foram imersos nas bebidas testadas, por 10 dias a 37 °C, com trocas diárias das bebidas. A água destilada foi utilizada como controle. Após a imersão, os corpos-de-prova foram submetidos a 20.000 ciclos de escovação, utilizando escovas de cerdas macias e solução creme dental/água destilada na proporção 1:2. A alteração de peso foi determinada pela porcentagem correspondente à diferença de peso inicial e total (após erosão + escovação). A alteração da rugosidade superficial foi determinada pela diferença entre a rugosidade inicial e total (após erosão + escovação). Os resultados obtidos foram submetidos à análise de ANOVA e Tukey com p<0,05. A imersão em suco de laranja e Coca-Cola, seguida pela escovação, causou maior alteração de peso, estatisticamente significante para o Dyract (-2,55%/-1,72%) e para o Vitremer (-5,03%/-2,42%) comparados às RC Z250 (0,33%/0,20%), Durafill (0,17%/-0,18%) e Natural Flow (-0,14%/-0,17%).O CIVRM Vitremer apresentou as maiores alterações de rugosidade superficial (2,96 mm/1,59 mm) após imersão em suco de laranja e Coca-Cola, seguida de escovação. Houve correlação entre alteração de peso e rugosidade superficial / This study evaluated in vitro the effect of acidic beverages (orange juice, Coca-Cola soft drink, whisky) and toothbrushing upon restorative materials used in noncarious cervical lesions: one hybrid composite (Filtek Z250/3M), one microfill composite (Durafill VS/Heraeus Kulzer), one flow composite (Natural Flow/DFL), one compomer (Dyract/Dentsply) and one resin-modified glass ionomer (Vitremer/3M). Twenty standardized cylindrical specimens (10 mm in diameter and 4 mm thickness) of each material was made. In this research, measures of the changes in weight and roughness surface were carried out using a analytical scale and a rugosimeter, respectively. Five specimens of each material were immersed in test solutions for a 10-day period at a temperature of 37 °C. Distilled water was used like a control. After erosion, the specimens were submitted to 20,000 strokes of toothbrus hing using soft bristles tips and a slurry contained a 1:2 mixture of toothpaste and distilled water. The changes of weight was calculated by percentage corresponded of difference between initial and total weights (before and after erosion + toothbrusing). The changes of roughness was determined by difference between initial and total roughness (before and after erosion + toothbrushing). The data were analyzed using analysis of variance (ANOVA) and Tukey Test at level of p<0.05. The immersion in orange juice and Coca-Cola followed by toothbrushing caused higher changes of weight, statistically significant, for Dyract (-2.55%/-1.72%) and Vitremer (-5.03%/-2.42%) compared to Z250 (0.33%/0.20%), Durafill (0.17%/-0.18%) and Natural Flow (-0.14%/-0.17%). Vitremer presented the highest changes of surface roughness (2.96 mm/1.59 mm) after immersion in orange juice and Coca-Cola followed by toothbrushing. There was correlation between changes of weight and roughness.

Page generated in 0.2082 seconds